This paper describes a multi channel measurement system which can measure the cellular respiration level in a solution containing cells by using a Clark-type sensor with the solution temperature control unit. The Clark-type sensor can measure the cellular respiration level in the solution because it can measure the reduction current depending on the dissolved oxygen level in the solution. This measurement system was maintained the temperature within ± 0.1 oC of the setting temperature value by on/off control method in order to measure the precise cellular respiration level. The measurement system showed that the applied voltage to the working electrode was very stable(−0.8 V± 0.0071 V) by using proportional control method. From the current measurement, the response time and the linearity correlation coefficient were 25 sec and 0.94, respectively, which are very close to the results of the commercial product. Using this system and the fabricated Clarktype sensor, the average ratio of the uncoupled OCR(oxygen consumption rate) to the coupled OCR was 1.35 and this is almost the same as that obtained from a commercial systems.

Abstract

This paper describes a multi channel measurement system which can measure the cellular respiration level in a solution containing cells by using a Clark-type sensor with the solution temperature control unit. The Clark-type sensor can measure the cellular respiration level in the solution because it can measure the reduction current depending on the dissolved oxygen level in the solution. This measurement system was maintained the temperature within ± 0.1 oC of the setting temperature value by on/off control method in order to measure the precise cellular respiration level. The measurement system showed that the applied voltage to the working electrode was very stable(−0.8 V± 0.0071 V) by using proportional control method. From the current measurement, the response time and the linearity correlation coefficient were 25 sec and 0.94, respectively, which are very close to the results of the commercial product. Using this system and the fabricated Clarktype sensor, the average ratio of the uncoupled OCR(oxygen consumption rate) to the coupled OCR was 1.35 and this is almost the same as that obtained from a commercial systems.

참고문헌 (17)

  1. J. Park, "Microfabricated clark-type sensor for measuring dissolved oxygen", IEEE Sensors 2007 Conference, pp.1412~1415 (2007)
  2. H. K. Lee, "Mitochondria-based model for fetal origin of adult disease and insulin resistance", Ann. N. Y. Acad Sci, 1042, pp.1~18 (2005)
  3. B. B. Lowell, "Mitochondrial dysfunction and type 2 diabetes", Science, 307, pp.384~387 (2005)
  4. 이덕동, "화학 센서 기술", 센서학회지, 18(1), pp.1~21 (2009), 한국센서학회
  5. 이선영, "Ta2O5 감지막의 광지시 전위차형 페니실린 센서", 센서학회지, 15(3), pp.192~198 (2006), 한국센서학회
  6. G. W. McLaughlin, "Microfabricated solid-state dissolved oxygen sensor", Sensors and Actuator B, 83, pp.138~148 (2002)
  7. S. Jung, "Analytic PID controller design technique for a third order system", Conference on Decision and Control 35th Proc, pp.2513~2517 (1996)
  8. C. Lee, "PID control for sType I diabetic patients", Theories and Applications of Chem. Eng, 8(2), pp.2513~2517 (2002)
  9. 감기술, "표준백금저항온도계를 이용한 온도측정능력 상호비교", 센서학회지, 18(1), pp.86~94 (2009), 한국센서학회
  10. C. C. Wu, "Fabrication of miniature Clark oxygen sensor integrated with microstructure", Sensors and Actuators B, 110, pp.342~349 (2005)
  11. H. Suzuki, "Micromachined clark oxygen electrode", Sensors and Actuators B, 10, pp.91~98 (1993)
  12. M. Wittkampf, "Silicon thin film sensor for measurement of dissolved oxygen", Sensors & Actuators B, 45, pp.40~45 (1997)
  13. S. Peteu, "A clark type oxidase enzyme based amperometric microbiosensor for sensing glucose, galactose, or choline", Biosensors & Bioelectronics, 11, pp.1059~1071 (1996)
  14. S. Zimmermann, "In-device enzyme immobilization: waferlevel fabrication of an integrated glucose sensor", Sensors and Actuators B, 99, pp.163~173 (2004)
  15. H. Suzuki, "Fabrication of a sensing module using micromachined biosensors", Biosensors & Bioelectronics, 16, pp.725~733 (2001)
  16. 한근식, "데이터 처리 입문", pp.209~212 (2003), 그린 출판사
  17. K. Renner, "Changes of mitochondrial respiration, mitochondrial content and cell size after induction of apoptosis in leukemia cells", Biochemica et Biophysica Acta, 30(1), pp.129~138 (2001)

관련 논문AI추천

이 간행물의 다른 논문 (9건)