This study was conducted to reduce the exposure dose to the breast and adjacent organs as the number of Mammography increased. Therefore, it has been designed a shield in lead, bismuth + tungsten, and bismuth that does not require to be equipped by the patient, in which each type of shield was compared and analyzed of radiation exposure dose to breast, thyroid, and eye. Using a mammography machine, optically stimulated luminescent dosimeter( OSLD) was inserted to bilateral breast, thyroid, and eye of a dosimetry phantom to measure dose radiated onto the phantom. Shielding device was made in different thickness of 2mm, 3mm, and 5mm and dose evaluation was performed by measuring the dose while using lead, bismuth, and bismuth + tungsten prosthesis. When each shields combined with shielding device, were compared of dose, all showed similar does reduction in the dose to breast, thyroid, and eye in both cranialcaudal and mediolateraloblique view. Based on the current study, bismuth and bismuth + tungsten can replace conventional lead shield and it is anticipated to safely and conveniently reduce radiation exposure to breast, thyroid, and eye with the shield that does not require to be equipped.
Abstract
This study was conducted to reduce the exposure dose to the breast and adjacent organs as the number of Mammography increased. Therefore, it has been designed a shield in lead, bismuth + tungsten, and bismuth that does not require to be equipped by the patient, in which each type of shield was compared and analyzed of radiation exposure dose to breast, thyroid, and eye. Using a mammography machine, optically stimulated luminescent dosimeter( OSLD) was inserted to bilateral breast, thyroid, and eye of a dosimetry phantom to measure dose radiated onto the phantom. Shielding device was made in different thickness of 2mm, 3mm, and 5mm and dose evaluation was performed by measuring the dose while using lead, bismuth, and bismuth + tungsten prosthesis. When each shields combined with shielding device, were compared of dose, all showed similar does reduction in the dose to breast, thyroid, and eye in both cranialcaudal and mediolateraloblique view. Based on the current study, bismuth and bismuth + tungsten can replace conventional lead shield and it is anticipated to safely and conveniently reduce radiation exposure to breast, thyroid, and eye with the shield that does not require to be equipped.
참고문헌 (14)
- Yoo KY, "National guidelines for breast cancer screening", J Korean Med Assoc, 45(8), pp.992~1004 (2002)
- ICRP, "The 2007 Recommendations of the international commission on radiological protection: ICRP Publication 103", Ann. ICRP, 37, pp.2~4 (2007)
- 조용인, "유방 X선 검사 시 몬테카를로 시뮬레이션을 이용한 3D 프린팅 차폐재료의 효용성 평가", 한국방사선학회논문지, 14(3), pp.295~301 (2020), 한국방사선학회[DOI]
- 박훈희, "비스무스, 텅스텐 기반 차폐체의 성능 및 유용성 평가", 방사선기술과학, 41(6), pp.611~616 (2018), 대한방사선과학회[DOI]
- 정미영, "CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과", 방사선기술과학, 32(3), pp.307~312 (2009), 대한방사선과학회
- 최우전, "Brain CT검사 시 3D프린터 필라멘트에 따른 수정체 차폐 연구", 한국방사선학회논문지, 15(2), pp.101~108 (2021), 한국방사선학회[DOI]
- Sechopoulos I, "Mammography and the risk of thyroid cancer", American Journal of Roentgenology, 198(3), pp.705~707 (2012)
- 구본열, "유방X선촬영 시 피폭선량 감소를 위한 유방촬영용 차폐복의 유용성에 관한 연구", 방사선기술과학, 42(2), pp.99~104 (2019), 대한방사선과학회
- 홍은애, "유방촬영 시 갑상샘의 피폭선량 경감을 위한 Al Face Block 제작 및 유용성에 관한 연구", 방사선기술과학, 36(1), pp.11~17 (2013), 대한방사선과학회
- Clement CH, "Radiological protection in fluoroscopically guided procedures performed outside the imaging department", Annals of the ICRP, 40(6), pp.1~102 (2010)
- Kim HS, "Radiography imaging", pp.492~500 (2009), Daihaks
- Kang BS, "Radiation therapy", pp.161~171 (2010), Daihaks
- 김동식, "유착태반환자의 예방적 내장골동맥 풍선카테터 설치술 시행 시 태아선량 평가", 방사선기술과학, 39(3), pp.313~321 (2016), 대한방사선과학회[DOI]
- "ATOM Dosimetry phantoms Models 701 – 706", CIRS, 4~ (2013)