본문 바로가기
KERD
논문KCI 등재

우리나라의 구내 치근단 및 파노라마방사선촬영의 진단참고수준

Diagnostic reference levels for intraoral periapical and panoramic radiography

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective : The objective of this study was to suggest the diagnostic reference levels for intraoral and panoramic radiography through the nationwide survey at regular intervals in South Korea. Study Design : One hundred twenty-six dental institutions from all regions of South Korea were visited. Information on radiographic equipment and clinical exposure parameter was recorded at 118 intraoral and 125 panoramic equipment. Patient entrance dose (PED) and dose-area product (DAP) in intraoral radiography and DAP in panoramic radiography were measured using a DAP meter. Results : Third quartile PED and DAP of intraoral radiography in adults were 1.5 mGy and 46.0 mGy cm2 , those in 12-year-old children 1.2 mGy and 37.1 mGy cm2 and those in 6-year-old children 1.0 mGy and 29.9 mGy cm2 . Third quartile DAP of panoramic radiography in adults, 12, and 6-year-old children were 227 mGy cm2 , 175 mGy cm2 , 163 mGy cm2 , respectively. The median exposure parameters of intraoral radiography in adults were 60kV, 6mA, and 0.23 seconds and those in 12-year-old children 60kV, 6mA, and 0.16 seconds and those in 6-year-old children 60kV, 6mA, and 0.15 seconds. The median exposure parameters of panoramic radiography in adults were 74kV, 10mA, and 13.6 seconds and those in 12-yearold children 67kV, 10mA, and 13.2 seconds and those in 6-year-old children 67kV, 8mA, and 12.0 seconds. Conclusion : As the national DRLs for intraoral radiography and panoramic radiography in Korea, we recommended 1.5 mGy and 227 mGy cm2 for adults, 1.2 mGy and 175 mGy cm2 for 12-year-old children, and 1.0 mGy and 163 mGy cm2 for 6-year-old children, respectively

Abstract

Objective : The objective of this study was to suggest the diagnostic reference levels for intraoral and panoramic radiography through the nationwide survey at regular intervals in South Korea. Study Design : One hundred twenty-six dental institutions from all regions of South Korea were visited. Information on radiographic equipment and clinical exposure parameter was recorded at 118 intraoral and 125 panoramic equipment. Patient entrance dose (PED) and dose-area product (DAP) in intraoral radiography and DAP in panoramic radiography were measured using a DAP meter. Results : Third quartile PED and DAP of intraoral radiography in adults were 1.5 mGy and 46.0 mGy cm2 , those in 12-year-old children 1.2 mGy and 37.1 mGy cm2 and those in 6-year-old children 1.0 mGy and 29.9 mGy cm2 . Third quartile DAP of panoramic radiography in adults, 12, and 6-year-old children were 227 mGy cm2 , 175 mGy cm2 , 163 mGy cm2 , respectively. The median exposure parameters of intraoral radiography in adults were 60kV, 6mA, and 0.23 seconds and those in 12-year-old children 60kV, 6mA, and 0.16 seconds and those in 6-year-old children 60kV, 6mA, and 0.15 seconds. The median exposure parameters of panoramic radiography in adults were 74kV, 10mA, and 13.6 seconds and those in 12-yearold children 67kV, 10mA, and 13.2 seconds and those in 6-year-old children 67kV, 8mA, and 12.0 seconds. Conclusion : As the national DRLs for intraoral radiography and panoramic radiography in Korea, we recommended 1.5 mGy and 227 mGy cm2 for adults, 1.2 mGy and 175 mGy cm2 for 12-year-old children, and 1.0 mGy and 163 mGy cm2 for 6-year-old children, respectively

참고문헌 (18)

  1. 대한영상치의학교수협의회, "영상치의학" (2015), 나래출판사
  2. "The 2007 recommendations of the International Commission on Radiological Protection. ICRP Publication 103", Ann ICRP, 37(2-4), pp.125~132 (2007)
  3. Napier I, "Reference doses for dental radiography", Br Dental J, 186, pp.392~396 (1999)
  4. "요양기관종별 의료장비 현황"[URL]
  5. 치과X선 검사에서의 환자선량 권고량 마련을 위한 연구, "김은경", 식품의약품안전청, ~ (2009)
  6. 치과 파노라마 촬영에서의 연령별 환자선량 평가 및 가이드라인마련 연구, "김은경", 식품의약품안전청, ~ (2014)
  7. "HPA-RPD-029. Doses to patients from radiographic and fluoroscopi x-ray imaging procedures in the UK – 2005 review" (2007)[URL]
  8. "HPA-CRCE-034. Dose to patients from radiographic and fluoroscopic x-ray imaging procedures in the UK - 2010 review" (2012)[URL]
  9. "National DRLs for dental radiography. Guidance National Diagnostic Reference Levels: 22 January 2016 to 14 November 2018"[URL]
  10. Poppe B, "Radiation exposure and dose evaluation in intraoral dental radiology", Radiat Prot Dosimetry, 123, pp.262~267 (2007)
  11. "Radiation protection No. 180. Diagnostic reference levels in thirtysix european countries. Part 2/2" (2014)[URL]
  12. Helmrot E, "Measurement of radiation dose in dental radiology", Radiat Prot Dosimetry, 114, pp.168~171 (2005)
  13. Tierris CE, "Dose area product reference levels in dental panoramic radiology", Radiat Prot Dosimetry, 111, pp.283~287 (2004)
  14. "NCRP Report No. 172. Reference levels and achievable doses in medical and dental imaging: Recommendations for the United States" (2012)[URL]
  15. 김은경, "Diagnostic reference levels in intraoral dental radiography in Korea", Imaging Science in Dentistry, 42(4), pp.237~242 (2012), 대한영상치의학회
  16. 김은경, "성인과 소아에서 치과 파노라마방사선검사의 환자선량", 대한치과의사협회지, 55(8), pp.516~526 (2017), 대한치과의사협회[DOI]
  17. 환자 촬영종류별 진단참고수준 마련: 치과촬영장치(구내, 파노라마, Cone beam CT), "김은경", 질병관리본부, ~ (2019)
  18. 환자 촬영종류별 진단참고수준 마련 : 유방 및 일반촬영 12개 종류 추가, "도경현", 질병관리본부, ~ (2019)

관련 논문AI추천