X-ray tube 내 열유동 해석에 관한 연구

A study on the analysis of heat flow in X-ray tube

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

As the aging ages, the disease also increases, and the development of AI technology and X-ray equipment used to treat patients' diseases is also progressing a lot. X-ray tube converts only 1% of electron energy into X-ray and 99% into thermal energy. Therefore, when the cooling time of the anode and the X-ray tube are frequently used in large hospitals, the amount of X-ray emission increases due to temperature rise, the image quality deteriorates due to the difference in X-ray dose, and the lifespan of the overheated X-ray tube may be shortened. Therefore, in this study, temperature rise and cooling time of 60kW, 75kW, and 90kW of X-ray tube anode input power were studied. In the X-ray Tube One shot 0.1s, the section where the temperature rises fastest is 0.03s from 0s, and it is judged that the temperature has risen by more than 50%. The section in which the temperature drop changes most rapidly at 20 seconds of cooling time for the X-ray tube is 0.1 seconds to 0.2 seconds, and it is judged that a high temperature drop of about 65% or more has occurred. After 20 seconds of cooling time from 0 seconds to 0.1 seconds of the X-ray tube, the temperature is expected to rise by more than 3.7% from the beginning. In particular, since 90kW can be damaged by thermal shock at high temperatures, it is necessary to increase the surface area of the anode or to require an efficient cooling system.

Abstract

As the aging ages, the disease also increases, and the development of AI technology and X-ray equipment used to treat patients' diseases is also progressing a lot. X-ray tube converts only 1% of electron energy into X-ray and 99% into thermal energy. Therefore, when the cooling time of the anode and the X-ray tube are frequently used in large hospitals, the amount of X-ray emission increases due to temperature rise, the image quality deteriorates due to the difference in X-ray dose, and the lifespan of the overheated X-ray tube may be shortened. Therefore, in this study, temperature rise and cooling time of 60kW, 75kW, and 90kW of X-ray tube anode input power were studied. In the X-ray Tube One shot 0.1s, the section where the temperature rises fastest is 0.03s from 0s, and it is judged that the temperature has risen by more than 50%. The section in which the temperature drop changes most rapidly at 20 seconds of cooling time for the X-ray tube is 0.1 seconds to 0.2 seconds, and it is judged that a high temperature drop of about 65% or more has occurred. After 20 seconds of cooling time from 0 seconds to 0.1 seconds of the X-ray tube, the temperature is expected to rise by more than 3.7% from the beginning. In particular, since 90kW can be damaged by thermal shock at high temperatures, it is necessary to increase the surface area of the anode or to require an efficient cooling system.

참고문헌 (5)

  1. 이석문, "Thermal Characteristics of Rotating Anode X-ray Tube with Emissivity in Aging Process for Digital Radiography", Applied Science and Convergence Technology, 24(5), pp.125~131 (2015), 한국진공학회[DOI]
  2. 이석문, "Compact Anode Design with the Heat Capacity Performance in Rotating Anode X-ray Tube for Digital Radiography", Applied Science and Convergence Technology, 24(5), pp.136~141 (2015), 한국진공학회[DOI]
  3. 위은찬, "유한요소해석을 이용한 백그라인딩 장비의 구조안정성 연구", Design & Manufacturing, 14(4), pp.58~64 (2020), 한국금형공학회[DOI]
  4. 신봉철, "유동해석을 통한 MR fluid jet polishing 시스템의 재료제거 특성 분석", Design & Manufacturing, 13(3), pp.12~18 (2019), 한국금형공학회[DOI]
  5. 이준엽, "텅스텐의 열충격 손상에 대한 초음파 특성 평가", 동력시스템공학회지, 22(4), pp.5~10 (2018), 한국동력기계공학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (9건)