본문 바로가기
KERD
논문KCI 등재

Effect of a metallic ultrasonic scaler tip on titanium surfaces: a preliminary study

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

The present study aims to evaluate the effect of a metallic magnetostrictive ultrasonic scaler tip on titanium surfaces. Eighteen identical disks were investigated, 12 (1-untreated and 3-treated group) for surface roughness and 6 for weight change. The power settings of the conventional insert were fixed as high, medium, and low in the blue zone. Surface topography analysis was conducted via scanning electron microscopy (SEM). Furthermore, surface roughness measurements of treated and untreated surfaces were compared using a profilometer. The profilometer showed different roughness findings depending on the applied power. SEM results showed that the damaged height was more pronounced from low to high power. Additionally, the weight change of the titanium was affected by the power setting. Therefore, the power setting must be carefully selected when using this scaler in clinical practice. Moreover, an in vitro study must be conducted under various clinical conditions in the future.

Abstract

The present study aims to evaluate the effect of a metallic magnetostrictive ultrasonic scaler tip on titanium surfaces. Eighteen identical disks were investigated, 12 (1-untreated and 3-treated group) for surface roughness and 6 for weight change. The power settings of the conventional insert were fixed as high, medium, and low in the blue zone. Surface topography analysis was conducted via scanning electron microscopy (SEM). Furthermore, surface roughness measurements of treated and untreated surfaces were compared using a profilometer. The profilometer showed different roughness findings depending on the applied power. SEM results showed that the damaged height was more pronounced from low to high power. Additionally, the weight change of the titanium was affected by the power setting. Therefore, the power setting must be carefully selected when using this scaler in clinical practice. Moreover, an in vitro study must be conducted under various clinical conditions in the future.

참고문헌 (27)

  1. Esposito M, "Interventions for replacing missing teeth : dental implants in zygomatic bone for the rehabilitation of the severely deficient edentulous maxilla", Cochrane Database Syst Rev, (4), pp.CD004151~ (2005)[DOI]
  2. Esposito M, "Interventions for replacing missing teeth : augmentation procedures of the maxillary sinus", Cochrane Database Syst Rev, 2014, pp.CD008397~ (2014)[DOI]
  3. Costa FO, "Microbiological profile associated with peri-implant diseases in individuals with and without preventive maintenance therapy : a 5-year follow-up", Clin Oral Investig, 23, pp.3161~3171 (2019)[DOI]
  4. Atieh MA, "The frequency of peri-implant diseases : a systematic review and meta-analysis", J Periodontol, 84, pp.1586~1598 (2013)[DOI]
  5. Varghese KG, "Rehabilitation of the severely resorbed maxilla by using quad zygomatic implantsupported prostheses : a systematic review and metaanalysis", J Prosthet Dent, 130, pp.543~552 (2023)[DOI]
  6. Herrera D, "Prevention and treatment of peri-implant diseases-the EFP S3 level clinical practice guideline", J Clin Periodontol, 50(Suppl 26), pp.4~76 (2023)[DOI]
  7. Khan SN, "Anatomical three-dimensional model with peri-implant defect for in vitro assessment of dental implant decontamination", Clin Exp Dent Res, 10, pp.e841~ (2024)[DOI]
  8. Su W, "In vitro research of oral microscope-assisted implant surface decontamination", Hua Xi Kou Qiang Yi Xue Za Zhi, 41, pp.350~355 (2023)[DOI]
  9. Steiger-Ronay V, "Location of unaccessible implant surface areas during debridement in simulated periimplantitis therapy", BMC Oral Health, 17, pp.137~ (2017)[DOI]
  10. Chen A, "A review of bacterial colonization on dental implants with various hygiene instruments", Cureus, 15, pp.e47483~ (2023)[DOI]
  11. Ichioka Y, "Decontamination of biofilmcontaminated implant surfaces : an in vitro evaluation", Clin Oral Implants Res, 34, pp.1058~1072 (2023)[DOI]
  12. Drisko CL, "Position paper : sonic and ultrasonic scalers in periodontics. Research, Science and Therapy Committee of the American Academy of Periodontology", J Periodontol, 71, pp.1792~1801 (2000)[DOI]
  13. Ichioka Y, "Surface decontamination of explanted peri-implantitis-affected implants", J Clin Periodontol, 50, pp.1113~1122 (2023)[DOI]
  14. Busslinger A, "A comparative in vitro study of a magnetostrictive and a piezoelectric ultrasonic scaling instrument", J Clin Periodontol, 28, pp.642~649 (2001)[DOI]
  15. Oliver WC, "An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments", J Mater Res, 7, pp.1564~1583 (1992)[DOI]
  16. Smart GJ, "The assessment of ultrasonic root surface debridement by determination of residual endotoxin levels", J Clin Periodontol, 17, pp.174~178 (1990)[DOI]
  17. Roccuzzo A, "Periimplantitis as the consequence of errors in implant therapy", Periodontol 2000, 92, pp.350~361 (2023)[DOI]
  18. Baehni P, "Effects of ultrasonic and sonic scalers on dental plaque microflora in vitro and in vivo", J Clin Periodontol, 19, pp.455~459 (1992)[DOI]
  19. Hussain RA, "An update on the treatment of periimplantitis", Dent Clin North Am, 65, pp.43~56 (2021)[DOI]
  20. Wang CW, "Nonsurgical treatment of periimplantitis", Implant Dent, 28, pp.155~160 (2019)[DOI]
  21. Yen Nee W, "Effects on the titanium implant surface by different hygiene instrumentations : a narrative review", Cureus, 14, pp.e30884~ (2022)[DOI]
  22. Vandeweghe S, "Long-term retrospective follow-up of turned and moderately rough implants in the edentulous jaw", Clin Oral Implants Res, 27, pp.421~426 (2016)[DOI]
  23. Mengel R, "An in vitro study of the treatment of implant surfaces with different instruments", Int J Oral Maxillofac Implants, 13, pp.91~96 (1998)
  24. Unursaikhan O, "Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments", J Periodontal Implant Sci, 42, pp.88~94 (2012)[DOI]
  25. Park JB, "In vitro analysis of the efficacy of ultrasonic scalers and a toothbrush for removing bacteria from resorbable blast material titanium disks", J Periodontol, 84, pp.1191~1198 (2013)[DOI]
  26. Lea SC, "Displacement amplitude of ultrasonic scaler inserts", J Clin Periodontol, 30, pp.505~510 (2003)[DOI]
  27. Trenter SC, "Effect of loading on the vibration characteristics of thin magnetostrictive ultrasonic scaler inserts", J Periodontol, 74, pp.1308~1315 (2003)[DOI]

관련 논문AI추천

여러가지 치과용 자기변형 초음파 스케일러 팁이 티타늄 표면특성에 미치는 영향김설, 김병옥, 설승환, 양민철, 유상준, 이승규, 정석환한국표면공학회 · 한국표면공학회지2024 · 제57권 제4호Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments김창성, 박정철, 이중석, 정의원, 조규성, 차재국, 최성호, Otgonbayar Unursaikhan대한치주과학회 · Journal of Periodontal & Implant Science2012 · 제42권 제3호A comparison of magnetostrictive and piezoelectric ultrasonic scaling devices: an in vitro studyHojatollah Yousefimanesh, Mahdi Kadkhodazadeh, Maryam Robati, Reza Molla대한치주과학회 · Journal of Periodontal & Implant Science2012 · 제42권 제6호Influence of scaling procedures on the integrity of titanium nitride coated CAD/CAM abutmentsCarsten Fischer, Dirk Duddeck, Emmanouil Spanos, Florian Tebbel, Helmut Storck, Peter Gehrke대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제3호The effect of pretreating resorbable blast media titanium discs with an ultrasonic scaler or toothbrush on the bacterial removal efficiency of brushing고민철, 고영경, 박준범, 장윤지대한치주과학회 · Journal of Periodontal & Implant Science2013 · 제43권 제6호Surface alterations following instrumentation with a nylon or metal brush evaluated with confocal microscopy고영경, 김영성, 박준범대한치주과학회 · Journal of Periodontal & Implant Science2019 · 제49권 제5호

이 간행물의 다른 논문 (4건)