Thiolated protein G로 개질된 SPR 센서 칩을 이용한 IgG 검출
Detection of IgG Using Thiolated Protein G Modified SPR Sensor Chip
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
A portable surface plasmon resonance(SPR) based immunosensor using thiolated protein G and protein G was developed for the detection of immunoglobulin G(IgG). The protein G has specific affinity with Fc fragment of IgG and was thiolated by 2-Iminothiolane for introduction of thiol groups. Anti-IgG, bovine serum albumin(BSA), and IgG have been sequently injected after surface modification of gold sensor chip with protein G and thiolated protein G. The output signal was increased with the injection of each protein and the actual signal was measured by subtracting signal of reference channel from signal of sample injected channel. The experimental results showed the higher detection capability of IgG using thiolated protein G compared with protein G. From these results, we can conclude that the current surface modification technique and the portable SPR sensor system can be applied to various immunosensors for diagnosis.
Abstract
A portable surface plasmon resonance(SPR) based immunosensor using thiolated protein G and protein G was developed for the detection of immunoglobulin G(IgG). The protein G has specific affinity with Fc fragment of IgG and was thiolated by 2-Iminothiolane for introduction of thiol groups. Anti-IgG, bovine serum albumin(BSA), and IgG have been sequently injected after surface modification of gold sensor chip with protein G and thiolated protein G. The output signal was increased with the injection of each protein and the actual signal was measured by subtracting signal of reference channel from signal of sample injected channel. The experimental results showed the higher detection capability of IgG using thiolated protein G compared with protein G. From these results, we can conclude that the current surface modification technique and the portable SPR sensor system can be applied to various immunosensors for diagnosis.
참고문헌 (16)
- 성건용, "유비쿼터스건강관리를 위한 바이오센서 기술 동향", 전자통신동향분석, 24(5), pp.38~51 (2009)
- 조재형, "“Ubiquitous Health Care System”을 이용한 미래형 당뇨병 관리에 대한 전망", Diabetes and Metabolism Journal, 30(2), pp.87~95 (2006), 대한당뇨병학회
- 김의락, "면역센서의 원리와 의학적 응용", KSBB Journal, 17(2), pp.121~136 (2002), 한국생물공학회
- K.A.Mark, "Quartz crystal microbalance:A useful tool for studying thin polymer films and complex biomolecular systems at the solution-surface Interface", Biomacromolecules, 4(5), pp.1099~1120 (2003)
- N. Trummer, "Modification of the surface of integrated opticalwave-guide sensors for immunosensor applications", Fresenius J. Anal. Chem, 371(1), pp.21~24 (2001)
- R. Kurrat, "Plasma protein adsorption on titanium:comparative in situ studies using optical waveguide lightmode spectroscopy and ellipsometry", Colloids Surf. B. Biointerfaces, 11(4), pp.187~201 (1998)
- K. Hegnerova, "Surface plasmon resonance biosensors for detection of Alzheimer disease biomarker", Sens. Actuators B Chem, 139(1), pp.69~73 (2009)
- C. Bian, "A field effect transistor(FET)-based immunosensor for detection of HbA1c and Hb", Biomed. Microdevices, 13(2), pp.345~352 (2011)
- M. Salmain, "Infrared optical immunosensor:application to themeasurement of the herbicide atrazine", Anal.Biochem, 373(1), pp.61~70 (2008)
- 윤성식, "Cyclic olefin copolymer(COC) 폴리머 프리즘을 사용한 광섬유 기반 표면 플라즈몬 공명(SPR) 바이오 센서", 센서학회지, 17(5), pp.369~374 (2008), 한국센서학회
- P. Englebienne, "Surface plasmon resonance:principles,methodsand applications in biomedical sciences", Spectroscopy, 17, pp.255~273 (2003)
- K. S. Lee, "Resolution enhancement in surface plasmon resonance sensor based on waveguide coupled mode by combining a bimetallic approach", Sensors, 10(12), pp.11390~11399 (2010), Molecular Diversity Preservation International
- A.M.Bond, "Past,present and future contributions of microelectrodes to analytical studies employing voltammetric detection.A review", Analyst, 119(11) (1994)
- Y. M. Bae, "Study on orientation of immunoglobulin G on protein G layer", Biosens. Bioelectron, 21(1), pp.103~110 (2005)
- M. Suzuki, "Miniature surface plasmon resonanceimmunosensors-rapid and repetitive procedure", Anal. Chim. Acta, 404(2), pp.187~194 (2000)
- 이은규, "자성 미세입자에의 항체 고정화 방법이 면역결합반응에 미치는 영향", Korean Chemical Engineering Research(HWAHAK KONGHAK), 44(1), pp.65~72 (2006), 한국화학공학회