u-Health 서비스 지원을 위한 착용형 옥시미터를 이용한 맥파 분석 시스템
Pulse wave analysis system using wrist type oximeter for u-Health service
1
조회
0
다운로드
6
인용
0
참고문헌
키워드
초록
This paper describes a real time reliable monitoring method and analysis system using wrist type oximeter for ubiquitous healthcare service based on IEEE 802.15.4 standard. Photoplethysmograph(PPG) is simple and cost effective technique to measure blood volume change. In order to obtain and monitor physiological body signals continuously, a small size and low power consumption wrist type oximeter is designed for the measurement of oxygen saturation of a patient unobtrusively. The measured data is transferred to a central PC or server computer by using wireless sensor nodes in wireless sensor network for storage and analysis purposes. LabVIEW server program is designed to monitor stress indicator from heart rate variability(HRV) and process the measured PPG to accelerated plethysmograph(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual’s PPG and be used as estimation of vascular elasticity for blood circulation.
Abstract
This paper describes a real time reliable monitoring method and analysis system using wrist type oximeter for ubiquitous healthcare service based on IEEE 802.15.4 standard. Photoplethysmograph(PPG) is simple and cost effective technique to measure blood volume change. In order to obtain and monitor physiological body signals continuously, a small size and low power consumption wrist type oximeter is designed for the measurement of oxygen saturation of a patient unobtrusively. The measured data is transferred to a central PC or server computer by using wireless sensor nodes in wireless sensor network for storage and analysis purposes. LabVIEW server program is designed to monitor stress indicator from heart rate variability(HRV) and process the measured PPG to accelerated plethysmograph(APG) by appling second order derivatives in server PC. These experimental results demonstrate that APG can precisely describe the features of an individual’s PPG and be used as estimation of vascular elasticity for blood circulation.
참고문헌 (14)
- I. Akyildiz, "A survey on sensor networks", IEEE Communications Magazine, 40(8) (2002)
- Y. D. Lee, "A wireless health monitoring system in multi-hop body sensor networks", ~ (2007)
- Y.Mendelson, "Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography", IEEE Transactionson Biomedical Engineering, 35(10), pp.798~805 (1988)
- 허영정, "광용적맥파(PPG)를 이용한 호흡수 측정에 있어서 동잡음을 이용한 정확도 향상", 센서학회지, 17(6), pp.447~453 (2008), 한국센서학회
- K. Takazawa, "Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform", Hypertension, 32, pp.365~370 (1998)
- J. Simek, "Second derivative of the finger arterial pressure waveform: An insight into dynamics of the peripheral arterial pressure pulse", Physiological Research, 54, pp.505~513 (2005)
- Y. Iketani, "Second derivate of photoplethysmogram in children and young people", Jpn Circ J,, 64, pp.110~116 (2000)
- 우종민, "심박동수 변이(Heart Rate Variability) 측정법의 개념과 임상적 활용", 정신신체의학, 12(1), pp.3~14 (2004), 한국정신신체의학회
- 정기삼, "HRV의 개요", 가정의학회지, 25(11), pp.528~532 (2004)
- "Heart rate variability: standards of measurement, physiological interpretation, and clinical use", Circulation, 93, pp.1043~1065 (1996)
- W. Y. Chung, "Design issues and implementation of query-driven healthcare system using wireless sensor Ad-hoc network", 4th International Workshop on Wearable and Implantable Body Sensor Networks, pp.99~104 (2007)
- 정완영, "확장성이 고려된 IEEE-802.15.4 기반의 저전력 범용 센서노드 설계 및 제작", 센서학회지, 16(4), pp.247~253 (2007), 한국센서학회
- J.G.Webster, "Design of pulse oximeters" (1997), Taylor & Francis Group
