초록

Radiation is used for various purposes such as cancer therapy, research of industrial and drugs. However, in case of radiation accidents such as terrorism, collapsing nuclear plant by natural disasters like Fukushima in 2011, very high radiation does expose to human and could lead to death. For this reason, many people are concerning about radiation exposures. Therefore, assessment and research of retrospective radiation dose to human by various path is an necessary task to be continuously developed. Radiation exposure for workers in radiation fields can be generally measured using a personal exposure dosimeter such as TLD, OSLD. However, general people can’t be measured radiation doses when they are exposed to radiation. And even if radiation fields workers, when they do not in possession personal dosimeter, they also can’t be measured exposure dose immediately. In this study, we conduct retrospective research on reconstruction of dose after exposure by using smart chip card of personal items through Optically Stimulated Luminescence (OSL). The OSL signal of smart chip card shows linear response from 0.06 Gy to 15 Gy and results of fading rate 45 %, 48% for 24 and 48 hours due to the natural emission of radiation in sample, respectively. The minimum detectable limit (MDD) was 0.38 mGy. This values are expected to use as correction values for reconstruction of exposure dose.

Abstract

Radiation is used for various purposes such as cancer therapy, research of industrial and drugs. However, in case of radiation accidents such as terrorism, collapsing nuclear plant by natural disasters like Fukushima in 2011, very high radiation does expose to human and could lead to death. For this reason, many people are concerning about radiation exposures. Therefore, assessment and research of retrospective radiation dose to human by various path is an necessary task to be continuously developed. Radiation exposure for workers in radiation fields can be generally measured using a personal exposure dosimeter such as TLD, OSLD. However, general people can’t be measured radiation doses when they are exposed to radiation. And even if radiation fields workers, when they do not in possession personal dosimeter, they also can’t be measured exposure dose immediately. In this study, we conduct retrospective research on reconstruction of dose after exposure by using smart chip card of personal items through Optically Stimulated Luminescence (OSL). The OSL signal of smart chip card shows linear response from 0.06 Gy to 15 Gy and results of fading rate 45 %, 48% for 24 and 48 hours due to the natural emission of radiation in sample, respectively. The minimum detectable limit (MDD) was 0.38 mGy. This values are expected to use as correction values for reconstruction of exposure dose.

참고문헌 (15)

  1. Clemens W, "On the use of OSL of wire-bond chip card modules for retrospectiveandaccident dosimetry", Radiation Measurement, 44(5-6), pp.548~553 (2009)
  2. Murraya AS, "The single aliquot regenerative dose protocol: potential for improvements in reliability", Radiation Measurements, 37(4-5), pp.377~381 (2003)
  3. Lee JI, "On the use of new generation mobile phone (smart phone) for retrospective accident dosimetry", Radiation Physics and Chemistry, 116, pp.151~154 (2015)
  4. Trans Tech Publications Ltd, "Luminescence Related Phenomena and Their Applications: Special Topic Volume with Invited Peer Reviewed Papers Only" (2014), Trans tech publications
  5. Wintle AG, "Optically stimulated luminescence signals from quartz: A review", Radiation Measurements, 98, pp.10~33 (2017)
  6. 박정규, "형광유리 선량계와 광자극 발광선량계를 이용한 핵의학과 선량 측정비교", 방사선기술과학, 42(1), pp.47~51 (2019), 대한방사선과학회[DOI]
  7. Park SW, "Retrospective dose measurement using Optical Stimulated Luminescence (OSL) Characteristic of smart chip card for radiation accident", Conference of Korea Association For Radiation Protection, pp.394~395 (2017)
  8. Pradhan AS, "Use of OSL and TL of Electronic Components of Portable Devices for Retrospective Accident Dosimetry", Defect and Diffusion Forum, 347, pp.229~245 (2014)
  9. Mrozik A, "OSL signal of IC chips from mobile phones for dose assessment in accidental dosimetry", Radiation Measurement, 98, pp.1~9 (2017)
  10. Bøtter-Jensen L, "Review of optically stimulated luminescence (OSL) instrumental developments for retrospective dosimetry", Radiation Measurement, 45(3-6), pp.253~257 (2010)
  11. Bachev H, "Fkushima nuclear disaster – implications for Japanese agriculture and food chains" (2013), Munich Personal RePEc Archive
  12. 정미영, "CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과", 방사선기술과학, 32(3), pp.307~312 (2009), 대한방사선과학회
  13. Mathur VK, "Radiation sensitivity of memory chip module of an ID card", Radiation Measurement, 42(7), pp.43~48 (2007)
  14. Clemens W., "On the use of OSL of chip card modules with molding forretrospective and accident dosimetry", Radiation Measurement, 47(11), pp.1068~1073 (2012)
  15. Clemens W, "Radiation-induced damage analysed by luminescence methods in retrospective dosimetry and emergency response", Ann Ist Super Sanata, 45(3), pp.297~306 (2009)