Scoring System for Detecting Spurious Hemolysis in Anticoagulated Blood Specimens
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Background: The identification of in vitro hemolysis (IVH) using a hematology analyzer is challenging because centrifugation of the specimens cannot be performed for cell counts. In the present study, we aimed to develop a scoring system to help identify the presence of hemolysis in anticoagulated blood specimens. Methods: Thirty-seven potassium EDTA anticoagulated blood specimens were obtained, and each specimen was divided into 3 aliquots (A, B, and C). Aliquots B and C were mechanically hemolyzed by aspirating 2 and 5 times, respectively, using a 27-gauge needle and then tested; aliquot A was analyzed immediately without any hemolysis. After the cells were counted, aliquots B and C were centrifuged and the supernatants were tested for the hemolytic index and lactate dehydrogenase levels. Results: The 4 hematologic parameters were selected and scored from 0 to 3 as follows:<34.0, 34.0-36.2, 36.3-38.4, and ≥38.5 for mean cell hemoglobin concentration (MCHC, g/dL); <0.02, 0.02, 0.03, and ≥0.04 for red blood cell ghosts (1012/L); <0.13, 0.13-0.38, 0.39-1.30, and ≥1.31 for difference value (g/dL) of measured hemoglobin and calculated hemoglobin; and <0.26, 0.26-0.95, 0.96-3.34, and ≥3.35 for difference value (g/dL) of MCHC and cell hemoglobin concentration mean. The hemolysis score was calculated by adding all the scores from the 4 parameters. At the cutoff hemolysis score of 3, the IVH of aliquots B and C were detected as 64.9% and 91.9%, respectively. Conclusions: The scoring system might provide effective screening for detecting spurious IVH.
Abstract
Background: The identification of in vitro hemolysis (IVH) using a hematology analyzer is challenging because centrifugation of the specimens cannot be performed for cell counts. In the present study, we aimed to develop a scoring system to help identify the presence of hemolysis in anticoagulated blood specimens. Methods: Thirty-seven potassium EDTA anticoagulated blood specimens were obtained, and each specimen was divided into 3 aliquots (A, B, and C). Aliquots B and C were mechanically hemolyzed by aspirating 2 and 5 times, respectively, using a 27-gauge needle and then tested; aliquot A was analyzed immediately without any hemolysis. After the cells were counted, aliquots B and C were centrifuged and the supernatants were tested for the hemolytic index and lactate dehydrogenase levels. Results: The 4 hematologic parameters were selected and scored from 0 to 3 as follows:<34.0, 34.0-36.2, 36.3-38.4, and ≥38.5 for mean cell hemoglobin concentration (MCHC, g/dL); <0.02, 0.02, 0.03, and ≥0.04 for red blood cell ghosts (1012/L); <0.13, 0.13-0.38, 0.39-1.30, and ≥1.31 for difference value (g/dL) of measured hemoglobin and calculated hemoglobin; and <0.26, 0.26-0.95, 0.96-3.34, and ≥3.35 for difference value (g/dL) of MCHC and cell hemoglobin concentration mean. The hemolysis score was calculated by adding all the scores from the 4 parameters. At the cutoff hemolysis score of 3, the IVH of aliquots B and C were detected as 64.9% and 91.9%, respectively. Conclusions: The scoring system might provide effective screening for detecting spurious IVH.
참고문헌 (7)
- Clinical Laboratory and Standards Institute, "Hemolysis, icterus, and lipemia", turbidity indices as indicators of interference in clinical laboratory analysis. Approved guideline, C56-A, 2012
- 신동훈, "Development of an Integrated Reporting System for Verifying Hemolysis, Icterus, and Lipemia in Clinical Chemistry Results", Annals of Laboratory Medicine, 34(4), pp.307~312 (2014), 대한진단검사의학회
- Lippi G, "Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories", Crit Rev Clin Lab Sci, 48, pp.143~153 (2011)
- Vajpayee N, "Clinical diagnosis and management by laboratory methods", pp.509~535 (2011), WB Saunders
- Kunicka J, "Automated quantitation of hemoglobin-based blood substitutes in whole blood samples", Am J Clin Pathol, 116, pp.913~919 (2001)
- "ADVIA 2120", 2120i hematology systems operator’s guide, 2010
- Lippi G, "Identification of spurious hemolysis in anticoagulated blood with Sysmex XE-2100 and Siemens Advia 2120", Clin Lab, 58, pp.801~804 (2012)