두개내 동맥협착 평가에 있어서 조영증강 자기공명혈관조영과 유체속도강조 자기공명혈관조영의 비교

Comparison between Contrast-Enhanced MR Angiography and 3D Time-of-Flight MR Angiography in Intracranial Artery Stenosis

1

조회

0

다운로드

0

인용

0

참고문헌

주제분류신경과학

초록

Background:Contrast-enhanced magnetic resonance angiography (CE-MRA) seems better than time-of-flight magnetic resonance angiography (TOF-MRA) in the evaluation of extracranial arteries but to have some limitations in the evaluation of intracranial arteries. We found it showed a tendency to overestimate the stenosis. Objectives:With digital subtraction angiography (DSA) as a gold standard, we tried to find out if CE-MRA overestimates the degrees of stenosis of middle cerebral artery (MCA) and basilar artery (BA). Methods:From April 2003 to August 2006, 93 patients, who underwent TOF-MRA, CE-MRA, and DSA within a month, were enrolled. Fourteen MCA and 3 BA images were missing on DSA, so we could analyze 172 MCAs and 90 BAs. The quality of TOF-MRA, CEMRA, and DSA were classified as adequate or inadequate for analysis. The degree of stenosis was measured by comparing the diameter of the vessel at the site of stenosis with the normal diameter of the vessel just distal to the stenosis and stratified as minimal (1-29%), mild (30-49%), moderate (50-69%) and severe (70-99%) stenosis. Results:Among 172 MCAs, 13 MCAs were excluded because the quality of 11 CE-MRA and 2 TOF-MRA images were inadequate for analysis (6.4% vs. 1.2%, p<0.05). We calculated the agreement (κ) in DSA vs. CE-MRA (κ=0.49, p<0.01) and in DSA vs. TOF-MRA (κ=0.65, p<0.01) in measuring the stenosis of MCA. Among 90 BAs, 7 BAs were excluded because the quality of 6 CE-MRA and 1 TOF-MRA images were inadequate (6.7% vs. 1.1%, p<0.05). We calculated the agreement (κ) in DSA vs. CE-MRA (κ=0.24, p<0.01) and in DSA vs. TOF-MRA (κ=0.45, p<0.01). Conclusion:In comparison to TOF-MRA, CE-MRA tends to overestimate the degree of intracranial artery stenosis and it often shows suboptimal quality. (Korean Journal of Stroke 2006;8:197-203)

Abstract

Background:Contrast-enhanced magnetic resonance angiography (CE-MRA) seems better than time-of-flight magnetic resonance angiography (TOF-MRA) in the evaluation of extracranial arteries but to have some limitations in the evaluation of intracranial arteries. We found it showed a tendency to overestimate the stenosis. Objectives:With digital subtraction angiography (DSA) as a gold standard, we tried to find out if CE-MRA overestimates the degrees of stenosis of middle cerebral artery (MCA) and basilar artery (BA). Methods:From April 2003 to August 2006, 93 patients, who underwent TOF-MRA, CE-MRA, and DSA within a month, were enrolled. Fourteen MCA and 3 BA images were missing on DSA, so we could analyze 172 MCAs and 90 BAs. The quality of TOF-MRA, CEMRA, and DSA were classified as adequate or inadequate for analysis. The degree of stenosis was measured by comparing the diameter of the vessel at the site of stenosis with the normal diameter of the vessel just distal to the stenosis and stratified as minimal (1-29%), mild (30-49%), moderate (50-69%) and severe (70-99%) stenosis. Results:Among 172 MCAs, 13 MCAs were excluded because the quality of 11 CE-MRA and 2 TOF-MRA images were inadequate for analysis (6.4% vs. 1.2%, p<0.05). We calculated the agreement (κ) in DSA vs. CE-MRA (κ=0.49, p<0.01) and in DSA vs. TOF-MRA (κ=0.65, p<0.01) in measuring the stenosis of MCA. Among 90 BAs, 7 BAs were excluded because the quality of 6 CE-MRA and 1 TOF-MRA images were inadequate (6.7% vs. 1.1%, p<0.05). We calculated the agreement (κ) in DSA vs. CE-MRA (κ=0.24, p<0.01) and in DSA vs. TOF-MRA (κ=0.45, p<0.01). Conclusion:In comparison to TOF-MRA, CE-MRA tends to overestimate the degree of intracranial artery stenosis and it often shows suboptimal quality. (Korean Journal of Stroke 2006;8:197-203)

관련 논문AI추천

내경동맥 협착의 평가에 있어서 조영증강 자기공명혈관조영과 삼차원 비약시간 자기공명혈관조영의 비교김용범대한뇌졸중학회 · 대한뇌졸중영문학회지2005 · 제7권 제2호내경동맥의 협착 및 폐색의 평가에 있어서의 비침습적인 영상의학적 검사방법들의 비교 연구 : CT혈관조영술(CTA), 유체속도강도 자기공명혈관조영술(TOF-MRA), 조영증강 자기공명혈관조영술(CE-MRA)서상현, 이경열, 이준형, 정태섭대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2011 · 제15권 제3호뇌졸중 환자에서 3 Tesla 자기공명혈관조영술의 유용성윤웅, 강형근, 서정진, 송상국, 신상수, 임효순, 장남규, 정용연, 정태웅, 한제희대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2005 · 제9권 제2호초급성 허혈성 뇌졸중 환자에서 3.0T 유속증강 자기공명 혈관 조영술을 이용한 임상적 유용성 고찰:1.5T 기준참고 프로토콜구은회, 성경정(사)한국방사선산업학회 · 방사선산업학회지2020 · 제14권 제1호디지털 감산 혈관조영술과 자기 공명 혈관조영술에서 중대뇌동맥의 협착 측정을 위한 North American Symptomatic Carotid Endarterectomy Trial 및 Warfarin-Aspirin Symptomatic Intracranial Disease 방법의 비교 평가김상현, 이정훈대한방사선과학회 · Journal of Radiological Science and Technology2019 · 제42권 제5호급성 및 아급성 뇌경색 환자에서 관류 자기공명영상의 임상적 유용성:중소병원의 경험서형심대한뇌졸중학회 · 대한뇌졸중영문학회지2006 · 제8권 제2호

이 간행물의 다른 논문 (11건)