초음파로 측정한 어깨 통증환자의 극상근건의 두께비교: 자기공명영상과 비교
Comparison of the Thickness of the Supraspinatus Tendon in Patient with Shoulder Pain Measured by Ultrasound: Compared with MRI
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The purpose of this study is to measure the thickness of the supraspinatus tendon using ananatomical reference point when prescribing the same ultrasound and magnetic resonance imaging fora group of patients with shoulder pain who need surgery or surgical procedure for the supraspinatustendon. It was intended to suggest a test method. It was confirmed that there was no significantdifference in the results of evaluating the thickness of the supraspinatus tendon by comparing the meanand standard deviation through the images acquired by the two tests. As a result, it was confirmedthat accurate diagnostic information on the thickness of the supraspinatus tendon was possible onlywith ultrasound examination compared to magnetic resonance imaging, which could obtain objectiveinformation. It is expected that the utility of a single examination using ultrasound will expand.
Abstract
The purpose of this study is to measure the thickness of the supraspinatus tendon using ananatomical reference point when prescribing the same ultrasound and magnetic resonance imaging fora group of patients with shoulder pain who need surgery or surgical procedure for the supraspinatustendon. It was intended to suggest a test method. It was confirmed that there was no significantdifference in the results of evaluating the thickness of the supraspinatus tendon by comparing the meanand standard deviation through the images acquired by the two tests. As a result, it was confirmedthat accurate diagnostic information on the thickness of the supraspinatus tendon was possible onlywith ultrasound examination compared to magnetic resonance imaging, which could obtain objectiveinformation. It is expected that the utility of a single examination using ultrasound will expand.
참고문헌 (23)
- Min Hee Lee, "회전근개 파열의 수술 후 영상", 대한영상의학회지, 82(6), pp.1388~1401 (2021), 대한영상의학회
- Yoon JS, "Office management of shoulder disorder", Clin. Pain, 9(2), pp.68~71 (2010)
- 송지영, "한국형 흉부 MRI 영상 진단 정당성 권고안", 대한영상의학회지, 82(3), pp.562~574 (2021), 대한영상의학회
- Kim JM, "Ultrasonographic anatomy of the elbow", J. Korean Assoc. Pain Med, 6(3), pp.94~100 (2008)
- Chae SB, "Usefulness of ultrasonographic diagnosis for knot impingement syndrom : 3 cases report", J. Korean Orthop. Assoc, 6(2), pp.70~75 (2013)
- 박혜림, "근골격 해부학의 최신 지견 및 자기공명영상 소견", 대한영상의학회지, 81(1), pp.2~20 (2020), 대한영상의학회[DOI]
- 남형석, "흔히 발생하는 어깨통증에 대한 보존적 치료", 대한의사협회지, 57(8), pp.661~666 (2014), 대한의사협회[DOI]
- 김해림, "초음파를 이용한 어깨 통증의 진단", 대한내과학회지, 91(2), pp.153~157 (2016), 대한내과학회[DOI]
- Martin JA, "In vivo measured of shearwave speed as a predictor of thendon elasticity and strength", Ultrasound Med. Biol, 41(10), pp.2722~2730 (2015)
- Leong HT, "Ultrasound measurement on acromio-humeral distance and supraspinatus tendon thickness : Test-retest reliability and correlations with shoulder rotational strengths", J. Sports Sci. Med, 15(4), pp.284~291 (2012)
- 김윤성, "관절주변 질환의 초음파 소견", 대한내과학회지, 89(6), pp.620~631 (2015), 대한내과학회[DOI]
- Naidoo N, "The histological analysis of the glenohumeral"crtical zone"", Int. J. Morphol, 34(3), pp.1051~1057 (2016)
- Lhee SH, "Does magnetic resonance imaging appearance of supraspinatus muscle atrophy change after repairing rotator cufftears?", J. Shoulder Elbow Surg, 26(3), pp.416~423 (2017)
- 지명훈, "정상 성인의 좌심실 벽두께와 내강 크기에 대한 심초음파영상과 전산화단층영상의 비교", 방사선기술과학, 41(6), pp.545~552 (2018), 대한방사선과학회[DOI]
- Ahmad ZY, "Imaging review of subscapularis tendon and rotator interval pathology", Radiol. Res. Pract, pp.4009829~ (2022)
- 박기혁, "50세 이상 고령근로자의 근골격계질환 발생특성 및 원인에 관한 연구", 대한인간공학회지, 28(4), pp.139~145 (2009), 대한인간공학회
- 고광표, "자세에 따른 견관절부 초음파 진단 비교", 대한정형외과학회지, 52(4), pp.336~343 (2017), 대한정형외과학회[DOI]
- Kim JM, "The thickness of normal and repaired rotator-cuffmeasured in MRI", J. Korean Shoulder Elbow. Soc, 10(1), pp.42~49 (2007)
- 조재호, "발목 주변 해부학적 구조에 대한 초음파를 이용한 접근", 해부·생물인류학, 34(4), pp.119~125 (2021), 대한체질인류학회
- 김지희, "고식적 견관절 자기공명영상에 추가적인 사각시상면 영상 이용 시극상건 손상 검출 진단능 차이에 대한 고찰", Investigative Magnetic Resonance Imaging, 18(2), pp.157~166 (2014), 대한자기공명의과학회[DOI]
- 길종원, "자기공명영상(MRI) 검사 시 방사선사의 소음노출", 한국콘텐츠학회 논문지, 16(11), pp.699~706 (2016), 한국콘텐츠학회[DOI]
- Soo-Jung Choi, "견관절의 유착성 관절낭염", 대한영상의학회지, 82(6), pp.1355~1365 (2021), 대한영상의학회
- Park GY, "The usefulness of ultrasonographic evaluation in the musculoskeletal disease", J. Korean Acad. Rehabil. Med, 24(6), pp.1142~1147 (2000)