Abstract The cascade refrigeration cycle system has been used mainly to obtain the ultra-lowtemperature. In this study, the effects of internal and outdoor temperatures at chamber on the heatcapacity of fin-tube heat exchangers were examined. In addition, refrigerant line patterns as well asrefrigerant type for cascade cycle were optimized. The results in this study show that the refrigerant linepatterns have greater effect on the sensible capacity than the total capacity. Also, the condenser heatrelease rate for R717-R744 cycle varies the ratio of 46 % with outdoor temperature by comparing withthat of 24% for R134a-R410a cycle.

Abstract

Abstract The cascade refrigeration cycle system has been used mainly to obtain the ultra-lowtemperature. In this study, the effects of internal and outdoor temperatures at chamber on the heatcapacity of fin-tube heat exchangers were examined. In addition, refrigerant line patterns as well asrefrigerant type for cascade cycle were optimized. The results in this study show that the refrigerant linepatterns have greater effect on the sensible capacity than the total capacity. Also, the condenser heatrelease rate for R717-R744 cycle varies the ratio of 46 % with outdoor temperature by comparing withthat of 24% for R134a-R410a cycle.

참고문헌 (13)

  1. Sawalha, S., "Using CO2 in supermarket refrigeration", ASHRAE J., 47(8), pp.26~30 (2005)
  2. Wilson, I., "Carbon dioxide for use as a refrigerant. In: Refrigeration Science and Technology", Proceedings, IIR-IRHACE Conference, Innovative Equipment and Systems for Comfort and Food Preservation, pp.305~311 (2006), The University of Auckland
  3. Park, S. N., "Performance of autocascade refrigeration system using carbon dioxide and R134a", Korea Jou. of Air-Conditioning and Refrigeration Engineering, 11(6), pp.880~890 (1999)
  4. 조홍현, "팽창기를 적용한 이산화탄소 냉방시스템의 성능특성에 관한 해석적 연구", 설비공학 논문집, 19(9), pp.630~639 (2007), 대한설비공학회
  5. 이종석, "증발압력 병렬제어 냉동시스템의 성능해석", 대한기계학회논문집 B, 32(8), pp.567~573 (2008), 대한기계학회
  6. Bivens D. B., "HCFC-22 alternative for air conditioners and heat pumps", ASHRAE Tran, 100(2), pp.566~572 (1994)
  7. 노건상, "대체 프레온계 냉매를 이용하는 2단압축 1단팽창 냉동시스템의 성능예측", 한국기계기술학회지, 14(3), pp.5~10 (2012), 한국기계기술학회[DOI]
  8. 노건상, "친환경 자연냉매를 이용하는 2단압축 2단팽창 냉동시스템의 성능예측", 한국기계기술학회지, 15(3), pp.345~350 (2013), 한국기계기술학회
  9. Lee, T. S., "Thermodynamic analysis of optimal condensing temperature of cascade condenser in CO2", NH3 cascade refrigeration systems, 2006, pp.29(7), 1100~1108
  10. Bhattacharyya, S., "Optimization of a CO2–C3H8 cascade system for refrigeration and heating", Int. J. Refrigeration, 28(8), pp.1284~1292 (2005)
  11. Bansal, P. K., "Cascade systems : past, present, and future", ASHRAE Trans, 113(1), pp.245~252 (2007)
  12. Rees, B., "Performance testing and comparison of liquid overfeed and cascade CO2 systems with R410A primary", International congress of refrigeration, 22 (2007)
  13. "EVAP-COND 3.0", ~

관련 논문AI추천

이 간행물의 다른 논문 (12건)