핵의학과에서 99mTc를 이용한 방사성의약품의 투여율 측정 비교

Comparison of the Measurement of the Injection Rate of Radioactive Drugs Using 99mTc in Nuclear Medicine

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류방사선과학

초록

This study was conducted by SPECT test at the Department of Nuclear Medicine at Daegu P Hospital from June 1 to October 31, 2019. A 3-way injection material was mounted among inpatients, and a syringe that was administered with radiopharmaceuticals using a 99mTc labeled compound was secured. We tried to find a way to calculate the dose rate of each radiopharmaceutical and increase the dose rate. As a result of measuring the radioactivity of radiopharmaceuticals using 99mTc, the average dose rate of 60 syringes of all 6 radiopharmaceuticals was 93.26±7.34%, and the average dose rate of 99mTc-DMSA was 77.72%, 15.54% lower than the total. As a way to increase the dosing rate, the average dose rate diluted twice with the remaining amount of syringe after administration using normal saline increased to 95.37±6.99%, and the average dose rate diluted three times increased to 96.32±6.86%. The corresponding sample t-test to compare the pre- and post-dose rates at 1 dilution and 2 and 3 dilutions. As a result of the dilution and 2 dilutions, the probability of significance was 0.013, which was significantly higher than the dilution(p<0.05). The probability of significance for dilution 1 and dilution 3 was 0.016, which was significantly higher than in one dilution(p<0.05). The sum of the average dose rate using the experimental 3-way line was the highest with 98.85±1.42% of 99mTc, 99mTc-ECD 98.82±1.26%, 99mTc-Mebrofenin 98.82 ± 1.16%, 99mTc-HDP 98.74 ± 1.91%, 99mTc -MIBI was 98.69 ± 1.48%, and 99mTc-DMSA was the lowest with 86.47 ± 4.74%. When the number of dilutions was 5 times using 0.5 cc of normal saline and when the number of dilutions was 5 times using 1 cc of normal saline, when the number of dilutions was 5 times using 0.5 cc of normal saline and 1 cc of nomal saline When the number of dilutions was 5 times and the syringe volume was 0.5 cc, there was a statistically significant difference (p<0.05). There was a statistically significant difference when the number of dilutions was 5 times using 1 cc of nomal saline and the number of dilutions was 5 times using 1 cc of normal saline, and the syringe volume was 0.5 cc (p<0.05).

Abstract

This study was conducted by SPECT test at the Department of Nuclear Medicine at Daegu P Hospital from June 1 to October 31, 2019. A 3-way injection material was mounted among inpatients, and a syringe that was administered with radiopharmaceuticals using a 99mTc labeled compound was secured. We tried to find a way to calculate the dose rate of each radiopharmaceutical and increase the dose rate. As a result of measuring the radioactivity of radiopharmaceuticals using 99mTc, the average dose rate of 60 syringes of all 6 radiopharmaceuticals was 93.26±7.34%, and the average dose rate of 99mTc-DMSA was 77.72%, 15.54% lower than the total. As a way to increase the dosing rate, the average dose rate diluted twice with the remaining amount of syringe after administration using normal saline increased to 95.37±6.99%, and the average dose rate diluted three times increased to 96.32±6.86%. The corresponding sample t-test to compare the pre- and post-dose rates at 1 dilution and 2 and 3 dilutions. As a result of the dilution and 2 dilutions, the probability of significance was 0.013, which was significantly higher than the dilution(p<0.05). The probability of significance for dilution 1 and dilution 3 was 0.016, which was significantly higher than in one dilution(p<0.05). The sum of the average dose rate using the experimental 3-way line was the highest with 98.85±1.42% of 99mTc, 99mTc-ECD 98.82±1.26%, 99mTc-Mebrofenin 98.82 ± 1.16%, 99mTc-HDP 98.74 ± 1.91%, 99mTc -MIBI was 98.69 ± 1.48%, and 99mTc-DMSA was the lowest with 86.47 ± 4.74%. When the number of dilutions was 5 times using 0.5 cc of normal saline and when the number of dilutions was 5 times using 1 cc of normal saline, when the number of dilutions was 5 times using 0.5 cc of normal saline and 1 cc of nomal saline When the number of dilutions was 5 times and the syringe volume was 0.5 cc, there was a statistically significant difference (p<0.05). There was a statistically significant difference when the number of dilutions was 5 times using 1 cc of nomal saline and the number of dilutions was 5 times using 1 cc of normal saline, and the syringe volume was 0.5 cc (p<0.05).

참고문헌 (15)

  1. Chung JK, "Nuclear Medicine" (2008), Korea Medical Book publisher
  2. 김가중, "양전자 방출 핵종(^18F)의 감마에너지가 X선 CT영상에 미치는 영향", 한국산학기술학회논문지, 12(10), pp.4418~4424 (2011), 한국산학기술학회
  3. 선종률, "핵의학검사의 환자 유효선량 계산 프로그램 제작에 관한 연구", 한국산학기술학회논문지, 18(3), pp.657~665 (2017), 한국산학기술학회[DOI]
  4. 김정훈, "SPECT 영상을 사용한 기능적 심근형태의 자동 계측법 개발", 방사선기술과학, 35(2), pp.133~139 (2012), 대한방사선과학회[DOI]
  5. Choi DC, "Consideration of a bacteria contamination management in the dispensation of 99mTc radiopharmaceutical", Nuclear Medicine and Technology Society, 22(2), pp.84~87 (2018)
  6. James RB, "The Radiopharmacy A technologist's Guide", European Association of Nuclear Medicine, ~ (2008)
  7. Pandey AK, "Development of a radiopharmaceutical dose calculator for pediatric patients undergoing diagnostic nuclear medicine studies", Indian J Nucl Med, 28(2), pp.75~78 (2013)
  8. Treves ST, "Pediatric Nuclear Medicine" (1995), Springer-Verlag
  9. Pandey AK, "Development of a radiopharmaceutical dose calculator for pediatric patients undergoing diagnostic nuclear medicine studies", Indian J Nucl Med, 28(2), pp.75~78 (2013)
  10. Treves ST, "Pediatric Nuclear Medicine" (1995), Springer-Verlag
  11. Galbraith W, "Assessment of 99mTc-succimer residual activity using inert nonreactive syringes", Journal of Nuclear Medicine Technology, 43(1), pp.61~63 (2015)
  12. Bauwens M, "Retention of 99mTc-DMSA(III)and 99mTc-nanocolloid in different syringes affects imaging quality", Nuclear Medicine Communications, 35(4), pp.433~437 (2014)
  13. Go CS, "Nuclear medicine" (2013), Korea medicine
  14. 길종원, "핵의학검사의 방사성의약품 소아투여량 공식 별 투여량 및 유효선량 비교", 한국융합학회논문지, 8(8), pp.147~154 (2017), 한국융합학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (7건)