본문 바로가기
KERD
논문KCI 등재

Selection of Unnecessary Urine Culture Specimens Using Sysmex UF-5000 Urine Flow Cytometer

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Background: Urine culture is one of the most frequently requested tests in microbiology. Automated urine analyzers yield much infection-related information. The Sysmex UF-5000 analyzer (Sysmex, Japan) is a new flow cytometry urine analyzer capable of quantifying urinary particles, including bacteria, WBCs, and yeast-like cells (YLCs) and can provide a Gram stainability flag. In this work, we evaluated how many unnecessary urine cultures could be screened out using the UF-5000. Methods: We compared the culture results of 126 urine samples among 453 requested urine cultures (from sources other than the Urology and Nephrology departments) with urinalysis results. Urine cultures were considered positive if bacterial or YLC growth was ≥104 CFUs/mL. Results: We used urinalysis cut-off values of 50/μL and 100/μL for bacteria and YLC, respectively. Forty eight of the 126 (38.1%, or 10.6% of 453 requested) cultures were below these cut-off values and did not contain any culture-positive samples. Conclusion: Bacteria and YLC counts generated using the UF-5000 analyzer could be used to screen out negative cultures and reduce urine culture volume by ∼10% without sacrificing detection of positive cultures. (Ann Clin Microbiol 2018;21:-79)

Abstract

Background: Urine culture is one of the most frequently requested tests in microbiology. Automated urine analyzers yield much infection-related information. The Sysmex UF-5000 analyzer (Sysmex, Japan) is a new flow cytometry urine analyzer capable of quantifying urinary particles, including bacteria, WBCs, and yeast-like cells (YLCs) and can provide a Gram stainability flag. In this work, we evaluated how many unnecessary urine cultures could be screened out using the UF-5000. Methods: We compared the culture results of 126 urine samples among 453 requested urine cultures (from sources other than the Urology and Nephrology departments) with urinalysis results. Urine cultures were considered positive if bacterial or YLC growth was ≥104 CFUs/mL. Results: We used urinalysis cut-off values of 50/μL and 100/μL for bacteria and YLC, respectively. Forty eight of the 126 (38.1%, or 10.6% of 453 requested) cultures were below these cut-off values and did not contain any culture-positive samples. Conclusion: Bacteria and YLC counts generated using the UF-5000 analyzer could be used to screen out negative cultures and reduce urine culture volume by ∼10% without sacrificing detection of positive cultures. (Ann Clin Microbiol 2018;21:-79)

참고문헌 (11)

  1. Foxman B, "The epidemiology of urinary tract infection", Nat Rev Urol, 7, pp.653~660 (2010)
  2. Tambyah PA, "Catheter-associated urinary tract infection is rarely symptomatic: a prospective study of 1,497 catheterized patients", Arch Intern Med, 160, pp.678~682 (2000)
  3. Ruben FL, "Clinical infections in the noninstitutionalized geriatric age group: methods utilized and incidence of infections. The Pittsburgh Good Health Study", Am J Epidemiol, 141, pp.145~157 (1995)
  4. Broeren MA, "Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer", J Clin Microbiol, 49, pp.1025~1029 (2011)
  5. De Rosa R, "Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection", Clin Chim Acta, 411, pp.1137~1142 (2010)
  6. Kim SY, "Evaluation of the Sysmex UF-100 urine cell analyzer as a screening test to reduce the need for urine cultures for community-acquired urinary tract infection", Am J Clin Pathol, 128, pp.922~925 (2007)
  7. Manoni F, "Cutoff values for bacteria and leukocytes for urine flow cytometer Sysmex UF-1000i in urinary tract infections", Diagn Microbiol Infect Dis, 65, pp.103~107 (2009)
  8. Previtali G, "Performance evaluation of the new fully automated urine particle analyser UF-5000 compared to the reference method of the Fuchs-Rosenthal chamber", Clin Chim Acta, 472, pp.123~130 (2017)
  9. 박주원, "자동 요침사분석기 iQ200의 평가", Annals of Laboratory Medicine, 28(4), pp.267~273 (2008), 대한진단검사의학회
  10. Manoni F, "Field evaluation of a second-generation cytometer UF-100 in diagnosis of acute urinary tract infections in adult patients", Clin Microbiol Infect, 8, pp.662~668 (2002)
  11. Sobel JD, "Mandell, Douglas, and Bennett's Principles and Practice of Infectious Diseases", pp.886~913 (2015), Elsevier Saunders

관련 논문AI추천

이 간행물의 다른 논문 (3건)