초록

Objectives: Acceleration plethysmogram (APG) obtained from the second derivative of photoplethysmography (PPG) is used to predict risk factors for atherosclerosis with age. This technique is promising for early screening of atherosclerotic pathologies. However, extraction of the wave indices of APG signals measured from the fingertip is challenging. In this paper, the development of a wave detection algorithm including a preamplifier based on a microcontroller that can detect the a, b, c, and d wave indices is proposed. Methods: The 4th order derivative of a PPG under real measurements of an APG waveform was introduced to clearly separate the components of the waveform, and to improve the rate of successful wave detection. A preamplifier with a Sallen-Key low pass filter and a wave detection algorithm with programmable gain control, mathematical differentials, and a digital IIR notch filter were designed. Results: The frequency response of the digital IIR filter was evaluated, and a pulse train consisting of a specific area in which the wave indices existed was generated. The programmable gain control maintained a constant APG amplitude at the output for varying PPG amplitudes. For 164 subjects, the mean values and standard deviation of the a wave index corresponding to the magnitude of the APG signal were 1,106.45 and ±47.75, respectively. Conclusions: We conclude that the proposed algorithm and preamplifier designed to extract the wave indices of an APG in real-time are useful for evaluating vascular aging in the cardiovascular system in a simple healthcare device.

Abstract

Objectives: Acceleration plethysmogram (APG) obtained from the second derivative of photoplethysmography (PPG) is used to predict risk factors for atherosclerosis with age. This technique is promising for early screening of atherosclerotic pathologies. However, extraction of the wave indices of APG signals measured from the fingertip is challenging. In this paper, the development of a wave detection algorithm including a preamplifier based on a microcontroller that can detect the a, b, c, and d wave indices is proposed. Methods: The 4th order derivative of a PPG under real measurements of an APG waveform was introduced to clearly separate the components of the waveform, and to improve the rate of successful wave detection. A preamplifier with a Sallen-Key low pass filter and a wave detection algorithm with programmable gain control, mathematical differentials, and a digital IIR notch filter were designed. Results: The frequency response of the digital IIR filter was evaluated, and a pulse train consisting of a specific area in which the wave indices existed was generated. The programmable gain control maintained a constant APG amplitude at the output for varying PPG amplitudes. For 164 subjects, the mean values and standard deviation of the a wave index corresponding to the magnitude of the APG signal were 1,106.45 and ±47.75, respectively. Conclusions: We conclude that the proposed algorithm and preamplifier designed to extract the wave indices of an APG in real-time are useful for evaluating vascular aging in the cardiovascular system in a simple healthcare device.

참고문헌 (11)

  1. Nousou N, "Classification of acceleration plethysmogram using selforganizing map", Proceedings of International Symposium on Intelligent Signal Processing and Communications (ISPACS'06), pp.681~684 (2006)
  2. Takazawa K, "Assessment of vasoactive agents and vascular aging by the second derivative of photoplethysmogram waveform", Hypertension, 32(2), pp.365~370 (1998)
  3. Micans P, "Aortic wave velocity : a noninvasive method to measure the stiffness of arteries and the clinical results of supplements that appear to improve arterial stiffness", Curr Aging Sci, 6(1), pp.76~85 (2013)
  4. Blazek R, "Multi-resolution linear model comparison for detection of dicrotic notch and peak in blood volume pulse signals", Anal Biomed Signals Images, 20, pp.378~386 (2010)
  5. Antonelli L, "Dicrotic notch detection using wavelet transform analysis", Proceedings of the 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering Advances: New Opportunities for Biomedical Engineers, pp.1216~1217 (1994)
  6. Elgendi M, "Detection of c, d, and e waves in the acceleration photoplethysmogram", Biomedical Engineering Online, 13, pp.139~158 (2014)
  7. Imanaga I, "Correlation between wave components of the second derivative of plethysmogram and arterial distensibility", Jpn Heart J, 39(6), pp.775~784 (1998)
  8. 홍경순, "Aging Index using Photoplethysmography for a Healthcare Device: Comparison with Brachial-Ankle Pulse Wave Velocity", Healthcare Informatics Research, 21(1), pp.30~34 (2015), 대한의료정보학회[DOI]
  9. Roggan A, "Optical properties of circulating human blood in the wavelength range 400-2500 nm", J Biomed Opt, 4(1), pp.36~46 (1999)
  10. Reisner A, "Utility of the photoplethysmogram in circulatory monitoring", Anesthesiology, 108(5), pp.950~958 (2008)
  11. Elgendi M, "On the analysis of fingertip photoplethysmogram signals", Curr Cardiol Rev, 8(1), pp.14~25 (2012)