본문 바로가기
KERD
논문KCI 등재

실시간 박테리아 감지를 위한 정전용량방식의 MEMS 바이오센서

MEMS based capacitive biosensor for real time detection of bacterial growth

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

A biosensor based on the measurement of capacitance changes has been designed and fabricated for simple and real-time detection of bacteria. Compared to an impedance measurement technique, the capacitance measurement can makeadditional measurement circuits simpler, which improves a compatability for integration between the sensor and circuit.The fabricated sensor was characterized by detecting Escherichia coli(E. coli). The capacitance changes measured by thesensor were proportional to E. coli cell density, and the proposed sensor could detect 1×106 cfu/ml E. coli at least. Thereal-time detection was verified by measuring the capacitance every 20 minutes. After 7 hours of E. coli growthexperiment, the capacitance of the sensor in the micro volume well with 4.5×105 cfu/ml of initial E. coli density increasedby 20 pF, and that in another wells with 1.5×106 cfu/ml and 8.5×107 cfu/ml initial E. coli density increased by 56 pFand 71 pF, respectively. The proposed sensor has a possibility of the real-time detection for bacterial growth, and candetect E. coli cels with 1.8×105 cfu in nutrient broth in 5 hours.

Abstract

A biosensor based on the measurement of capacitance changes has been designed and fabricated for simple and real-time detection of bacteria. Compared to an impedance measurement technique, the capacitance measurement can makeadditional measurement circuits simpler, which improves a compatability for integration between the sensor and circuit.The fabricated sensor was characterized by detecting Escherichia coli(E. coli). The capacitance changes measured by thesensor were proportional to E. coli cell density, and the proposed sensor could detect 1×106 cfu/ml E. coli at least. Thereal-time detection was verified by measuring the capacitance every 20 minutes. After 7 hours of E. coli growthexperiment, the capacitance of the sensor in the micro volume well with 4.5×105 cfu/ml of initial E. coli density increasedby 20 pF, and that in another wells with 1.5×106 cfu/ml and 8.5×107 cfu/ml initial E. coli density increased by 56 pFand 71 pF, respectively. The proposed sensor has a possibility of the real-time detection for bacterial growth, and candetect E. coli cels with 1.8×105 cfu in nutrient broth in 5 hours.

참고문헌 (16)

  1. P. S. Mead, "Food-related illness and death in the United Stated", Emerg. Infect. Dis, 5, pp.607~625 (1999)
  2. S. J. Olsen, "Surveillance for foodbornedisease outbreaks -United States, 1993-1997", MMWR, 49(ss-1) (2000)
  3. K. Inque, "Evaluation of L-pyrrolidonyl peptidase paper strip test for differentiation of members of the family enterobacteriaceae, particularly salmonella spp", J. Clin. Microbiol, 34(7), pp.1811~1812 (1996)
  4. I. Abdel-Hamid, "Flow-through immunofiltration assay system for rapid detection of E. coli O157:H7", Biosens. Bioelectron, 14(3), pp.309~316 (1999)
  5. M. A. Yoshimasu, "Application of rapid dot blot immunoassay for detection of sal-monella enterica serovar enteritidis in eggs, Poultry, and other foods", Appl. Environ. Microbiol, 67(1), pp.459~461 (2001)
  6. M. Dahlenborg, "Development of a combined selection and enrichment pcr procedure for clostridium botulinum types B, E, and F and its use to determine prevalence in fecal samples from slaughtered pigs", Appl. Environ. Microbiol, 67(10), pp.4781~4788 (2001)
  7. A. Klausegger, "Gram type-specific broad-range PCR amplification for rapid detection of 62 pathogenic bacteria", J. Clin. Microbiol, 37(2), pp.464~466 (1999)
  8. H. O. Fatoyinbo, "An integrated dielectrophoretic quartz crystal microbalance (DEP-QCM) device for rapid biosensing applications", Biosens. Bioelectron, 23, pp.225~232 (2007)
  9. S. I. Kim, "Chemical and biosensors; QCM biosensor for the determination of haptoglobin", J. Kor. Sensors Society, 16(2), pp.132~141 (2007)
  10. B. Nguyen, "Biosensor-surface plasmon resonance :Quantitative analysis of small molecule-nucleic acid interactions", Methods, 42, pp.150~161 (2007)
  11. J. H. Jung, "Chemical and biosensors; Design of multi-layered surface plasmon resonance sensors using optical admittance method and evolution algorithm", J. Kor. Sensors Society, 14(6), pp.402~408 (2005)
  12. P.A. Noble, "Hypothetical model for monitoring microbial growth by using capacitance measurements - a minireview", J. Microbiol. Meth, 37(1), pp.45~49 (1999)
  13. J. Owicji, "Biosensors based on the energy metabolism of living cells: The physical chemistry and cell biology of extracellular acidification", Biosens. Bioelectron, 7(4), pp.257~272 (1992)
  14. M. Varshney, "Interdigitated array microelectrode based impedance biosensor coupled with magnetic nanoparticle-antibody conjugates for detection of Escherichia coli O157:H7 in food samples", Biosens. Bioelectron, 22, pp.2408~2414 (2007)
  15. A. Bonanni, "Signal amplification for impedimetric genosensing using gold-streptavidin nanoparticles", Electrochim. Acta, 53, pp.4022~4029 (2008)
  16. A. Ramkumar, "Silica nanoparticle tags for capacitive affinity sensors", Proc. of the 2005 IEEE Engineering in Medicine and Biology, pp.1~4 (2005), Shanghai, China

관련 논문AI추천

이 간행물의 다른 논문 (12건)