본문 바로가기
KERD
논문KCI 등재

노멕스 허니콤 구조 직물을 적용한 소방관용 특수방화복 개발 및이의 보호 쾌적 성능평가

Development of Firefighters’ Personal Protective Clothing with Nomex HoneycombFabric and its Protective and Comfort Evaluation

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류생활과학

초록

The present study newly developed a firefighters’ protective jacket and pants using a Nomex honeycomb structured layer (HPC) in cases of being exposed to flashover or flameover. This study evaluated the protective and comfort functions of an HPC compared to the current KFI firefighters’ protective clothing (FPC). The results are as follows. First, thermal protective performance (TPP) of fabric layers was 2.75 times greater for HPC than FPC at 125 kW/m2. Second, the predicted second and third degree burn areas were smaller for HPC than FPC when using a flame manikin. Third, thermal insulation using a thermal manikin was 0.2 clo greater for HPC than FPC. Fourth, there were no marked differences in maximal performance, mobility, and microclimate temperature/humidity between FPC and HPC through human wear trials. The thermal insulation of HPC was higher than that of FPC; however, any negative effect of HPC thermal insulation on the comfort functions for firefighters was not found. In conclusion, the newly-developed HPC provided more protection in reducing burn injuries from 125 kW/m2, while no negative impact on maximal performance, mobility and thermal comfort functions of firefighters, which is appropriate for quick-evasive tactics at the flashover, flameover or back draft fires.

Abstract

The present study newly developed a firefighters’ protective jacket and pants using a Nomex honeycomb structured layer (HPC) in cases of being exposed to flashover or flameover. This study evaluated the protective and comfort functions of an HPC compared to the current KFI firefighters’ protective clothing (FPC). The results are as follows. First, thermal protective performance (TPP) of fabric layers was 2.75 times greater for HPC than FPC at 125 kW/m2. Second, the predicted second and third degree burn areas were smaller for HPC than FPC when using a flame manikin. Third, thermal insulation using a thermal manikin was 0.2 clo greater for HPC than FPC. Fourth, there were no marked differences in maximal performance, mobility, and microclimate temperature/humidity between FPC and HPC through human wear trials. The thermal insulation of HPC was higher than that of FPC; however, any negative effect of HPC thermal insulation on the comfort functions for firefighters was not found. In conclusion, the newly-developed HPC provided more protection in reducing burn injuries from 125 kW/m2, while no negative impact on maximal performance, mobility and thermal comfort functions of firefighters, which is appropriate for quick-evasive tactics at the flashover, flameover or back draft fires.

참고문헌 (18)

  1. Borg, G. A., "Psychophysical bases of perceived exertion", Medicine and Science in Sports and Exercise, 14(5), pp.377~381 (1982)
  2. "Casualties and injuries of firefighters" (2006)[URL]
  3. Choi, J. W., "Clothing and health" (2011), Gyomoon
  4. Drysdale, D., "An introduction to fire dynamics" (2005), John Wiley & Sons
  5. Gorbett, G. E., "The current knowledge & training regarding backdraft, flashover, and other rapid fire progression phenomena", Proceedings of the National Fire Protection Association World Safety Conference (2007)
  6. "ISO 10551 Ergonomics of the thermal environment-Assessment of the influence of the thermal environment using subjective judgement scales", International Organization for Standardization, ~ (1995)
  7. "ISO 13506 Protective clothing against heat and flame-test method for complete garments-prediction of burn injury using an instrumented manikin", International Organization for Standardization, ~ (2017)
  8. "ISO 13506 Textiles-Determination of thickness of textiles and textile products", International Organization for Standardization, ~ (2017)
  9. "ISO 9920 Ergonomics of the thermal environment-Estimation of thermal insulation and water vapour resistance of a clothing ensemble", International Organization for Standardization, ~ (2007)
  10. 김도형, "소방복 내 노멕스 냉각복 착용이 모의 소방동작 동안 소방관의 작업 효율에 미치는 영향", 한국생활환경학회지, 26(1), pp.9~24 (2019), 한국생활환경학회[DOI]
  11. Kim, S. Y., "The relationship between clothing microclimate and cold", heat tolerance, Seoul National University, 2005
  12. 김시연, "소방방화복을 착용했을 때의 소방진압 업무 적합도 평가 프로토콜의 개발", 한국화재소방학회 논문지, 30(1), pp.138~148 (2016), 한국화재소방학회[DOI]
  13. Lee, J. Y., "The impact of firefighter personal protective equipment and treadmill protocol on maximal oxygen uptake", Journal of Occupational and Environmental Hygiene, 10(7), pp.397~407 (2013)[DOI]
  14. NFPA 1971, "Standard of protective ensembles for structural fire fighting and proximity fire fighting" (2013), NFPA
  15. "육각형 건축물에 담긴 수학적 비밀" (2019)[URL]
  16. Rossi, R. M., "Thermal energy transfer through heat protective clothing during a flame engulfment test", Textile Research Journal, 84(13), pp.1451~1460 (2014)[DOI]
  17. "Do you wear your aircrew underwear?. The aircrew equipment integration group at the Royal Air Force Centre of aviation medicine conducted burn injury trials at the British Textiles Technology Group" (2014)[URL]
  18. "Testing standards of firefighters’ protective equipment" (2013)[URL]

관련 논문AI추천

이 간행물의 다른 논문 (13건)