SNR and CNR were evaluated to investigate the effect of reducing the stomach, duodenum,and intestinal gas artifacts through transducer compression and position changes to obtaina good image of the abdominal organs (centered on the pancreas) in abdominal ultrasonographyperformed after gastroscopy, abdominal ultrasound examination after colon cleansing andabdominal ultrasonography performed after simultaneous gastroscopy and colonoscopy. Therewas a difference between SNR and CNR according to the presence or absence of compression, butcompression did not affect the ultrasound sequence and weight. There was a significant differencein the CNR in the position change but the change in the position did not affect the abdominalultrasonography order and the weight group. The results of qualitative evaluation showed that therewere differences in the clarity, internal structure, and visual range of the pancreatic head accordingto the pressure and the change of the position, and the order of abdominal ultrasonography andweight group were affected. In the case of obesity, abdominal ultrasonography should be performedbefore the endoscopy to avoid obstruction of artifacts such as gastric and intestinal gas and intestinalfluid by attenuation due to subcutaneous fat or visceral fat of the abdominal wall. In order to removestomach and intestinal gas that may interfere with abdominal ultrasonography. Therefore, improvethe quality of the images, it is considered that the pressure of the transducer and the change of theposition of the examinee should be performed.

Abstract

SNR and CNR were evaluated to investigate the effect of reducing the stomach, duodenum,and intestinal gas artifacts through transducer compression and position changes to obtaina good image of the abdominal organs (centered on the pancreas) in abdominal ultrasonographyperformed after gastroscopy, abdominal ultrasound examination after colon cleansing andabdominal ultrasonography performed after simultaneous gastroscopy and colonoscopy. Therewas a difference between SNR and CNR according to the presence or absence of compression, butcompression did not affect the ultrasound sequence and weight. There was a significant differencein the CNR in the position change but the change in the position did not affect the abdominalultrasonography order and the weight group. The results of qualitative evaluation showed that therewere differences in the clarity, internal structure, and visual range of the pancreatic head accordingto the pressure and the change of the position, and the order of abdominal ultrasonography andweight group were affected. In the case of obesity, abdominal ultrasonography should be performedbefore the endoscopy to avoid obstruction of artifacts such as gastric and intestinal gas and intestinalfluid by attenuation due to subcutaneous fat or visceral fat of the abdominal wall. In order to removestomach and intestinal gas that may interfere with abdominal ultrasonography. Therefore, improvethe quality of the images, it is considered that the pressure of the transducer and the change of theposition of the examinee should be performed.

참고문헌 (9)

  1. 장용석, "컴퓨터단층촬영 결과를 기준으로 본 건강검진 상복부 초음파 검사의 정확도 평가 및 발견하지 못한 병변에 대한 고찰", 대한영상의학회지, 70(5), pp.363~368 (2014), 대한영상의학회[DOI]
  2. Jung SY, "Korean National Guidelines on Screening and Surveillance for Early Detection of Colorectal Cancers", Korean J. Soc. Gastro. Endo, 24(6), pp.317~320 (2002)
  3. Jung YH., "Service Quality Analysis on Group Patients -Targeting I Examination Center", Major in Health Management ·Health Informatics, pp.2014
  4. Kim MY, "Optimal Scanning of Abdominal Ultrasonography and Trouble Shootings", Clinical and Molecular Hepatology J. Liver Week, pp.506~517 (2018)
  5. Kim PN, "The newest vision of internal medicine", pp.191~199 (2013), Shin won books
  6. 곽종길, "복부초음파 검사 시 탐촉자 압박에 따른 영상 화질 평가", 방사선산업학회지, 12(3), pp.199~207 (2018), (사)한국방사선산업학회[DOI]
  7. Lee MY., "The study on the prevalence Rate and Developmental Factors of the Liver Diseases Diagnosed by Ultrasonography", Department of Radiological science, pp.2007
  8. 이강녕, "췌장 질환의 조기 진단", 대한내과학회지, 83(1), pp.56~61 (2012), 대한내과학회[DOI]
  9. Park SE, "Abdominal Ultrasonography: Procedure and Training", Korean J. Fam. Pract, 4(1), pp.28~37 (2014)

관련 논문AI추천

이 간행물의 다른 논문 (11건)