팔뚝형 자동혈압계 평가용 혈압 시뮬레이터 개발

Development of Blood Pressure Simulator for Test of the Arm-type Automatic Blood Pressure Monitor

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류공학일반

초록

Blood pressure is possible to diagnose a disease associated with blood pressure and judgment the current health of patients. Automatic blood pressure monitor capable of measuring a blood pressure easily in hospital and at home have become spread. In this study, we developed the blood pressure simulator (BPS) that can test the arm-type automatic blood pressure monitor that is commonly used in hospital. BPS is to produce a pressure similar to the pressure wave generated in the human blood using a servo disk motor. Then, using the silicon tube, it implements the situations such as human blood vessels, and to output the generated pressure waveform. Simply the BPS's phantom put on the cuff and it is able to simulate blood pressure. So anyone can quickly test the blood pressure monitor within one minute and it is possible to shorten the test time required for the automatic blood pressure monitor. In Performance test, the trends and the standard deviation of the values measured in the BPS is similar to the value of the measured pressure from people with normal blood pressure. Thus, the development BPS showed a possibility of taking into account the actual blood pressure measurement environment simulator.

Abstract

Blood pressure is possible to diagnose a disease associated with blood pressure and judgment the current health of patients. Automatic blood pressure monitor capable of measuring a blood pressure easily in hospital and at home have become spread. In this study, we developed the blood pressure simulator (BPS) that can test the arm-type automatic blood pressure monitor that is commonly used in hospital. BPS is to produce a pressure similar to the pressure wave generated in the human blood using a servo disk motor. Then, using the silicon tube, it implements the situations such as human blood vessels, and to output the generated pressure waveform. Simply the BPS's phantom put on the cuff and it is able to simulate blood pressure. So anyone can quickly test the blood pressure monitor within one minute and it is possible to shorten the test time required for the automatic blood pressure monitor. In Performance test, the trends and the standard deviation of the values measured in the BPS is similar to the value of the measured pressure from people with normal blood pressure. Thus, the development BPS showed a possibility of taking into account the actual blood pressure measurement environment simulator.

참고문헌 (17)

  1. H. Asada, "Towards the development of wearable blood pressure sensor : A photo-plethysmograph approach using conducting polymer actuators", IEEE-EMBS, 27th Annual International Conference of the IEEE, pp.4156~4159 (2005)
  2. 박경남, "승압제를 사용하는 쇼크 환자에서 맥파전달시간을 이용한 비침습적혈압 측정에 대한 비교 연구", 대한중환자의학회지, 24(1), pp.11~16 (2009), 대한중환자의학회
  3. "Electronic medical equipment based on standards by Korean food and drug administration", IEC(International Electrotechnical Commission) 60601-2-30 Particular requirements for the safety, including essential performance of automatic cycling non-invasive blood pressure monitoring equipment, ~
  4. H. Schroder, "Relationship between diet and blood pressure in a representative Mediterranean population", European journal of nutrition, 41(4), pp.161~167 (2002)
  5. Task Force for the management of arterial hypertension of the European Society of Hypertension, "2013 ESH", ESC guidelines for the management of arterial hypertension, 2013, pp.22(4), 193~
  6. The Seventh Report of the Joint National Committee onPrevention, Detection, Evaluation, and Treatment of High Blood Pressure, "U.S. Department of health and human services", U.S. Department of health and human services, ~ (2004)
  7. S. H. Suh, "Modelling of elastic blood vessel under the pulsatile flow", The Korean Society for Vascular Surgery, 15(2) (1999)
  8. 박상갑, "복합운동트레이닝이 50대 대사증후군 남성의 신체조성과 경동맥 및 상완동맥의 내경에 미치는 영향", 한국사회체육학회지, 34(34), pp.1017~1028 (2008), 한국사회체육학회
  9. A. P. Avolio, "Multi-branched model of the human arterial system", Medical and Biological Engineering and Computing, 18(6), pp.709~718 (1980)
  10. D. Legendre, "Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases", Artificial organs, 32(6), pp.461~467 (2008)
  11. 이주연, "혈압파형에 초점을 맞춘 심혈관계 시뮬레이터의 개발", 의공학회지, 34(1), pp.40~45 (2013), 대한의용생체공학회[DOI]
  12. S. Y. Woo, "Development of standard and improvement of reliability in blood pressure measurement", Journal of the Korean Society for Precision Engineering, 24(9), pp.12~16 (2007)
  13. "2013 hypertension treatment guidelines of the Republic of Korea", ~
  14. "BP Pump 2 NIBP Simulator and Tester Operation Manual", ~
  15. 곽관웅, "기계적 한계를 고려한 심혈관 순환계 임피던스 시뮬레이터 설계 및 평가", 한국정밀공학회지, 25(1), pp.151~159 (2008), 한국정밀공학회
  16. S. H. Jung, "Analytical study on the critical design parameters of micro-pressure regulator using property of incompressible fluid", 박사, pp.2012
  17. "Quality Control and Assurance of Blood Pressure Measurement KNHANES5", ~ (2011)

관련 논문AI추천

이 간행물의 다른 논문 (11건)