보철용 지르코니아 어버트먼트의 표면적합도와 전기화학적 거동

Surface Compatibility and Electrochemical Behaviors of Zirconia Abutment for Prosthodontics

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기계공학

초록

The fit between dental implant fixture and zirconia abutment is affected by many variables during the fabrication process by CAD/CAM program and milling working. The purpose of this study was to evaluate the surface compatibility and electrochemical behaviors of zirconia abutment for prosthodontics. Zirconia abutments were prepared and fabricated using zirconia block and milling machine. For stabilization of zirconia abutments, sintering was carried out at 1500oF for 7 hrs. The specimens were cut and polished for gap observation. The gap between dental implant fixture and zirconia abutment was observed using field-emission scanning electron microscopy (FE-SEM). The hardness and corrosion resistance of zirconia abutments were observed with vickers hardness tester and potentiostat. The gap between dental implant fixture and zirconia abutment was 5~12mm for small gap, and 40~60mm for large gap. The hardness of zirconia surface was 1275.5 Hv and showed micro-machined scratch on the surface. The corrosion potentials of zirconia abutment/ fixture was -290 mV and metal abutment/fixture was -280mV, whereas|Epit-Ecorr|of zirconia abutment/ fixture (172mV) was higher than that of metal abutment/fixture (150mV). The corrosion morphology of metal abutment/fixture showed the many pit on the surface in compared with zirconia abutment/fixture.

Abstract

The fit between dental implant fixture and zirconia abutment is affected by many variables during the fabrication process by CAD/CAM program and milling working. The purpose of this study was to evaluate the surface compatibility and electrochemical behaviors of zirconia abutment for prosthodontics. Zirconia abutments were prepared and fabricated using zirconia block and milling machine. For stabilization of zirconia abutments, sintering was carried out at 1500oF for 7 hrs. The specimens were cut and polished for gap observation. The gap between dental implant fixture and zirconia abutment was observed using field-emission scanning electron microscopy (FE-SEM). The hardness and corrosion resistance of zirconia abutments were observed with vickers hardness tester and potentiostat. The gap between dental implant fixture and zirconia abutment was 5~12mm for small gap, and 40~60mm for large gap. The hardness of zirconia surface was 1275.5 Hv and showed micro-machined scratch on the surface. The corrosion potentials of zirconia abutment/ fixture was -290 mV and metal abutment/fixture was -280mV, whereas|Epit-Ecorr|of zirconia abutment/ fixture (172mV) was higher than that of metal abutment/fixture (150mV). The corrosion morphology of metal abutment/fixture showed the many pit on the surface in compared with zirconia abutment/fixture.

참고문헌 (13)

  1. L. C. Breeding, , J. Prosthet. Dent, 68, pp.738~ (1992)
  2. T. Jemt, , J. Dent, 21, pp.203~ (1993)
  3. D. B. Gilboe, , J. Prosthet Dent., 32, pp.651~ (1974)
  4. A. S. McMillan, , J. Prosthet. Dent., 79, pp.410~ (1998)
  5. G. A. Zarb, , J. Prosthet. Dent., 64, pp.185~ (1990)
  6. M. L. Myers, , J. Prosthet. Dent., 26, pp.621~ (1983)
  7. 박근형, "Die Spacer가 도포된 보철용 크라운과 어버트먼트의 계면현상", 한국표면공학회지, 40(4), pp.197~202 (2007), 한국표면공학회
  8. C. Piconi, , Biomaterials, 20, pp.1~25 (1999)
  9. M. Geetha, (2009), Prog. in Mater. Sci.
  10. A. J. Denny, "Principles and Prevention of Corrosion", pp.129~ (1992), Macmillan Publishing Company
  11. Z. Szklarska-Smialowska, "Pitting Corrosion of Metals", pp.69~ (1986), National Association of Corrosion Engineers
  12. 오세정, "틈 내 전위측정을 통한 Alloy 600 및 Alloy 690의 틈부식 거동과 재부동태 특성", 한국표면공학회지, 40(2), pp.82~90 (2007), 한국표면공학회
  13. 김성대, "비대칭 마크네트론 스퍼터링을 이용한 이리듐 산화물 박막의 합성과", 한국표면공학회지, 40(5), pp.203~208 (2007), 한국표면공학회

관련 논문AI추천

이 간행물의 다른 논문 (8건)