본문 바로가기
KERD
논문KCI 등재

태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가

Assessment of Daylight Environment on Light Pipe System Under Different Solar Position

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류기타공학

초록

The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)×6m(D)×4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

Abstract

The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)×6m(D)×4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

참고문헌 (9)

  1. 윤현주, "건축과 자연채광 시스템", pp.56~59 (2008), 삼성건설기술 친환경에너지팀
  2. L SHAO, "A Study of Performance of Light Pipes Under Cloudy and Sunny Condition in the UK", The 4th European C oference on Energy-Efficient Lighting (1997), Denmark
  3. L. Shao, "measurement and modelling of light pipe for energy efficient lighting", CIBSE National Lighting Conference Paper (1998)
  4. G. OAKLEY, "Daylight Performance of Lightpipes", Solar Energy, 69(2), pp.89~98 (2000), Solar Energy
  5. M. paronicini, "Monitoring of a light-pipe system", Sola r Energy, 81, pp.1180~1186 (2007), Sola r Energy
  6. 김정태, "광파이프 시 스템의 채광성능 평가", 대한건축학회 논문집, 17(4), pp.119~124 (2001)
  7. 신혜미, 박훈, 김정태, "수직형 라이트파이프의 채광성능에 관한 예비평가", 한국생태환경건축학회 논문집, 8(1), pp.53~60 (2008), 한국생태환경건축학회
  8. Laouadi,A., "Design Insights on Tubular Skylights", Lighting, 25(1), pp.38~41 (2005), Lighting
  9. KSA 한국표준협회, "KS핸드북 2005 조명"

관련 논문AI추천

이 간행물의 다른 논문 (11건)