Precision of Lumbar Bone Mineral Density Measurement with and without Leg Elevation
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
bjectives: There are some report that BMD measurement with the legs down shows no significant change on spine BMD accuracy and precision. We also studied to see the impact of leg elevation from DXA in our country. Methods and Materials: Forty-two volunteers were scanned four times at the lumbar spine using Hologic QDR 4500A. Two scans were done with the leg elevated(E scan) by the spine positioning device supplied by manufacture. The other two scans were done with the legs lying flat(F scan) neutrally without femur positioner. Subjects were repositioned between all four scans. The precision error and linear regression ere determined for the BMD obtained in each position. Results: Mean age of the subjects was 52(range; 40~71). BMD was higher in the F scan(mean: 0.922 g/㎠) compared with E scan(0.907g/㎠) except in two volunteers. T-scores at L1-4 were 0.13 higher for F scan. Only two volunteers had different diagnosis using T-scores from normal to osteopenia and vice versa from the two methods. Precisions(%CV) of the Escan were 1.50, 1.52, 1.96, 1.50, and 0.97% for the L1, L2, L3, L4, and L1-4 respectively. Precisions of the F scan were 1.46, 1.88, 1.63, 1.83, and 1.09% for the L1, L2, L3, L4, and L1-4 respectively. Correlation between two scans was high(r=0.99). Conclusion: Diagnostic differences from E and F scan are very small(0.13 T scores). There is no significant statistical difference in spine BMD between with the legs elevated and with the legs flat on the scan table. One step scan with the leg flat with the dual femur positioner can expedite the examination without jeopardizing diagnostic value.
Abstract
bjectives: There are some report that BMD measurement with the legs down shows no significant change on spine BMD accuracy and precision. We also studied to see the impact of leg elevation from DXA in our country. Methods and Materials: Forty-two volunteers were scanned four times at the lumbar spine using Hologic QDR 4500A. Two scans were done with the leg elevated(E scan) by the spine positioning device supplied by manufacture. The other two scans were done with the legs lying flat(F scan) neutrally without femur positioner. Subjects were repositioned between all four scans. The precision error and linear regression ere determined for the BMD obtained in each position. Results: Mean age of the subjects was 52(range; 40~71). BMD was higher in the F scan(mean: 0.922 g/㎠) compared with E scan(0.907g/㎠) except in two volunteers. T-scores at L1-4 were 0.13 higher for F scan. Only two volunteers had different diagnosis using T-scores from normal to osteopenia and vice versa from the two methods. Precisions(%CV) of the Escan were 1.50, 1.52, 1.96, 1.50, and 0.97% for the L1, L2, L3, L4, and L1-4 respectively. Precisions of the F scan were 1.46, 1.88, 1.63, 1.83, and 1.09% for the L1, L2, L3, L4, and L1-4 respectively. Correlation between two scans was high(r=0.99). Conclusion: Diagnostic differences from E and F scan are very small(0.13 T scores). There is no significant statistical difference in spine BMD between with the legs elevated and with the legs flat on the scan table. One step scan with the leg flat with the dual femur positioner can expedite the examination without jeopardizing diagnostic value.
참고문헌 (17)
- Kanis JA, "Guidelines for Diagnosis and Management of Osteoporosis", Osteoporosis International, 7, pp.390~406 (1997)
- Baim S, "Official positions of the International Society for Clinical Densitometry and executive summary of the 2007 ISCD Position Development Conference", Journal of Clinical Densitometry, 11, pp.75~91 (2008)
- Blake GM, "The role of DXA bone density scans in the diagnosis and treatment of osteoporosis", Postgrad Med J, 83, pp.509~517 (2007)
- Simonelli C, "Comparison of spine BMD measurements from DXA with and without elevated legs", J Bone Miner Res, 17, pp.S412~ (2002)
- "J Clin Densitom", 2003, 182~
- Nord RH, "Effect of patient positioning devices on bone density measurement", J Bone Miner Res, 17, pp.S313~ (2002)
- Kanis JA, "Assessment of fracture risk and its application to screening for postmenopausal osteoporosis: synopsis of a WHO report", Osteoporos Int, 4, pp.368~381 (1994), WHO Study Group
- Hans D, "Skeletal sites for osteoporosis diagnosis: the 2005 ISCD Official Positions", J Clin Densitom, 9, pp.15~21 (2006)
- Lewiecki EM, "DXA quality matters", J Clin Densitom, 9, pp.388~392 (2006)
- Roux C, "Bone densitometry and osteoporosis", J Radiol, 79, pp.821~823 (1998)
- White J, "Precision of single versus bilateral hip bone mineral density", J Bone Miner Res, 17, pp.S314~ (2002)
- Moody SB, "Precision of lumbar spine and femur BMD measurements using Hologic and GE Lunar fan-beam bone densitometers", J Bone Miner Res, 17, pp.S413~ (2002)
- Lekamwasam S, "Effect of leg rotation on hip bone mineral density measurements", J Clin Densitom, 6, pp.331~336 (2003)
- Kaech N, "2003 Does femur positioning affect femur bone mineral density measurement", American Society for Bone and Mineral Research (2003)
- Goh JC, "Effect of femoral rotation on bone mineral density measurements with dual energy X-ray absorptiometry", Calcif Tissue Int, 57, pp.340~343
- Cheng XG, "Effects of anteversion on femoral bone mineral density and geometry measured by dual energy X-ray absorptiometry: a cadaver study", Bone, 21, pp.113~117 (1997)
- Shagam JY, "Bone densitometry: an update", Radiol Technol, 74, pp.321~338 (2003)