This study aimed to evaluate the effect of file size in measuring the electronic working length of teeth with open apex. Twenty teeth were prepared to make the open apex models. A bur was used to cut a 2-mm apical end; the point where #10K file’s tip was reflected on the cut root surface was set to the actual root canal length (AL). A divergent open apex was prepared by retrograde apical preparation. The teeth that were covered with a gauze soaked with saline were inserted in a plastic mold, and an electronic apex locator was connected with it. In each tooth, #10, #20, #30, #40, #50, #60, #70, and #80 files were inserted into the root canal, and the electronic working length (EL) was measured at the “Apex” signal. Then, the mean difference (ΔL) between the AL and EL was evaluated for each file size. EL measurements with all file sizes were short of the apical foramen, and there was a significant difference when the file size increased from #10 to #20 and #40 to #50. Within this study’s limitations, the file size showed an impact in measuring the teeth’s EL with open apex. When the size of the apical foramen is 1.14 mm, it is more accurate to use a file of #50 size or larger when measuring the working length with an electronic apex locator.

Abstract

This study aimed to evaluate the effect of file size in measuring the electronic working length of teeth with open apex. Twenty teeth were prepared to make the open apex models. A bur was used to cut a 2-mm apical end; the point where #10K file’s tip was reflected on the cut root surface was set to the actual root canal length (AL). A divergent open apex was prepared by retrograde apical preparation. The teeth that were covered with a gauze soaked with saline were inserted in a plastic mold, and an electronic apex locator was connected with it. In each tooth, #10, #20, #30, #40, #50, #60, #70, and #80 files were inserted into the root canal, and the electronic working length (EL) was measured at the “Apex” signal. Then, the mean difference (ΔL) between the AL and EL was evaluated for each file size. EL measurements with all file sizes were short of the apical foramen, and there was a significant difference when the file size increased from #10 to #20 and #40 to #50. Within this study’s limitations, the file size showed an impact in measuring the teeth’s EL with open apex. When the size of the apical foramen is 1.14 mm, it is more accurate to use a file of #50 size or larger when measuring the working length with an electronic apex locator.

참고문헌 (26)

  1. Nekoofar MH, "The fundamental operating principles of electronic root canal length measurement devices", Int Endod J, 39, pp.595~609 (2006)[DOI]
  2. Suzuki K, "Experimental study on iontophoresis", Jpn J Stomatol, 16, pp.411~429 (1942)
  3. Sunada I, "New method for measuring the length of the root canal", J Dent Res, 41, pp.375~387 (1962)[DOI]
  4. Kobayashi C, "New electronic canal measuring device based on the ratio method", J Endod, 20, pp.111~114 (1994)[DOI]
  5. Jenkins JA, "An in vitro evaluation of the accuracy of the root ZX in the presence of various irrigants", J Endod, 27, pp.209~211 (2001)[DOI]
  6. Goldberg F, "In vitro measurement accuracy of an electronic apex locator in teeth with simulated apical root resorption", J Endod, 28, pp.461~463 (2002)[DOI]
  7. Welk AR, "An in vivo comparison of two frequency-based electronic apex locators", J Endod, 29, pp.497~500 (2003)[DOI]
  8. Pratten DH, "Comparison of radiographic and electronic working lengths", J Endod, 22, pp.173~176 (1996)[DOI]
  9. Shacham M, "Accuracy and stability of electronic apex locator length measurements in root canals with wide apical foramen : an ex vivo study", BDJ Open, 6, pp.22~ (2020)[DOI]
  10. Dunlap CA, "An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals", J Endod, 24, pp.48~50 (1998)[DOI]
  11. Laux M, "Apical inflammatory root resorption : a correlative radiographic and histological assessment", Int Endod J, 33, pp.483~493 (2000)[DOI]
  12. 박신영, "주근단공의 조건에 따른 Root ZX의 정확성 평가", Restorative Dentistry and Endodontics, 37(2), pp.68~73 (2012), 대한치과보존학회[DOI]
  13. Hachmeister DR, "The sealing ability and retention characteristics of mineral trioxide aggregate in a model of apexification", J Endod, 28, pp.386~390 (2002)[DOI]
  14. Siqueira JF Jr, "Microbial causes of endodontic flareups", Int Endod J, 36, pp.453~463 (2003)[DOI]
  15. Wu MK, "Apical terminus location of root canal treatment procedures", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 89, pp.99~103 (2000)[DOI]
  16. Gesi A, "Incidence of periapical lesions and clinical symptoms after pulpectomy--a clinical and radiographic evaluation of 1-versus 2-session treatment", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 101, pp.379~388 (2006)[DOI]
  17. Herrera M, "Influence of apical constriction diameter on Root ZX apex locator precision", J Endod, 33, pp.995~998 (2007)[DOI]
  18. Ingle J, "Endodontic instruments and instrumentation", Dent Clin North Am, 1, pp.805~822 (1957)
  19. Whitworth J, "Paediatric dentistry", pp.172~173 (2001), Oxford University Press
  20. Gilbert B, "Endodontic treatment of the open apex", Quintessence Int Dent Dig, 14, pp.293~299 (1983)
  21. Erdemir A, "The influence of irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece", Int Endod J, 40, pp.391~397 (2007)[DOI]
  22. Ebrahim AK, "Ex vivo evaluation of the ability of four different electronic apex locators to determine the working length in teeth with various foramen diameters", Aust Dent J, 51, pp.258~262 (2006)[DOI]
  23. Herrera M, "Critical diameter of apical foramen and of file size using the Root ZX apex locator : an in vitro study", J Endod, 37, pp.1306~1309 (2011)[DOI]
  24. ElAyouti A, "A tactile method for canal length determination in teeth with open apices", Int Endod J, 42, pp.1090~1095 (2009)[DOI]
  25. Franco V, "The endodontic line : a clinical approach", G Ital Endod, 27, pp.2~12 (2013)[DOI]
  26. Kim E, "An in vivo comparison of working length determination by only root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 105, pp.e79~e83 (2008)[DOI]

관련 논문AI추천

An in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand filesMysore Krishnaswamy Manjunath, Paras Mull Gehlot, Vinutha Manjunath대한치과보존학회 · Restorative Dentistry and Endodontics2016 · 제41권 제1호In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramenCarlos Eduardo da Silveira Bueno, Carlos Eduardo Fontana, Daniel Guimarães Pedro Rocha, Fernanda Garcia Tampelini, Marcelo Santos Coelho, Marcos de Azevêdo Rios, Sergio Luiz Pinheiro대한치과보존학회 · Restorative Dentistry and Endodontics2017 · 제42권 제3호Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators김필종, 김홍기, 조병훈대한치과보존학회 · Restorative Dentistry and Endodontics2015 · 제40권 제2호주근단공의 조건에 따른 Root ZX의 정확성 평가박신영, 이동균, 황호길대한치과보존학회 · Restorative Dentistry and Endodontics2012 · 제37권 제2호2종 전자근관장측정기의 일관성에 관한 in vitro 연구김의성, 노병덕, 이승종, 황규용대한치과보존학회 · Restorative Dentistry and Endodontics2008 · 제33권 제1호Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locatorAyhan Eymirli, Emel Uzunoglu, Emre Nagas, Mehmet Özgür Uyanik, Semra Çalt대한치과보존학회 · Restorative Dentistry and Endodontics2015 · 제40권 제1호

이 간행물의 다른 논문 (5건)