초록

Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As results, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

Abstract

Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As results, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

참고문헌 (10)

  1. MIT, "The Future of Geothermal Energy" (2006), Massachusetts Institute of Technology
  2. Hadley, D.L, "Federal Technology Alert: Ground-source heat pumps applied to federal facilities―2nd Ed., DOE", EE-0245 (PNNL-13534), 2001
  3. TRNSYS, "A Transient Simulation Program 15, Solar Engineering Lab" (2000), University of Wisconsin Madison
  4. "KS C 9306 Standard, Air-Conditioner", ~ (2007)
  5. 손병후, "지열원 열펌프 시스템의 냉난방 성능 평가", 설비공학 논문집, 17(1), pp.71~81 (2005), 대한설비공학회
  6. 김환용, "냉·난방 부하계산을 위한 전국 17개 도시의 표준기상데이터 및 TAC 맵 작성", 대한건축학회논문집 계획계, 23(9), pp.197~204 (2007), 대한건축학회
  7. Kim S.M., "A Study of the Actual Analysis of Using Hot Water Heating in Apartment Housing with District Heating System", Proceedings of the SAREK Summer Annual Meeting, pp.892~898 (2007)
  8. Wilbert F. Stoecker, "Industrial Refrigeration Handbook" (1998), McGraw-Hill
  9. AHRI, "Standard for Performance Rating of Variable Refrigerant Flow (VRF) Multi-Split Air-Conditioning and Heat Pump Equipment", ~ (2009)

관련 논문AI추천

이 간행물의 다른 논문 (36건)