An Assessment of the Usefulness of Time of Flight in Magnetic Resonance Angiography Covering the Aortic Arch

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Carotid angiography covering the aortic arch includes contrast-enhanced magnetic resonance angiography (CEA), which is applied to a large region and usually employs contrast media. However, the use of contrast media can be dangerous in infants, pregnant women, and patients with chronic renal failure (CRF). Follow-up patients informed of a lesion may also want to avoid constant exposure to contrast media. We aimed to apply time-of-flight (TOF) angiography to a large region and compare its usefulness with that of CEA. Ten patients (mean age, 58 years; range, 45~75 years) who visited our hospital for magnetic resonance angiography (MRA) participated in this study. A 3.0 Tesla Achieva magnetic resonance imaging (MRI) system (Philips, Netherland) and the SENSE NeuroVascular 16-channel coil were employed for both methods. Both methods were applied simultaneously to the same patient. Three TOF stacks were connected to cover the aortic arch through the circle of Willis, and CEA was applied in the same manner. For the quantitative assessment, the acquired images were used to set the regions of interest (ROIs) in the common carotid artery (CCA) bifurcation, internal carotid artery, external carotid artery, middle cerebral artery, and vertebral artery, and to obtain the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) for the soft tissues. Three radiologists and one radiological resident performed the qualitative assessment on a 5-point scale - 1 point, “very bad”; 2 points, “bad”; 3 points, “average”; 4 points, “good”; and 5 points, “very good” - with regard to 4 items: (1) sharpness, (2) distortion, (3) vein contamination, and (4) expression of peripheral vessels. For the quantitative assessment, we estimated the mean SNR and CNR in each of the 5 ROIs. In general, the mean SNR was higher in TOF angiography (166.1, 205.2, 154.39, 172.23, and 161.95) than in CEA (92.05, 95.43, 84.76, 73.69, and 88.3). Both methods had a similar mean CNR: 67.62, 106.71, 55.9, 73.74, and 63.46 for TOF angiography, and 67.82, 71.19, 60.52, 49.45, and 64.07 for CEA. In all ROIs, the mean SNR was statistically significant (p<0.05), whereas the mean CNR was insignificant (p>0.05). The mean values of TOF angiography and CEA for each item in the qualitative assessment were 4.2 and 4.28, respectively for item 1; 2.93 and 4.55, respectively, for item 2; 4.6 and 3.13, respectively, for item 3; and 2.88 and 4.65, respectively, for item 4. Therefore, TOF angiography had a higher mean for item 3, and CEA had a higher mean for items 2 and 4; there was no significant difference between the two methods for item 1. The results for item 1 were statistically insignificant (p>0.05), whereas the results for items 2~4 were statistically significant (p<0.05). Both methods have advantages and disadvantages and they complement each other. However, CEA is usually applied to a large region covering the aortic arch. Time-of-flight angiography may be useful for people such as infants, pregnant women, CRF patients, and followup patients for whom the use of contrast media can be dangerous or unnecessary, depending on the circumstance.

Abstract

Carotid angiography covering the aortic arch includes contrast-enhanced magnetic resonance angiography (CEA), which is applied to a large region and usually employs contrast media. However, the use of contrast media can be dangerous in infants, pregnant women, and patients with chronic renal failure (CRF). Follow-up patients informed of a lesion may also want to avoid constant exposure to contrast media. We aimed to apply time-of-flight (TOF) angiography to a large region and compare its usefulness with that of CEA. Ten patients (mean age, 58 years; range, 45~75 years) who visited our hospital for magnetic resonance angiography (MRA) participated in this study. A 3.0 Tesla Achieva magnetic resonance imaging (MRI) system (Philips, Netherland) and the SENSE NeuroVascular 16-channel coil were employed for both methods. Both methods were applied simultaneously to the same patient. Three TOF stacks were connected to cover the aortic arch through the circle of Willis, and CEA was applied in the same manner. For the quantitative assessment, the acquired images were used to set the regions of interest (ROIs) in the common carotid artery (CCA) bifurcation, internal carotid artery, external carotid artery, middle cerebral artery, and vertebral artery, and to obtain the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) for the soft tissues. Three radiologists and one radiological resident performed the qualitative assessment on a 5-point scale - 1 point, “very bad”; 2 points, “bad”; 3 points, “average”; 4 points, “good”; and 5 points, “very good” - with regard to 4 items: (1) sharpness, (2) distortion, (3) vein contamination, and (4) expression of peripheral vessels. For the quantitative assessment, we estimated the mean SNR and CNR in each of the 5 ROIs. In general, the mean SNR was higher in TOF angiography (166.1, 205.2, 154.39, 172.23, and 161.95) than in CEA (92.05, 95.43, 84.76, 73.69, and 88.3). Both methods had a similar mean CNR: 67.62, 106.71, 55.9, 73.74, and 63.46 for TOF angiography, and 67.82, 71.19, 60.52, 49.45, and 64.07 for CEA. In all ROIs, the mean SNR was statistically significant (p<0.05), whereas the mean CNR was insignificant (p>0.05). The mean values of TOF angiography and CEA for each item in the qualitative assessment were 4.2 and 4.28, respectively for item 1; 2.93 and 4.55, respectively, for item 2; 4.6 and 3.13, respectively, for item 3; and 2.88 and 4.65, respectively, for item 4. Therefore, TOF angiography had a higher mean for item 3, and CEA had a higher mean for items 2 and 4; there was no significant difference between the two methods for item 1. The results for item 1 were statistically insignificant (p>0.05), whereas the results for items 2~4 were statistically significant (p<0.05). Both methods have advantages and disadvantages and they complement each other. However, CEA is usually applied to a large region covering the aortic arch. Time-of-flight angiography may be useful for people such as infants, pregnant women, CRF patients, and followup patients for whom the use of contrast media can be dangerous or unnecessary, depending on the circumstance.

참고문헌 (13)

  1. Anzalone N, "MR angiography of the carotid arteriesand intracranial circulation: advantage of a high relaxivity contrast agent", Neuroradiology, 48(1), pp.9~17 (2006)
  2. Bakker J, "Preoperative evaluation of living renal donors with gadolinium-enhanced magnetic resonance angiography", Transplantation, 67(8), pp.1167~1172 (1999)
  3. 최진하, "뇌동맥 경화증 진단에서 삼차원 비약시간기법을 이용한 자기공명혈관조영술과 조영증강 자기공명혈관촬영술의 비교 연구", 대한영상의학회지, 64(3), pp.203~211 (2011), 대한영상의학회
  4. Hashemi RH, "MRI The Basics" (2010), Williams and Wilkins
  5. 홍민희, "가돌리늄 기반 조영제 주입 후에 발생한 신성 전신 섬유화증 1예", 대한내과학회지, 78(1), pp.127~131 (2010), 대한내과학회
  6. 전상훈, "신부전 환자에서 혈청 BNP 측정의 유용성", 대한내과학회지, 69(2), pp.135~143 (2005), 대한내과학회
  7. Laub GA, "Time-of-flight method of MR angiography", Magn. Reson. Imaging Clin. N. Am, 3(3), pp.391~398 (1995)
  8. Michaely HJ, "High-resolution renal MRA: comparison of image quality and vessel depiction with different parallel imaging acceleration factors", J. Magn. Reson. Imaging, 24(1), pp.95~100 (2006)
  9. Nael K, "Contrast-enhanced MR angiography at 3T in the evaluation of intracranial aneurysms: a comparison with time-of-flight MR angiography", Am. J. Neuroradiol, 27(1), pp.2118~2121 (2006)
  10. Nichols W, "McDonald’s Blood Flow in Arteries" (2011), Hodder Arnold
  11. Parker DL, "Optimized visualization of vessels in contrast enhanced intracranial MR angiography", Magn. Reson. Med, 40(6), pp.873~882 (1998)
  12. Pennell DJ, "Assessment of coronary artery stenosis by magnetic resonance imaging", Heart, 75(2), pp.127~133 (1996)
  13. Sadikin C, "The current role of 1.5T non-contrast 3D time-of-flight magnetic resonance angiography to detect intracranial steno-occlusive disease", J. Formos. Med. Assoc, 106(9), pp.691~699 (2007)

관련 논문AI추천

내경동맥의 협착 및 폐색의 평가에 있어서의 비침습적인 영상의학적 검사방법들의 비교 연구 : CT혈관조영술(CTA), 유체속도강도 자기공명혈관조영술(TOF-MRA), 조영증강 자기공명혈관조영술(CE-MRA)서상현, 이경열, 이준형, 정태섭대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2011 · 제15권 제3호내경동맥 협착의 평가에 있어서 조영증강 자기공명혈관조영과 삼차원 비약시간 자기공명혈관조영의 비교김용범대한뇌졸중학회 · 대한뇌졸중영문학회지2005 · 제7권 제2호Contrast-Enhanced Magnetic Resonance Angiography for Evaluation of the Steno-occlusive Disease of the Supraaortic Arteries: Comparison with Computed Tomography Angiography and Digital Subtraction Angiography김범수, 김영인, 신용삼, 안국진, 이관성, 이광수, 정소령, 제수경대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2009 · 제13권 제2호정상 뇌혈관 영상에서 3D-TOF 기법과 3D-CTA 기법을 이용한 정량, 정성적 비교 평가구은회(사)한국방사선산업학회 · 방사선산업학회지2024 · 제18권 제4호두개내 동맥협착 평가에 있어서 조영증강 자기공명혈관조영과 유체속도강조 자기공명혈관조영의 비교박광열대한뇌졸중학회 · 대한뇌졸중영문학회지2006 · 제8권 제2호Pseudostenosis at the Origin of the Vertebral Artery on Contrast-enhanced MRA: Correlation with Aortic Motion on Dynamic 3D Time-Resolved Contrast-Enhanced MRA김범수, 김선문, 안국진, 이승원, 정소령, 최현석대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2012 · 제16권 제3호

이 간행물의 다른 논문 (15건)