Mock-up실험에 의한 바닥복사 냉방시스템의 온도특성에 관한 연구

A Study on the Temperature Characteristics of the Floor Cooling System of Mock-up Experimentent

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류기타공학

초록

The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16℃. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16℃ is the most proper. In addition, it confirmed that the feed water temperature of 18℃ is effective because the temperature can lower the temperature of a room to 13.55℃, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9℃ on the average, which satisfies the range of 3.0℃ in the standard of ISO.

Abstract

The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16℃. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16℃ is the most proper. In addition, it confirmed that the feed water temperature of 18℃ is effective because the temperature can lower the temperature of a room to 13.55℃, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9℃ on the average, which satisfies the range of 3.0℃ in the standard of ISO.

참고문헌 (12)

  1. 유호천, "건축환경계획" (2006), 태림문화사
  2. 유호천, "건축설비계획" (2005), 태림문화사
  3. 임재한, "주거건물에서 제습시스템이 통합된 바닥복사냉방의 운영방안 평가", 대한건축학회논문집 계획계, 23(10), pp.213~222 (2007), 대한건축학회
  4. 김난행, "건식이중바닥온돌시스템 개발을 위한 실험적 연구", 한국주거학회논문집, 17(3), pp.1~8 (2006), 한국주거학회
  5. 이승복, "바닥복사냉·난방시스템의 유형별 에너지성능 평가", 대한건축학회논문집 계획계, 21(3), pp.133~140 (2005), 대한건축학회
  6. 조영흠, "공동주택 현장 실험을 통한 바닥복사냉방의 성능평가", 대한건축학회논문집 계획계, 20(11), pp.319~326 (2004), 대한건축학회
  7. 조영흠, "공동주택에서 바닥복사냉방의 적정 운영방안에 관한 연구", 설비공학 논문집, 16(6), pp.574~583 (2004), 대한설비공학회
  8. 이승언, "환경 및 시간경과에 따른 건축용 단열재의 열전도율 변화에 관한 실험적 연구", 대한건축학회논문집 계획계, 19(12) (2003), 대한건축학회
  9. 이상엽, "제습기능이 통합된 바닥복사 냉방시스템의 적용 가능성에 관한 실험적 연구", 설비공학 논문집, 14(2), pp.7~ (2002), 대한설비공학회
  10. 특허청, "출원번호. 2006-0034425 인조목재의 제조방법", ~
  11. K, Nagano, "Experiments on thermal environmental design of ceiling radiant cooling for supine human subjects", Building and Environments, 39, pp.487~495 (2004)
  12. J. Miriel, "Radiant ceiling panel heating-cooling system; experimental and simulated study of the performances, thermal comfort and energy consumptions", Applied Thermal Engineering, 22, pp.1861~1875 (2002)

관련 논문AI추천

이 간행물의 다른 논문 (11건)