This study aimed to evaluate the impact of changes in beam arrangement and arc counts on dosimetric factors in volumetric modulated arc therapy (VMAT) inverse radiation therapy planning for hippocampal-avoidance whole brain radiation therapy (HA-WBRT) by using the Elekta Monaco radiation therapy planning system (RTPs). For coplanar VMAT, both the arc per beam (APB) method and the beam determined arc(BDA) method, which is determined by the number of beams, were applied. For non-coplanar VMAT, the BDA method was utilized, and a total of 9 treatment plans were established by varying the arc counts. All radiation therapy plans met the radiation oncology group (RTOG) 0933 protocol standards, and 14 dosimetric factors were compared and analyzed. The results showed that the BDA-NC VMAT method demonstrated superior performance in terms of planning target volume (PTV) coverage and protection of normal organs, while APB-VMAT was advantageous in terms of hippocampal protection, monitor unit and delivery time. This study is expected to contribute to the efficient establishment of HA-WBRT plans considering the changes in beam arrangement and rotation arc numbers in Monaco RTPs.

Abstract

This study aimed to evaluate the impact of changes in beam arrangement and arc counts on dosimetric factors in volumetric modulated arc therapy (VMAT) inverse radiation therapy planning for hippocampal-avoidance whole brain radiation therapy (HA-WBRT) by using the Elekta Monaco radiation therapy planning system (RTPs). For coplanar VMAT, both the arc per beam (APB) method and the beam determined arc(BDA) method, which is determined by the number of beams, were applied. For non-coplanar VMAT, the BDA method was utilized, and a total of 9 treatment plans were established by varying the arc counts. All radiation therapy plans met the radiation oncology group (RTOG) 0933 protocol standards, and 14 dosimetric factors were compared and analyzed. The results showed that the BDA-NC VMAT method demonstrated superior performance in terms of planning target volume (PTV) coverage and protection of normal organs, while APB-VMAT was advantageous in terms of hippocampal protection, monitor unit and delivery time. This study is expected to contribute to the efficient establishment of HA-WBRT plans considering the changes in beam arrangement and rotation arc numbers in Monaco RTPs.

참고문헌 (21)

  1. de Ruiter MB, "Hippocampal avoidance prophylactic cranial irradiation(HA-PCI)for small cell lung cancer reduces hippocampal atrophy compared to conventional PCI", Neuro-oncology, 25(1), pp.167~176 (2023)[DOI]
  2. Chiang PY, "Hippocampal-sparing whole-brain radiotherapy under coplanar or noncoplanar VMAT", Medical Dosimetry, 48(3), pp.134~139 (2023)[DOI]
  3. Aijun J, "Dosimetric evaluation of four whole brain radiation therapy approaches with hippocampus and inner ear avoidance and simultaneous integrated boost for limited brain metastases", Radiation Oncology, 14(1), pp.1~8 (2019)[DOI]
  4. Alejandro P, "Dosimetric comparison of four volumetric-modulated arc therapy beam arrangements utilized for hippocampal-sparing whole-brain radiation therapy", Journal of Medical Physics, 44(1), pp.1~8 (2019)[DOI]
  5. Trifiletti DM, "The role of whole-brain radiation therapy in patients with cerebral metastases", Cancer, 124(10), pp.2072~2074 (2018)[DOI]
  6. Lee YW, "Whole brain radiation-induced cognitive impairment : pathophysiological mechanisms and therapeutic targets", Biomolecules & Therapeutics, 20(4), pp.357~370 (2012)[DOI]
  7. Kim SH, "Functional neuroanatomy of learning and memory", The Korean Journal of Sychopathology, 8(1), pp.22~34 (1999)
  8. Xue J, "A simplified non-coplanar volumetric modulated arc therapy for the whole brain radiotherapy with hippocampus avoidance", Frontiers in Oncology, 13, pp.1143564~ (2023)[DOI]
  9. Yuen AHL, "Volumetric modulated arc therapy(VMAT)for hippocampalavoidance whole brain radiation therapy : Planning comparison with Dual-arc and Split-arc partial-field techniques", Radiation Oncology, 15(1), pp.1~10 (2020)[DOI]
  10. Hogstrom KR, "Review of electron beam therapy physics", Physics in Medicine and Biology, 51(13), pp.R455~R89 (2006)[DOI]
  11. Brown PD, "Hippocampal avoidance during whole-brain radiotherapy plus memantine for patients with brain metastases : Phase III trial NRG oncology CC001", Journal of Clinical Oncology, 38(10), pp.1019~1029 (2020)[DOI]
  12. Gondi V, "Preservation of memory with conformal avoidance of the hippocampal neural stem-cell compartment during whole-brain radiotherapy for brain metastases(RTOG 0933) : A phase II multi-institutional trial", Journal of Clinical Oncology, 32(34), pp.3810~3816 (2014)[DOI]
  13. Kazda T, "Why and how to spare the hippocampus during brain radiotherapy : The developing role of hippocampal avoidance in cranial radiotherapy", Radiation Oncology, 9(1), pp.1~22 (2014)[DOI]
  14. Grosu AL, "Whole-brain irradiation with hippocampal sparing and dose escalation on metastases : Neurocognitive testing and biological imaging(HIPPORAD)-A phase II prospective randomized multicenter trial(NOA-14, ARO 2015-3, DKTK-ROG)", BMC Cancer, 20(1), pp.1~13 (2020)[DOI]
  15. Nevelsky A, "Hippocampal-sparing whole-brain radiotherapy using the elekta equipment", J Appl Clin Med Phys, 14(3), pp.113~120 (2013)[DOI]
  16. Yuen AHL, "Hybrid split-arc partial-field volumetric modulated arc therapy : an improved beam arrangement for linear accelerator-based hippocampal-avoidance whole brain radiation therapy", Reports of Practical Oncology and Radiotherapy, 27(2), pp.352~359 (2022)[DOI]
  17. Kalet AM, "Dosimetric comparison of single-beam multi-arc and 2-beam multi-arc VMAT optimization in the Monaco treatment planning system", Preprint, 42(2), pp.122~125 (2017)[DOI]
  18. Pudsey LM, "The use of collimator angle optimization and jaw tracking for VMAT-based singleisocenter multiple-target stereotactic radiosurgery for up to six targets in the Varian Eclipse treatment planning system", J Appl Clin Med Phys, 22(9), pp.171~182 (2021)[DOI]
  19. Guckenberger M, "Is a single arc sufficient in volumetric-modulated arc therapy(VMAT)for complex-shaped target volumes?", Radiotherapy and Oncology, 93(2), pp.259~265 (2009)[DOI]
  20. Chang DS, "Therapeutic ratio", Basic Radiotherapy Physics and Biology, pp.307~312 (2021)[DOI]
  21. Shen J, "An efficient Volumetric Arc Therapy treatment planning approach for hippocampalavoidance whole-brain radiation therapy(HA-WBRT)", Preprint, 40(3), pp.205~209 (2015)[DOI]

관련 논문AI추천

용적변조회전 방사선치료 시 Set-up 오차에 따른선량 전달 정확성의 평가김상현, 나권우, 박성아, 이주훈, 하광은(사)한국방사선산업학회 · 방사선산업학회지2018 · 제12권 제1호Dummy Run of Quality Assurance Program before Prospective Study of Hippocampus-Sparing Whole-Brain Radiotherapy and Simultaneous Integrated Boost for Multiple Brain Metastases from Non-small Cell Lung Cancer: Korean Radiation Oncology Group (KROG) 17-06 Study강민규, 김연실, 김영석, 김진희, 노오규, 노재명, 박우윤, 박재원, 서양권, 설기호, 안용찬, 우홍균, 이규찬, 이동수, 이정애, 이지혜, 정원구, 정은아, 조선미대한암학회 · Cancer Research and Treatment2019 · 제51권 제3호두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향김가중, 백금문, 엄기천대한방사선과학회 · Journal of Radiological Science and Technology2023 · 제46권 제3호비 인두암 체적 조절 호형 방사선 치료의 선량 계산 격자 크기에 따른 선량 체적 지수와 방사선 생물학적 지수의 평가강동진, 민정환, 박소현, 신영주, 심재구, 정재용대한방사선과학회 · Journal of Radiological Science and Technology2020 · 제43권 제4호Verification of Low Risk for Perihippocampal Recurrence in Patients with Brain Metastases Who Received Whole-Brain Radiotherapy with Hippocampal Avoidance강대규, 김성환, 김영경, 이종훈대한암학회 · Cancer Research and Treatment2019 · 제51권 제2호Dosimetry study comparing single-isocenter high-definition dynamic radiosurgery with multiple-isocenter cone-based stereotactic radiosurgery in treating multiple brain metastasesJi Tianlong, Li Guang, Song Yaowen한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제3호

이 간행물의 다른 논문 (5건)