핵의학과 PET/CT실 방사선작업종사자의 수정체 부위의 등가선량과 흉부의 유효선량의 측정 비교
Comparison of the Equivalent Dose of the Lens Part and the Effective Dose of the Chest in the PET/CT Radiation Workers in the Nuclear Medicine Department
0
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Comparison of the effective dose of the chest and the equivalent dose of the lens site in the radiation workers working at four medical institutions with the PET / CT room located in one metropolitan city and province from April 1 to June 30, 2018 Respectively. Radioactive medicine were measured at the time of dispensing and at the time of injection. In this experiment, the average dispensing time per patient was 5.7 minutes and the average injection time was 3.1 minutes. The equivalent dose at the lens site was 0.78 μSv/h for 1 mCi, and the effective dose for chest was 0.18 μ Sv/h per 1 mCi. The equivalent dose at the lens site during injection was 0.88 μSv/h per mCi and the effective dose of chest was 0.20 μSv/h per mCi. The daily effective dose of the chest was 0.9±0.6 μSv and the equivalent dose of the lens site was 3.6±1.4 μSv during daily dosing for 20 days. The effective dose of the chest during the day was 0.6±0.5 μSv and the equivalent dose of the lens was 2.2±1.0 μSv. At the time of dispensing, the equivalent dose of the lens was 0.187±0.035 mSv, the effective dose of the chest was 0.137±0.055 mSv, the equivalent dose of the lens was 0.247±0.057 mSv, and the effective dose of the monthly chest was 0.187±0.021 mSv. As a result of the corresponding sample test, the equivalent dose and the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, The equivalent dose of the lens and the effective dose of the chest were statistically significant (p<0.05) with a significance of 0.000. However, there was no statistically significant difference (p>0.05) between the equivalent dose and the effective dose of the chest, the equivalent dose of the lens at the time of injection, and the effective dose of the chest at 0.138 and 0.230, respectively.
Abstract
Comparison of the effective dose of the chest and the equivalent dose of the lens site in the radiation workers working at four medical institutions with the PET / CT room located in one metropolitan city and province from April 1 to June 30, 2018 Respectively. Radioactive medicine were measured at the time of dispensing and at the time of injection. In this experiment, the average dispensing time per patient was 5.7 minutes and the average injection time was 3.1 minutes. The equivalent dose at the lens site was 0.78 μSv/h for 1 mCi, and the effective dose for chest was 0.18 μ Sv/h per 1 mCi. The equivalent dose at the lens site during injection was 0.88 μSv/h per mCi and the effective dose of chest was 0.20 μSv/h per mCi. The daily effective dose of the chest was 0.9±0.6 μSv and the equivalent dose of the lens site was 3.6±1.4 μSv during daily dosing for 20 days. The effective dose of the chest during the day was 0.6±0.5 μSv and the equivalent dose of the lens was 2.2±1.0 μSv. At the time of dispensing, the equivalent dose of the lens was 0.187±0.035 mSv, the effective dose of the chest was 0.137±0.055 mSv, the equivalent dose of the lens was 0.247±0.057 mSv, and the effective dose of the monthly chest was 0.187±0.021 mSv. As a result of the corresponding sample test, the equivalent dose and the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, the effective dose of the chest, The equivalent dose of the lens and the effective dose of the chest were statistically significant (p<0.05) with a significance of 0.000. However, there was no statistically significant difference (p>0.05) between the equivalent dose and the effective dose of the chest, the equivalent dose of the lens at the time of injection, and the effective dose of the chest at 0.138 and 0.230, respectively.
참고문헌 (15)
- 박훈희, "A Study of Decrease Exposure Dose for the Radiotechnologist in PET", CT, 2015, pp.38(1), 23~30[DOI]
- 신규설, "PET-CT에서 CT의 관전압 및 관전류에 따른 SUV값의 변화", 방사선기술과학, 30(4), pp.373~379 (2007), 대한방사선과학회
- Park SK, "The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in 18F-FDG Wholebody PET", The Korean Journal of Nuclear Medicine Technology, 14(2), pp.100~103 (2010)
- 박준철, "핵의학 종사자에서 손 부위의 외부 피폭선량 연구", 방사선기술과학, 35(2), pp.141~149 (2012), 대한방사선과학회[DOI]
- Kang BS, "Radiation Health Management", ~ (2009)
- Song HJ, "Dose evaluation of nuclear medicine radiation workers using electronic dosimeter", master’s, pp.2017
- Lee JG, "ICRP Publications 103", International Radiation Protection Committee, ~ (2008)
- Jang KH, "Dose management at medical institutions", Medical Radiation Safety Symposium (2013)
- Korea Nuclear Cooperation Foundation, "Analysis and evaluation technology of radiation protection system at home and abroad", ~ (2011)
- International Atomic Energy Agency, "Radiation protection and safety of radiation sources international basic safety standards", General Safety Requirements Part 3, ~ (2011)
- ICRP Statement on tissue reactions and early and late effects of radiation in normal tissues and organs-threshold doses for tissue reactions in a radiation protection context, "Clement CH", ICRP Publication, ~ (2012)
- 김문규, "X-ray를 이용한 경부 피부에서 경막외강까지의 깊이 예측", Anesthesia and Pain Medicine, 12(1), pp.68~71 (2017), 대한마취통증의학회
- 김민정, "통증 치료에서의 방사선 노출에 의한 눈의 영향과 보호", Anesthesia and Pain Medicine, 12(4), pp.297~305 (2017), 대한마취통증의학회
- 김태우, "광자와 전자 방사선에 대한 수정체 감시 실용량의 적합성 평가", 석사, 원자력공학과, pp.2014
- 류영환, "핵의학과 방사선작업종사자의 말단 및 수정체 선량에 대한 인식도 조사", 공학기술논문지, 8(3), pp.211~217 (2015), 공학기술연구원[DOI]