The present study developed a test protocol for evaluating the mobility of firefighting chemical and flame personalprotective equipment (PPE) for the National 119 Rescue Headquarters in Korea and suggested ergonomic design factors toimprove their mobility and performance. Six types of PPE were employed, including three types for flame protective PPE(5 ~ 6 kg excluding the self-contained breathing apparatus), and three types for chemical and flame protective PPE (8 ~11 kg). These PPEs are used by the 119 Rescue firefighters. Three male firefighters (34.3 ± 1.2 y in age, 175 ± 8 cm inheight, 81 ± 13 kg in body weight) participated in the mobility test and interview. A mobility test protocol consisting of 16components (nine postures and seven motions including a dexterity test) along with a visibility test were developed basedon pre-interviews and literature reviews. The findings indicated that the clothing microclimate humidity on the neck andchest exceeded 85%RH on average for all the six PPE conditions, with the chest area reaching as high as 98%RH. This highhumidity caused fogging inside the visor and impaired visibility. The requirements for improving the PPE design in termsof mobility varied depending on whether it was the separated types or all-in-one types, particularly regarding the hood andgloves design. The findings of this study can be applied to improve the design of Level A_PPE for firefighters. The mobilitytest protocol and visibility test developed in this study can also be applied to other types of Level A impermeable PPE.

Abstract

The present study developed a test protocol for evaluating the mobility of firefighting chemical and flame personalprotective equipment (PPE) for the National 119 Rescue Headquarters in Korea and suggested ergonomic design factors toimprove their mobility and performance. Six types of PPE were employed, including three types for flame protective PPE(5 ~ 6 kg excluding the self-contained breathing apparatus), and three types for chemical and flame protective PPE (8 ~11 kg). These PPEs are used by the 119 Rescue firefighters. Three male firefighters (34.3 ± 1.2 y in age, 175 ± 8 cm inheight, 81 ± 13 kg in body weight) participated in the mobility test and interview. A mobility test protocol consisting of 16components (nine postures and seven motions including a dexterity test) along with a visibility test were developed basedon pre-interviews and literature reviews. The findings indicated that the clothing microclimate humidity on the neck andchest exceeded 85%RH on average for all the six PPE conditions, with the chest area reaching as high as 98%RH. This highhumidity caused fogging inside the visor and impaired visibility. The requirements for improving the PPE design in termsof mobility varied depending on whether it was the separated types or all-in-one types, particularly regarding the hood andgloves design. The findings of this study can be applied to improve the design of Level A_PPE for firefighters. The mobilitytest protocol and visibility test developed in this study can also be applied to other types of Level A impermeable PPE.

참고문헌 (42)

  1. 배규태, "구형과 신형 소방 보호장갑의 착탈 시험 및 동작 기민성 평가를 통한 통합형 착용 시험법", 한국의류학회지, 41(5), pp.950~965 (2017), 한국의류학회
  2. Bakri, I., "Effect of fire fighters’ self-contained breathing apparatus’ weight and its harness design on the physiological and subjective responses", Ergonomics, 55(7), pp.782~791 (2012)[DOI]
  3. "A Review of gaps and limitations in test methods for first responder protective clothing and equipment - A final report presented to National Personal Protection Technology Laboratory" (2005)[URL]
  4. Boorady, L. M., "Exploration of firefighter turnout gear part 1 - Identifying male firefighter user needs", Journal of Textile and Apparel, Technology and Management, 8(1), pp.1~13 (2013)
  5. Chou, C., "Physiological strains of wearing aluminized and non-aluminized firefighters’ protective clothing during exercise in radiant heat", Industrial Health, 49, pp.185~194 (2011)[DOI]
  6. Coca, A., "Ergonomic comparison of a chem", bio prototype firefighter ensemble and a standard ensemble, 2008, pp.104, 351~359
  7. Coca, A., "Effects of fire fighter protective ensembles on mobility and performance", Applied Ergonomics, 41(4), pp.636~641 (2010)[DOI]
  8. "Framework Act on Fire Services", Article 1 Section 1, ~ (2021)
  9. Gagge, A. P., "Mechanisms of heat exchange - Biophysics and physiology", Comprehensive Physiology, pp.45~84 (2010)[DOI]
  10. Guidotti, T. L., "Occupational health concerns of firefighting", Annual Review of Public Health, 13(1), pp.151~171 (1992)
  11. Havenith, G., "A test battery related to ergonomics of protective clothing", Applied Ergonomics, 35(1), pp.3~20 (2004)[DOI]
  12. Huck, J., "Fire fighter turnout clothing - Physiological and subjective evaluation", ASTM International, pp.439~451 (1988)[DOI]
  13. Kim, D. H., "Heat strain while wearing pesticide protective clothing in hot environments-Effects of textile physical properties and ambient humidity", International Journal of Industrial Ergonomics, 93, pp.103388~ (2023)[DOI]
  14. Kim, D. H., "A novel vest with dual functions for firefighters : combined effects of body cooling and cold fluid ingestion on the alleviation of heat strain", Industrial Health, 58, pp.91~106 (2020)[DOI]
  15. 김도희, "농연 및 화염 손상 환경에서 소방복의 가시성 평가", 한국생활환경학회지, 26(3), pp.358~373 (2019), 한국생활환경학회[DOI]
  16. 김다미, "기온 70℃의 복사열 노출 환경에서 건조와 젖은 상태의 소방용 보호장갑 착용 시 쾌적성 평가", 한국생활환경학회지, 24(1), pp.95~106 (2017), 한국생활환경학회[DOI]
  17. 김다미, "국내외 보급형 소방용 보호장갑의 동작성 평가 - 착탈 시험, 기민성 시험, 회전력 시험을 중심으로 -", 한국의류학회지, 40(5), pp.921~935 (2016), 한국의류학회
  18. Kim, S., "Skin sites to predict deep-body temperature while wearing firefighters’ personal protective equipment during periodical changes in air temperature", Ergonomics, 59(4), pp.496~503 (2016)[DOI]
  19. 김시연, "소방방화복을 착용했을 때의 소방진압 업무 적합도 평가 프로토콜의 개발", 한국화재소방학회 논문지, 30(1), pp.138~148 (2016), 한국화재소방학회[DOI]
  20. 김시연, "Influences of partial components in firefighters’ personal protective equipment on subjective perception", Fashion and Textiles, 1(1), pp.1~14 (2014), 한국의류학회[DOI]
  21. Kim, S., "Frequency of firefighters' heat-related illness and its association with removing personal protective equipment and working hours", Industrial Health, 57(3), pp.370~380 (2019)[DOI]
  22. "Korea Fire Institute", Korea Fire Institute, ~ (2020)
  23. "Korea Fire Institute", Korea Fire Institute, ~ (2020)
  24. , 2023
  25. Kuno, Y., "Human Perspiration" (1956), Charles C. Thomas
  26. 권주연, "COVID-19 감염병 대응 의료진용 개인보호복의 동작성 및 생리적 부담 평가를 위해 개발된 모의 작업 프로토콜의 타당도", 한국의류산업학회지, 24(5), pp.655~665 (2022), 한국의류산업학회
  27. 이효현, "화재진압 중 소방관의 돌발 고위험상황 노출 경험과개인보호구 개선요구사항 실태조사", 한국생활환경학회지, 24(5), pp.549~561 (2017), 한국생활환경학회[DOI]
  28. 이효현, "대한민국 해군 기존 하절기 함상복과 개발 하절기 함상복의 동작적합성 및 착용 생리반응 평가", 한국생활환경학회지, 23(6), pp.853~867 (2016), 한국생활환경학회[DOI]
  29. Lee, J. Y., "The European, Japanese, and US protective helmet, gloves, and boots for firefighters: thermoregulatory and psychological evaluations", Ergonomics, 57(8), pp.1213~1221 (2014)[DOI]
  30. 임가영, "COVID-19 감염병 대응 의료진의 개인보호구 개선사항 분석 및 동작 프로토콜 개발 - 동작적합성과 쾌적성을 중심으로 -", 한국지역사회생활과학회지, 32(3), pp.363~379 (2021), 한국지역사회생활과학회
  31. Mays, N., "Assessing quality in qualitative research", BMJ, 320(7226), pp.50~52 (2000)[DOI]
  32. McQuerry, M., "Effect of structural turnout suit fit on female versus male firefighter range of motion", Applied Ergonomics, 82, pp.102974~ (2020)[DOI]
  33. National Fire Agency., "2022 National Fire Agency Statistical Yearbook" (2022), National Fire Agency
  34. , 2022
  35. Huiju Park, "Assessment of Firefighters’ needs for personal protective equipment", Fashion and Textiles, 1(1), pp.1~13 (2014), 한국의류학회[DOI]
  36. Park, H., "Impact of firefighter gear on lower body range of motion", International Journal of Clothing Science and Technology, 27, pp.315~334 (2015)[DOI]
  37. Prezant, D. J., "The impact of protective hoods and their water content on the prevention of head burns in New York City firefighters-Laboratory tests and field results", The Journal of Burn Care & Rehabilitation, 22(2), pp.165~178 (2001)[DOI]
  38. Quinn, T. D., "Comparison of three internationally certified firefighter protective ensembles : physiological responses, mobility, and comfort", International Journal of Industrial Ergonomics, 86(2), pp.103232~ (2021)[DOI]
  39. Son, S. Y., "Comparison of firefighter and non-firefighters and the test methods used regarding the effects of personal protective equipment on individual mobility", Applied Ergonomics, 45, pp.1019~1027 (2014)[DOI]
  40. Tochihara, Y., "A review of test methods for evaluating mobility of firefighters wearing personal protective equipment", Industrial Health, 60, pp.106~120 (2022)[DOI]
  41. Van Wely, E., "Current global standards for chemical protective clothing : how to choose the right protection for the right job", Industrial Health, 55(6), pp.485~499 (2017)[DOI]
  42. Walters, T. J., "Thermoregulation by rhesus monkeys at different absolute humidities", Journal of Comparative Physiology B, 174, pp.481~487 (2004)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (10건)