This paper deals with the effectiveness of a fiber optic solar lighting system that uses a Fresnel lens mounted on a two-axis solar tracker. A series of comparative analyses were made concerning its performance as compared to fluorescent lighting by using a simulation model based on ECOTECT and RADIANCE as well as referring to actual data. ECOTECT was used to model the test room (space) while RADIANCE was used for its indoor lighting conditions (environment). It was found that the average indoor light levels of fluorescent lighting fully satisfy the KS standard (KS A 3011, general office, class [G]: 300-400-600 lux) whereas those of the solar lighting with light diffusers depends on the occlusion factor of roller shades installed on the south window.

Abstract

This paper deals with the effectiveness of a fiber optic solar lighting system that uses a Fresnel lens mounted on a two-axis solar tracker. A series of comparative analyses were made concerning its performance as compared to fluorescent lighting by using a simulation model based on ECOTECT and RADIANCE as well as referring to actual data. ECOTECT was used to model the test room (space) while RADIANCE was used for its indoor lighting conditions (environment). It was found that the average indoor light levels of fluorescent lighting fully satisfy the KS standard (KS A 3011, general office, class [G]: 300-400-600 lux) whereas those of the solar lighting with light diffusers depends on the occlusion factor of roller shades installed on the south window.

참고문헌 (12)

  1. 이충식, "다중 파라볼릭 반사경 방식을 이용한 추적식 집광시스템 개발", 한국태양에너지학회 논문집, 33(2), pp.56~63 (2013), 한국태양에너지학회
  2. 송규동, "자연채광 시스템의 성능 평가를 위한 실내 조도 예측 및 조명제어 컴퓨터 모델 개발", 대한건축학회논문집 계획계, 19(3), pp.211~218 (2003), 대한건축학회
  3. Kim, Y. M., "Study on the Preformance Enhancement of Low-temperature Solar Application: Daylighting and Adsorption Desalination System", Master, pp.2011
  4. Vu, N. H., "Cost-effective Optical Fiber Daylighting System Using Modified Compound Parabolic Concentrators", Solar Energy, 136, pp.145~152 (2016)
  5. Oh, S. J., "Development of an AVR MCU-based Solar Tracker", Journal of Energy Engineering, 20(4), pp.353~357 (2011)
  6. Park, Y. C., "Sun Tracking System for Active Daylighting System", The Society Of Air-Conditioning And refrigerating Engineers Of Korea, 11, pp.47~58 (2000)
  7. Ko, D. H., "Assessment and Analysis of Green Building Performances using Autodesk ECOTECT Analysis 2010", Architectural Institute of Korea, 54(7), pp.56~60 (2010)
  8. 최우람, "ECOTECT 시뮬레이션을 활용한 학교건축의 창호계획에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -", KIEAE Journal, 13(6), pp.77~82 (2013), 한국생태환경건축학회[DOI]
  9. Jeong, H. J., "A Comparative Study on the Economic Feasibility of Fluorescent Lighting and Fiber-optic Daylighting Via LCC Analysis", Energy & Climate Change, 11(2), pp.160~169 (2016)
  10. Cho, K. H., "A Study on the Comparison of Energy Performance in Passive House by Energy Simulation (e-QUEST, ECOTECT Analysis)", Architectural Institute of Korea, 30(1), pp.435~436 (2010)
  11. Daylight in buildings, Energy Conservation in Buildings & Community Systems & Solar Heating and Cooling Programmes, "Johnsen, K.", ~ (2010)
  12. "KS A 3011 Recommended Levels of Illumination", Korean Agency for Technology and Standards, ~ (2013)

관련 논문AI추천

이 간행물의 다른 논문 (4건)