A set of candela distribution curves(CDCs) were generated for a fiber optic dish daylighting system by Photopia under clear sky conditions at different solar altitudes. The candela distribution curves were then exported to Radiance for photometric analysis of a windowless lecture room. Observations were made on the Radiance rendered illuminance images, which provided photo realistic scenes varying with solar altitudes. If no tracking error were assumed, the daylight collection efficiency of the system remained at a constant value of 68.4% during its operation. Higher the solar altitude angle, greater in photometric quantities were observed, which are represented by candela(cd) and total lumens(lm). In all cases considered, however, the angle of light distribution remained fixed reflecting the solar tracking feature of the system. The illuminance uniformity on the workplane lingered around 0.12, which is quite low. This is quite a contrast to its average value of 0.68 of the 2.7m2 area directly below the terminal device (diffuser) of the system. The maximum illuminance of 1,340lux was obtained at a solar altitude of 80 degrees.
Abstract
A set of candela distribution curves(CDCs) were generated for a fiber optic dish daylighting system by Photopia under clear sky conditions at different solar altitudes. The candela distribution curves were then exported to Radiance for photometric analysis of a windowless lecture room. Observations were made on the Radiance rendered illuminance images, which provided photo realistic scenes varying with solar altitudes. If no tracking error were assumed, the daylight collection efficiency of the system remained at a constant value of 68.4% during its operation. Higher the solar altitude angle, greater in photometric quantities were observed, which are represented by candela(cd) and total lumens(lm). In all cases considered, however, the angle of light distribution remained fixed reflecting the solar tracking feature of the system. The illuminance uniformity on the workplane lingered around 0.12, which is quite low. This is quite a contrast to its average value of 0.68 of the 2.7m2 area directly below the terminal device (diffuser) of the system. The maximum illuminance of 1,340lux was obtained at a solar altitude of 80 degrees.
참고문헌 (12)
- Korea Energy Economics Institute, "Yearbook of Energy Statistics", ISSN 1226-606X, ~ (2011)
- Hong, G.P, "the introduction of domestic buildings total amount of energy consumption", ~ (2011)
- Study on the Residential Energy Consumption by Use and Retrospective supplements, "Lee, S.G", Research Project Report of the Korea Energy Economics Institute, ~ (2010)
- Lee, H.S, "The effect of Daylighting on Treatment and Life space", Journal of the Korean Solar Energy Society, 5(3), pp.3~8 (2006)
- 몰드변압기 권선부의 열전달 특성 해석, "조명.전기설비학회논문지", 2002, 47~54, pp.한국조명.전기설비학회
- Yang, H.I., "Validating RADIANCE Program as Design and Evaluation Tools for the Luminous Environment", Journal of Architectural Institute of Korea, 20(1), pp.485~488 (2000)
- 한현주, "Design, Fabrication and Performance Analysis of Fibre Optic Concentrators for Daylighting", 한국태양에너지학회 논문집, 27(4), pp.129~136 (2007), 한국태양에너지학회
- Kim, Y.S., "A Study on a Comparison of the Computer Simulated Data and Measured Data of Photometric Data", KIIEE Annual Spric Conference (2006)
- Park, B.C, "Analyzing Daylight Distribution and Evaluating Discomfort Glare of Roller Shades and Venetian Blind Using the RADIANCE Software", Journal of Architectural Institute of Korea, 27(1), pp.993~996 (2007)
- William B, "Stine and michael Geyer, Power from the sun, Chapter.8", pp.3~5
- "The Light Co"[URL]
- David L. DiLaura, "IES handbook 10th edition", pp.281~283 (2011), IESNA