본문 바로가기
KERD
논문KCI 등재

140 keV 감마선 차폐 시 납 차폐체 두께에 따른 깊이별 선량 평가

Shielding 140 keV Gamma Ray Evaluation of Dose by Depth According to Thickness of Lead Shield

1

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류방사선과학

초록

The present study made a phantom for gamma ray of 140 keV radiated from 99mTc, examined shielding effect of lead by thickness of the shielding material, and measured surface dose and depth dose by body depth. The OSL Nano Dot dosimeter was inserted at 0, 3, 15, 40, 90, and 180㎜ depths of the phantom, and when there was no shield, 0.2㎜ lead shield, 0.5㎜ lead shield, The depth dose was measured. Experimental results show that the total cumulative dose of dosimeters with depth is highest at 366.24 uSv without shield and lowest at 94.12 uSv with 0.5㎜ lead shield. The shielding effect of 0.2㎜ lead shielding was about 30.18% and the shielding effect of 0.5㎜ lead shielding was 74.30%, when the total sum of the accumulated doses of radiation dosimeter was 100%. The phantom depth and depth dose measurements showed the highest values at 0㎜ depth for all three experiments and the dose decreases as the depth increases. This study proved that the thicker a shielding material, the highest its shielding effect is against gamma ray of 140 keV. However, it was known that shielding material can't completely shield a body from gamma ray; it reached deep part of a human body. Aside from the International Commission on Radiation Units and Measurements (ICRU) recommending depth dose by 10㎜ in thickness, a plan is necessary for employees working in department of nuclear medicine where they deal with gamma ray, which is highly penetrable, to measure depth dose by body depth, which can help them manage exposed dose properly.

Abstract

The present study made a phantom for gamma ray of 140 keV radiated from 99mTc, examined shielding effect of lead by thickness of the shielding material, and measured surface dose and depth dose by body depth. The OSL Nano Dot dosimeter was inserted at 0, 3, 15, 40, 90, and 180㎜ depths of the phantom, and when there was no shield, 0.2㎜ lead shield, 0.5㎜ lead shield, The depth dose was measured. Experimental results show that the total cumulative dose of dosimeters with depth is highest at 366.24 uSv without shield and lowest at 94.12 uSv with 0.5㎜ lead shield. The shielding effect of 0.2㎜ lead shielding was about 30.18% and the shielding effect of 0.5㎜ lead shielding was 74.30%, when the total sum of the accumulated doses of radiation dosimeter was 100%. The phantom depth and depth dose measurements showed the highest values at 0㎜ depth for all three experiments and the dose decreases as the depth increases. This study proved that the thicker a shielding material, the highest its shielding effect is against gamma ray of 140 keV. However, it was known that shielding material can't completely shield a body from gamma ray; it reached deep part of a human body. Aside from the International Commission on Radiation Units and Measurements (ICRU) recommending depth dose by 10㎜ in thickness, a plan is necessary for employees working in department of nuclear medicine where they deal with gamma ray, which is highly penetrable, to measure depth dose by body depth, which can help them manage exposed dose properly.

참고문헌 (15)

  1. Shin GS, "Radiation Physics", pp.85~ (2004), Pyeonaem Hong
  2. 이왕희, "핵의학과 내 작업 환경에서 공기층 납치마의 피폭선량 감소 효과 평가", 한국콘텐츠학회 논문지, 14(12), pp.845~853 (2014), 한국콘텐츠학회[DOI]
  3. 이왕희, "광자극발광선량계와 열형광선량계를 이용한 핵의학과 선량 측정비교", 한국콘텐츠학회 논문지, 12(12), pp.329~334 (2012), 한국콘텐츠학회[DOI]
  4. Vetter RJ, "Medical health physics: a review", Health physics, 88(6), pp.653~664 (2008)
  5. 동경래, "방사선 취급 작업종사자의 개인 피폭선량(Individual Dose)에 관한 연구", 한국실내환경학회지, 6(1), pp.38~47 (2009), 한국실내환경학회
  6. Bag SO, "NUCLEAR MEDICINE SCIENCE", pp.44~46 (2014), Bomun Seoweon
  7. 장동근, "감마선 에너지에 따른 납치마의 차폐효과 분석", 방사선기술과학, 37(4), pp.247~252 (2014), 대한방사선과학회
  8. McCaffrey JP, "Radiation attenuation by lead and nonlead materials used in radiation shielding garments", Medical Physics, 34(2), pp.530~537 (2007)[DOI]
  9. 김선칠, "친환경 소재의 의료 방사선 차폐 시트 개발; Ⅱ: 바륨, 토르말린의 실리콘 폴리머 차폐 시트의 성능 평가", 방사선기술과학, 34(2), pp.141~147 (2011), 대한방사선과학회
  10. Nuclear safety, "Regulations on standards for reading registration and inspection" (2016)
  11. ICRU report 47. Measurement of Dose Equivalents from External Photon and Electron Radiations, , ~ (1992)
  12. 박명환, "X선 및 감마선에 대한 apron의 차폐율 측정", 방사선기술과학, 30(3), pp.245~250 (2007), 대한방사선과학회
  13. Kujala UM, "Physical loading and performance as predictors of back pain in healthy adults: A 5-year prospective study", European Journal of Applied Physiology and Occupational Physiology, 73(5), pp.452~458 (1996)[DOI]
  14. 최태진, "의료영상용 방사선방호를 위한 무납차폐체 개발", 의학물리, 21(2), pp.232~237 (2010), 한국의학물리학회
  15. 장동근, "몬테카를로 모의 모사를 이용한 핵의학과 방사선작업종사자의 손에 대한 피폭선량 분석", 방사선기술과학, 38(4), pp.477~482 (2015), 대한방사선과학회[DOI]

관련 논문AI추천