Experimentalstudywasperformedtounderstandtherealoperationconditionsofashowcaseworkingusually inaconvenientstoreanddiscountstore.Thepurposeofthisstudywastoshow thepossibilityforpracticaluse ofcold-heatstorage systems being operated for the showcase. To do that, evaporator and condenser temperaturesweremeasuredandthecompressorelectricpowerconsumptionweremeasuredsimultaneously. To usetheicestoragesystem,theicemakingprocesswastypicallyoperatedduringmidnightbeingnotneededthe coolingoftheshowcasethroughthecontinuousrunningofthecondenserunit. Andthen,therefrigerantwas subcooledusingthestoredcold-heatafterbeingdischargedfrom thecondenserduringdaytime. So,thecooling performancewasincreasedwiththesub-coolingofrefrigerantduringdaytime,hencetheactualrunningtimeof thecompressorcouldbeeffectivelydecreased.Throughtheexperiments,thisstudyshowedthatthecompressor electric power consumption during daytime could be transferred to nighttime for applying the refrigerant sub-cooling.So,fortheconvenientstore,themaximum loadtransferratesforeachworkingcoolerandshowcase wereestimatedabout31.1% and19.9% respectively.Andforthediscountstore,themaximum loadtransferrates foreachrefrigerationandfreezingshowcasewereestimatedabout34.1% and49.0% respectively.

Abstract

Experimentalstudywasperformedtounderstandtherealoperationconditionsofashowcaseworkingusually inaconvenientstoreanddiscountstore.Thepurposeofthisstudywastoshow thepossibilityforpracticaluse ofcold-heatstorage systems being operated for the showcase. To do that, evaporator and condenser temperaturesweremeasuredandthecompressorelectricpowerconsumptionweremeasuredsimultaneously. To usetheicestoragesystem,theicemakingprocesswastypicallyoperatedduringmidnightbeingnotneededthe coolingoftheshowcasethroughthecontinuousrunningofthecondenserunit. Andthen,therefrigerantwas subcooledusingthestoredcold-heatafterbeingdischargedfrom thecondenserduringdaytime. So,thecooling performancewasincreasedwiththesub-coolingofrefrigerantduringdaytime,hencetheactualrunningtimeof thecompressorcouldbeeffectivelydecreased.Throughtheexperiments,thisstudyshowedthatthecompressor electric power consumption during daytime could be transferred to nighttime for applying the refrigerant sub-cooling.So,fortheconvenientstore,themaximum loadtransferratesforeachworkingcoolerandshowcase wereestimatedabout31.1% and19.9% respectively.Andforthediscountstore,themaximum loadtransferrates foreachrefrigerationandfreezingshowcasewereestimatedabout34.1% and49.0% respectively.

참고문헌 (3)

  1. Park, S-S,, "Technology of the ice storage system", Magazine of the SAREK, 30(6), pp.6~15 (2001)
  2. Lee, D-W., "Sub-cooling effect using cold storage system", Proceedings of the SAREK, 2007, Summer Annual Conference, pp.1067~1071 (2007)
  3. Shin, Y-H., "Measurement and analysis of showcase field data", Proceedings of the SAREK, 17(5), pp.436~443 (2005)