본문 바로가기
KERD
논문KCI 등재

서울시 소방공무원의 방화장갑에 대한 평가 및 사용실태

Evaluation of Firefighting Gloves and the Behavior Regarding their Usage, of Firefighting Officials in Seoul

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류생활과학

초록

This study aimed to investigate the evaluation of firefighting gloves and the behavior regarding their usage, of firefighting officials in Seoul, using a questionnaire. Responses from a total of 270 firefighters who are responsible for putting out fires or undertaking rescue works in Seoul were analyzed. As per the findings, the firefighters considered ease of hand operation and fire/flame protection as the most important performance factors for firefighting gloves, and they were satisfied with the supply status of the gloves. The average number of firefighting gloves currently owned by the firefighters was 2.6 ± 0.8 pairs. Thirty-nine percent of the respondents said that their firefighting gloves lasted, with maintained performance, for more than six months and less than a year, and when asked how they handled the gloves with degraded performance, 46% of them said that they would discard them. Sixty-eight percent of the respondents said that they used the most recently developed and supplied gloves, which they considered as the most satisfying gloves and which they mainly used these days. Respondents were highly satisfied with the fire/flame protection performance of their firefighting gloves, but were less satisfied, however, with the glove fit. These results suggest that there has been a significant improvement in the overall performance level and supply status of the firefighting gloves. Given the current situation, careful considerations with flexible approaches are needed on the current firefighting gloves size system as well as on the personal protective equipment maintenance and management scheme.

Abstract

This study aimed to investigate the evaluation of firefighting gloves and the behavior regarding their usage, of firefighting officials in Seoul, using a questionnaire. Responses from a total of 270 firefighters who are responsible for putting out fires or undertaking rescue works in Seoul were analyzed. As per the findings, the firefighters considered ease of hand operation and fire/flame protection as the most important performance factors for firefighting gloves, and they were satisfied with the supply status of the gloves. The average number of firefighting gloves currently owned by the firefighters was 2.6 ± 0.8 pairs. Thirty-nine percent of the respondents said that their firefighting gloves lasted, with maintained performance, for more than six months and less than a year, and when asked how they handled the gloves with degraded performance, 46% of them said that they would discard them. Sixty-eight percent of the respondents said that they used the most recently developed and supplied gloves, which they considered as the most satisfying gloves and which they mainly used these days. Respondents were highly satisfied with the fire/flame protection performance of their firefighting gloves, but were less satisfied, however, with the glove fit. These results suggest that there has been a significant improvement in the overall performance level and supply status of the firefighting gloves. Given the current situation, careful considerations with flexible approaches are needed on the current firefighting gloves size system as well as on the personal protective equipment maintenance and management scheme.

참고문헌 (35)

  1. Arvinte, C., "Technical requirements and materials used in firefighters gloves manufacturing", IOP Conference Series : Materials Science and Engineering, 572(1), pp.012070~ (2019)
  2. "BS EN 659: 2003+A1: 2008, Protective Gloves for Firefighters", British Standard Institution, ~ (2003)
  3. "BS EN 388: 2016+A1: 2018, Protective gloves against mechanical risks", British Standard Institution, ~ (2016)
  4. Hsiao, H., "Sizing firefighters-Method and implications", Human Factors, 56(5), pp.873~910 (2014)[DOI]
  5. Hsiao, H., "Firefighter hand anthropometry and structural glove sizing-A new perspective", Human Factors, 57(8), pp.1359~1377 (2015)[DOI]
  6. Huck, J., "Protective clothing systems-A technique for evaluating restriction of wearer mobility", Applied ergonomics, 19(3), pp.185~190 (1988)[DOI]
  7. Jin, L., "Effect of thermal barrier on thermal protective performance of firefighter garments", Journal of Fiber Bioengineering & Informatics, 4(3), pp.245~252 (2011)[DOI]
  8. "Why did the firefighter have to access ‘AMAZON’?" (2014)[URL]
  9. Kim, D. H., "Questionnaire on firefighters' burn injuries and personal protective equipment in Korea", Proceedings of the 17th International Conference on Environmental Ergonomics, pp.139~ (2017)
  10. 김도희, "실화재 실험을 통한 소방장갑의 열보호 성능평가", 한국생활환경학회지, 28(2), pp.178~188 (2021), 한국생활환경학회[DOI]
  11. Kim, S. J., "Survey on using and management of firefighting clothing among firefighters", Proceedings of the Korea Institute of Fire Science and Engineering Conference, Fall Conference, pp.102~ (2020)
  12. "Regulation No. 153", 2013
  13. "Regulation No. 168", 2014
  14. "Regulation No. 289", 2019
  15. "Regulation No. 330", 2020
  16. 권채령, "소방공무원의 장갑제작을 위한 손 치수 연구", 한국의류학회지, 43(3), pp.416~426 (2019), 한국의류학회[DOI]
  17. "Firefighting gloves - Finding the right fit. LEXIPOL Retrieved March 5" (2009)[URL]
  18. "Enforcement Decree No. 1175 of the Prime Minister's Decree, 2015. 7. 3, enacted", 2015
  19. A study on the health, safety, welfare and policy directions of fire service officials, "National Emergency Management Agency", National Emergency Management Agency, ~ (2014)
  20. "Enforcement 2013. 5. 27. National Emergency Management Agency Order No. 330, 2013. 5. 27, Partially amended", 2013
  21. "Enforcement 2018. 12. 27. Act No. 15301, 2017. 1. 26, Enacted", 2017
  22. , 2019
  23. . Act No. 17517. Partial Amendment, , 2021
  24. "National Fire Agency Directive Notice No. 196 Attached Table 2", 2021
  25. National Fire Protection Association, "NFPA 1851, Standard on selection, care, and maintenance of protective ensembles for structural fire fighting and proximity fire fighting", National Fire Protection Association, ~ (2000)
  26. National Fire Protection Association, "NFPA 1971, Standard on protective ensembles for structural firefighting and proximity firefighting", National Fire Protection Association, ~ (2018)
  27. "Factual survey on fire officials’ human rights" (2015)[URL]
  28. National Human Rights Commission of Korea, "Statement of recommendation for the promotion of the safety and health rights of firefighting officials", NHRCK, ~ (2016)
  29. Huiju Park, "Assessment of Firefighters’ needs for personal protective equipment", Fashion and Textiles, 1(1), pp.1~13 (2014), 한국의류학회[DOI]
  30. "Full set of firefighters’ personal protective equipment appearing at the National Audit" (2014)[URL]
  31. "Consider fit and thermal protection when purchasing firefighter gloves. fire rescue1" (2018)[URL]
  32. Smith, T. D., "Safety specific transformational leadership, safety motivation and personal protective equipment use among firefighters", Safety Science, 131, pp.104930~ (2020)[DOI]
  33. Song, G., "Thermal protective clothing for firefighters" (2016), Woodhead Publishing
  34. Sun, G., "Radiant protective and transport properties of fabrics used by wildland firefighters", Textile Research Journal, 70(7), pp.567~573 (2000)[DOI]
  35. Watkins, J. L., "Evaluation of grip and dexterity test methods for characterization and improvement to structural firefighting glove design", master, pp.2011

관련 논문AI추천

이 간행물의 다른 논문 (9건)