Kalina 사이클의 효율 향상 방안 및 성능 비교

Improvement of Efficiency of Kalina Cycle and Performance Comparison

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기타공학

초록

In this paper, EP-Kalina cycle applying liquid-vapor ejector and motive pump is newly proposed. In this EP-Kalina cycle, the liquid-vapor ejector is used to increase pressure difference between inlet and outlet of the turbine. Also the motive pump enhances the performance of liquid-vapor ejector, resulting in increase of system efficiency of OTEC cycles. The comparison cycles in this study are basic, Kalina, EKalina and EP-Kalina ones. The pump work, net power, APRe, APRc, TPP and system efficiency of each cycle are compared. In case of net power, EP-Kalina cycle is lowest among the cycles due to the application of the motive pump. But, the net power difference of cycles seems to be minor since the pump work of cycles is merely about 1kW, compared to turbine gross power of 20kW. The system efficiency of EP-Kalina cycle shows 3.22%, relatively 44% higher than that of basic OTEC cycle. Therefore, the system efficiency is increased by applying the liquid-vapor ejector and the motive pump. Additional performance analysis is necessary to optimize the proposed EP-Kalina cycle.

Abstract

In this paper, EP-Kalina cycle applying liquid-vapor ejector and motive pump is newly proposed. In this EP-Kalina cycle, the liquid-vapor ejector is used to increase pressure difference between inlet and outlet of the turbine. Also the motive pump enhances the performance of liquid-vapor ejector, resulting in increase of system efficiency of OTEC cycles. The comparison cycles in this study are basic, Kalina, EKalina and EP-Kalina ones. The pump work, net power, APRe, APRc, TPP and system efficiency of each cycle are compared. In case of net power, EP-Kalina cycle is lowest among the cycles due to the application of the motive pump. But, the net power difference of cycles seems to be minor since the pump work of cycles is merely about 1kW, compared to turbine gross power of 20kW. The system efficiency of EP-Kalina cycle shows 3.22%, relatively 44% higher than that of basic OTEC cycle. Therefore, the system efficiency is increased by applying the liquid-vapor ejector and the motive pump. Additional performance analysis is necessary to optimize the proposed EP-Kalina cycle.

참고문헌 (9)

  1. 윤정인, "다양한 작동유체를 이용한 20 kW급 해양온도차 발전 사이클 성능 분석", 한국마린엔지니어링학회지, 37(8), pp.836~842 (2013), 한국마린엔지니어링학회[DOI]
  2. 고상혁, "원자력 및 신재생에너지 발전비율에 따른 전력단가의 변화", 에너지공학, 15(1), pp.14~22 (2006), 한국에너지학회
  3. L. Syamsuddin, "OTEC Potential in the Indonesian Seas", Energy Procedia, 65, pp.215~222 (2015)
  4. J. I. Yoon, "Performance characteristics of a high-efficiency R717 OTEC power cycle", Applied Thermal Engineering, 72(2), pp.304~308 (2014)
  5. J. I. Yoon, "Performance anclysis of OTEC power cycle with a liquid-vapor ejector using R32", R152a, 2014, pp.15(3), 1~10
  6. H. Uehara, "Performance analysis of OTEC system using a cycle with absorption and extraction processes", Trans. Jpn. Soc. Mech. Eng. (Part B), 64, pp.384~389 (1998)
  7. J. He, "Performance research on modified KCS(Kalina cycle system) 11 without throttle valve", Energy, 64(1), pp.389~397 (2014)
  8. X. Li, "A Kalina cycle with ejector", Energy, 54(1), pp.212~219 (2013)
  9. "Aspen HYSYS, version 8.6" (2014), Aspen Technology Inc