Experience of Reticulocytes Measurement at 720 nm Using Spectrophotometer
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Currently, reticulocyte experimental calculation technology used in clinical laboratories are divided two types: manual and automated. Manual reticulocyte counting using a microscopy lacks accuracy due particularly to its low reproducibility, affecting the accuracy of manual reticulocyte count. Moreover, Automatic blood corpuscle analyzer flow cytometry is difficult to be used in underdeveloped countries and small scale laboratories due to relatively high cost. Therefore, this study tried to find a new method to complement these drawbacks. The aim of this study was to compare the stained reticulocytes count by spectrophotometer and also to analyze the statistics of spectrophotometer and flow cytometer. The same 8 EDTA samples were repeated 36 times to compare the agreement between spectrophotometer and flow cytometer. This study measured the specimen diluted 600 times at 700∼780 nm by 10 differences. Wavelength between 710 to 730 by absorbance showed a positive correlation between standard data and test data (r=0.967, p<0.01), presenting a correlation between variables. Statistical analyses of regression for test and standard parametric data, the optimal dilution factor was 600 times. Therefore, this study tried to technical utilizes such as contributing economical for the reticulocyte absorbance apply from the auto spectrophotometer, a monitoring system for the reticulocyte relation anemia, etc. Therefore, more extensive studies, including an auto chemical analyzer application, will be needed.
Abstract
Currently, reticulocyte experimental calculation technology used in clinical laboratories are divided two types: manual and automated. Manual reticulocyte counting using a microscopy lacks accuracy due particularly to its low reproducibility, affecting the accuracy of manual reticulocyte count. Moreover, Automatic blood corpuscle analyzer flow cytometry is difficult to be used in underdeveloped countries and small scale laboratories due to relatively high cost. Therefore, this study tried to find a new method to complement these drawbacks. The aim of this study was to compare the stained reticulocytes count by spectrophotometer and also to analyze the statistics of spectrophotometer and flow cytometer. The same 8 EDTA samples were repeated 36 times to compare the agreement between spectrophotometer and flow cytometer. This study measured the specimen diluted 600 times at 700∼780 nm by 10 differences. Wavelength between 710 to 730 by absorbance showed a positive correlation between standard data and test data (r=0.967, p<0.01), presenting a correlation between variables. Statistical analyses of regression for test and standard parametric data, the optimal dilution factor was 600 times. Therefore, this study tried to technical utilizes such as contributing economical for the reticulocyte absorbance apply from the auto spectrophotometer, a monitoring system for the reticulocyte relation anemia, etc. Therefore, more extensive studies, including an auto chemical analyzer application, will be needed.
참고문헌 (17)
- Sherwood L, "Animal physiology" (2005), Cengage Learning
- Riley RS, "Reticulocyte enumeration:past & present", Lab Med, 32(10), pp.599~608 (2001)
- Piva E, "Automated reticulocyte counting: State of the art and clinical applications in the evaluation of erythropoiesis", Clin Chem Lab Med, 48(10), pp.1369~1380 (2010)
- Wintrobe MM, "Wintrobe's clinical hematology" (2009), Lippincott Williams & Wilkins
- Lewis SM, "Dacie and Lewis practical hematology" (2006), Churchill Livingstone
- 최미옥, "XE-2100을 이용한 망상적혈구수와 미성숙망상적혈구 분획의 측정", 대한임상검사과학회지, 32(3), pp.14~19 (2000), 대한임상검사과학회
- Sage BH, "A rapid, vital staining procedure for flow cytometric analysis of human reticulocytes", Cytometry Part A, 4(3), pp.222~227 (1983)
- 신수, "ADVIA 120을 이용한 망성적혈구 분석항목의 참고치", Annals of Laboratory Medicine, 23(1), pp.6~11 (2003), 대한진단검사의학회
- Managoli N, "Limited role of platelet transfusion in dengue management and the value of reticulocyte production index as a measure of clinical improvement", International Journal of Scientific Study, 4(12), pp.187~191 (2017)
- Scherer PS, "New red blood cell and reticulocyte parameters and reference values for healthy individuals and in chronic kidney disease", J Bras Path Med Lab, 51(2), pp.77~84 (2015)
- Chieko Takagi, "Higher reticulocyte counts are associated with higher mortality rates in hemodialysis patients: a retrospective single-center cohort study", Renal Replacement Therapy, 3(1), pp.4~ (2017), Springer Nature[DOI]
- Savage RA, "Analytic inaccuracy and imprecision in reticulocyte counting: a preliminary report from the college of american pathologists reticulocyte project", Blood Cells, 11(1), pp.97~112 (1984)
- Lee LG, "Thiazole Orange, a new dye for reticulocyte analysis", cytometry, 7(6), pp.508~517 (1986)
- 서숙원, "골수이식 후 미성숙 망상적혈구의 유용성 평가", 대한임상검사과학회지, 36(1), pp.27~32 (2004), 대한임상검사과학회
- Lee WC, "Giemsa-stained wet mount based method for reticulocyte quantification: a viable alternative in resource limited or malaria endemic settings", PloS one, 8(4), pp.e60303~ (2013)
- "Spectrophotometry" (2009)[URL]
- Ibrahim SF, "Flow cytometry and cell sorting", Adv Biochem Eng Biotechnol, 106, pp.19~39 (2007)