초록

Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.

Abstract

Use of daylight in underground space interacts with physiological need for human beings and provides relief from feeling secluded. Light pipe system can deliver natural light into the space where it is needed and can be used as primary or a secondary light source with benefits of energy, productivity and health. To use light pipe system effectively under various conditions, it is important to investigate the effectiveness of light pipe system with reliable monitoring protocol. This paper presents the results of light pipe system performance used in underground parking lot under different sky conditions. Comparisons were made between the illuminance standards of underground parking lot and the monitored data. The results indicated that adequate illuminance level was shown until 4.5m distance from the light pipe under clear sky condition. However, additional lighting device showed be used under overcast sky to meet the proper illuminance level.

참고문헌 (10)

  1. 공효주, "천공상태에 따른 수직형 광파이프 시스템의 채광성능 평가", 한국생태환경건축학회 논문집, 8(3), pp.101~106 (2008), 한국생태환경건축학회
  2. 신주영, "지하주차장에 적용된 광파이프 시스템의 채광성능 평가에 관한 예비실험", 한국생태환경건축학회 하계학 술발표대회논문집, 16, pp.45~48 (2009)
  3. 신화영, "태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가", 한국태양에너지학회 논문집, 28(6), pp.78~86 (2008), 한국태양에너지학회
  4. 정유근, "공동주택 지하주차장의 자연채광 실태 및 채광성능 평가", 한국생태환경건축학회 논문집, 2(2), pp.39~44 (2002)
  5. 황민구, "공동주택 지하주차 장의 주광 실태 및 천창 개구부 형태에 따 른 채광 성능에 관한 연구", 대한건축학회 추계학술발표대회논문집, 19(2), pp.823~828 (1999)
  6. CarterD J, "Develop mentin tubular daylight guidance systems", Building Research and Information, 32(3), pp.220~234 (2007)
  7. JenkinsD, "A design tool for predicting the performance of light pipe", Energy and Buildings, 37(5), pp.485~492 (2005)
  8. JenkinsD, "Modelling light pipe performances-an aturaldaylighting solution", Building and Environment, 38(7), pp.965~972 (2005)
  9. ParonciniM, "Monitoringo alight-pipe system", Solar Energy, 81(9), pp.1180~1186 (2007)