본문 바로가기
KERD
논문KCI 등재

Surface alterations following instrumentation with a nylon or metal brush evaluated with confocal microscopy

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: Surface alterations of titanium discs following instrumentation with either a nylon brush or a metal brush were evaluated. Methods: A total of 27 titanium discs with 3 surface types (9 discs for each type), including machined (M) surfaces, sandblasted and acid-etched (SA) surfaces, and surfaces treated by resorbable blast media (RBM), were used. Three discs were instrumented with a nylon brush, another 3 discs were instrumented with a metal brush, and the remaining 3 discs were used as controls for each surface type. Surface properties including the arithmetic mean value of a linear profile (Ra), maximum height of a linear profile (Rz), skewness of the assessed linear profile (Rsk), arithmetic mean height of a surface (Sa), maximum height of a surface (Sz), developed interfacial area ratio (Sdr), skewness of a surface profile (Ssk), and kurtosis of a surface profile (Sku) were measured using confocal microscopy. Results: Instrumentation with the nylon brush increased the Ra, Sa, and Sdr of the M surfaces. On the SA surfaces, Ra, Sa and Sdr decreased after nylon brush use. Meanwhile, the roughness of the RBM surface was not affected by the nylon brush. The use of the metal brush also increased the Ra, Sa, and Sdr of the M surface; however, the increase in Sdr was not statistically significant (P=0.119). The decreases in the Rz, Sz, Ra, Sa, and Sdr of the SA surfaces were remarkable. On the RBM surfaces, the use of the metal brush did not cause changes in Ra and Sa, whereas Rz, Sz, and Sdr were reduced. Conclusions: Titanium surfaces were altered when instrumented either with a nylon brush or a metal brush. Hence, it is recommended that nylon or metal brushes be used with caution in order to avoid damaging the implant fixture/abutment surface.

Abstract

Purpose: Surface alterations of titanium discs following instrumentation with either a nylon brush or a metal brush were evaluated. Methods: A total of 27 titanium discs with 3 surface types (9 discs for each type), including machined (M) surfaces, sandblasted and acid-etched (SA) surfaces, and surfaces treated by resorbable blast media (RBM), were used. Three discs were instrumented with a nylon brush, another 3 discs were instrumented with a metal brush, and the remaining 3 discs were used as controls for each surface type. Surface properties including the arithmetic mean value of a linear profile (Ra), maximum height of a linear profile (Rz), skewness of the assessed linear profile (Rsk), arithmetic mean height of a surface (Sa), maximum height of a surface (Sz), developed interfacial area ratio (Sdr), skewness of a surface profile (Ssk), and kurtosis of a surface profile (Sku) were measured using confocal microscopy. Results: Instrumentation with the nylon brush increased the Ra, Sa, and Sdr of the M surfaces. On the SA surfaces, Ra, Sa and Sdr decreased after nylon brush use. Meanwhile, the roughness of the RBM surface was not affected by the nylon brush. The use of the metal brush also increased the Ra, Sa, and Sdr of the M surface; however, the increase in Sdr was not statistically significant (P=0.119). The decreases in the Rz, Sz, Ra, Sa, and Sdr of the SA surfaces were remarkable. On the RBM surfaces, the use of the metal brush did not cause changes in Ra and Sa, whereas Rz, Sz, and Sdr were reduced. Conclusions: Titanium surfaces were altered when instrumented either with a nylon brush or a metal brush. Hence, it is recommended that nylon or metal brushes be used with caution in order to avoid damaging the implant fixture/abutment surface.

참고문헌 (33)

  1. Zitzmann NU, "Definition and prevalence of peri-implant diseases", J Clin Periodontol, 35, pp.286~291 (2008)
  2. Mombelli A, "The diagnosis and treatment of peri-implantitis", Periodontol 2000, 17, pp.63~76 (1998)
  3. Quirynen M, "An in vivo study of the influence of the surface roughness of implants on the microbiology of supra- and subgingival plaque", J Dent Res, 72, pp.1304~1309 (1993)
  4. Rimondini L, "The effect of surface roughness on early in vivo plaque colonization on titanium", J Periodontol, 68, pp.556~562 (1997)
  5. Bollen CM, "Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature", Dent Mater, 13, pp.258~269 (1997)
  6. Bollen CM, "The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis", Clin Oral Implants Res, 7, pp.201~211 (1996)
  7. Quirynen M, "The influence of titanium abutment surface roughness on plaque accumulation and gingivitis: short-term observations", Int J Oral Maxillofac Implants, 11, pp.169~178 (1996)
  8. Alhag M, "Re-osseointegration on rough implant surfaces previously coated with bacterial biofilm: an experimental study in the dog", Clin Oral Implants Res, 19, pp.182~187 (2008)
  9. Park JB, "Treatment with various ultrasonic scaler tips affects efficiency of brushing of SLA titanium discs", J Craniofac Surg, 24, pp.e119~e123 (2013)
  10. Park JB, "In vitro analysis of the efficacy of ultrasonic scalers and a toothbrush for removing bacteria from resorbable blast material titanium disks", J Periodontol, 84, pp.1191~1198 (2013)
  11. Park JB, "Effects of ultrasonic scaler tips and toothbrush on titanium disc surfaces evaluated with confocal microscopy", J Craniofac Surg, 23, pp.1552~1558 (2012)
  12. Wohlfahrt JC, "Mechanical debridement of a peri-implant osseous defect with a novel titanium brush and reconstruction with porous titanium granules: a case report with reentry surgery", Clin Adv Periodontics, 2, pp.136~140 (2012)
  13. Schmidt KE, "Clinical and laboratory evaluation of the effects of different treatment modalities on titanium healing caps: a randomized, controlled clinical trial", Clin Oral Investig, 22, pp.2149~2160 (2018)
  14. Bertoldi C, "The maintenance of inserted titanium implants: in-vitro evaluation of exposed surfaces cleaned with three different instruments", Clin Oral Implants Res, 28, pp.57~63 (2017)
  15. Chen CJ, "Effects of surface conditions of titanium dental implants on bacterial adhesion", Photomed Laser Surg, 34, pp.379~388 (2016)
  16. Sahrmann P, "In vitro cleaning potential of three different implant debridement methods", Clin Oral Implants Res, 26, pp.314~319 (2015)
  17. Fox SC, "The effects of scaling a titanium implant surface with metal and plastic instruments: an in vitro study", wJ Periodontol, 61, pp.485~490 (1990)
  18. Homiak AW, "Effect of hygiene instrumentation on titanium abutments: a scanning electron microscopy study", J Prosthet Dent, 67, pp.364~369 (1992)
  19. Rühling A, "Treatment of subgingival implant surfaces with Teflon-coated sonic and ultrasonic scaler tips and various implant curettes. An in vitro study", Clin Oral Implants Res, 5, pp.19~29 (1994)
  20. Meschenmoser A, "Effects of various hygiene procedures on the surface characteristics of titanium abutments", J Periodontol, 67, pp.229~235 (1996)
  21. Schmage P, "Effects of 10 cleaning instruments on four different implant surfaces", Int J Oral Maxillofac Implants, 27, pp.308~317 (2012)
  22. Mengel R, "The treatment of uncoated and titanium nitride-coated abutments with different instruments", Int J Oral Maxillofac Implants, 19, pp.232~238 (2004)
  23. Louropoulou A, "Titanium surface alterations following the use of different mechanical instruments: a systematic review", Clin Oral Implants Res, 23, pp.643~658 (2012)
  24. Evans AR, "Confocal imaging, visualization and 3-D surface measurement of small mammalian teeth", J Microsc, 204, pp.108~118 (2001)
  25. Howell K, "Combined confocal microscopy and stereology: a highly efficient and unbiased approach to quantitative structural measurement in tissues", Exp Physiol, 87, pp.747~756 (2002)
  26. Kwan JY, "Implant maintenance using a modified ultrasonic instrument", J Dent Hyg, 64, pp.422~ (1990)
  27. Rapley JW, "The surface characteristics produced by various oral hygiene instruments and materials on titanium implant abutments", Int J Oral Maxillofac Implants, 5, pp.47~52 (1990)
  28. Rimondini L, "Micro-morphometric assessment of titanium plasma-sprayed coating removal using burs for the treatment of peri-implant disease", Clin Oral Implants Res, 11, pp.129~138 (2000)
  29. Rühling A, "Removal of HA and TPS implant coatings and fibroblast attachment on exposed surfaces", Clin Oral Implants Res, 12, pp.301~308 (2001)
  30. Barbour ME, "The effects of polishing methods on surface morphology, roughness and bacterial colonisation of titanium abutments", J Mater Sci Mater Med, 18, pp.1439~1447 (2007)
  31. Duarte PM, "Bacterial adhesion on smooth and rough titanium surfaces after treatment with different instruments", J Periodontol, 80, pp.1824~1832 (2009)
  32. Schwarz F, "Influence of plaque biofilm removal on reestablishment of the biocompatibility of contaminated titanium surfaces", J Biomed Mater Res A, 77A, pp.437~444 (2006)
  33. Bailey GM, "Implant surface alterations from a nonmetallic ultrasonic tip", J West Soc Periodontol Periodontal Abstr, 46, pp.69~73 (1998)

관련 논문AI추천

Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments김창성, 박정철, 이중석, 정의원, 조규성, 차재국, 최성호, Otgonbayar Unursaikhan대한치주과학회 · Journal of Periodontal & Implant Science2012 · 제42권 제3호Altered bacterial adhesion with changes in roughness of titanium surfaces after implant cleaning김슬기, 박세환, 엄흥식, 이시영, 이재관, 장범석치의학연구원 · Oral Biology Research2016 · 제40권 제1호Implant Surface Changes Observed with Confocal and Electron Microscopy After Probing with Metal and Plastic Periodontal Probes고영경, 박준범, 손주완, 진승호대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2023 · 제27권 제4호The effect of pretreating resorbable blast media titanium discs with an ultrasonic scaler or toothbrush on the bacterial removal efficiency of brushing고민철, 고영경, 박준범, 장윤지대한치주과학회 · Journal of Periodontal & Implant Science2013 · 제43권 제6호Effect of a metallic ultrasonic scaler tip on titanium surfaces: a preliminary studyByung-Ock Kim, Hyun-Min Lee, Min-Cheol Yang, Sang-Joun Yu, Seok-Hwan Jeong, Seung-Hwan Seol, Seung-Kyu Lee치의학연구원 · Oral Biology Research2024 · 제48권 제2호The efficacy of different implant surface decontamination methods using spectrophotometric analysis: an in vitro studyDavide Pietropaoli, Enrico Marchetti, Francesco Tarallo, Leonardo Mancini, Philipp Sahrmann, Roberto Gif대한치주과학회 · Journal of Periodontal & Implant Science2023 · 제53권 제4호

이 간행물의 다른 논문 (6건)