본문 바로가기
KERD
논문KCI 등재

초고층 공동주택의 주방·욕실 배기 풍속을 풍력발전에 활용하는 방안

A Study on the Wind Power Generation Using Vertical Exhaust Air Duct of the High-Rise Apartments.

1

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류기타공학

초록

The purpose of this study was to promote the utilization of wind velocity of kitchen and bathroom exhaust ducts for wind power generation in high-rise apartments. The research content can be summarized as follows:1) Nine high-rise apartments were examined for the installation of kitchen and bathroom exhaust ducts located in the pipe shaft (PS) section. After selecting simulation candidates, a simulation was performed with the STAR-CCM+ Ver 5.06 program. 2) Of nine high-rise apartments, seven had kitchen and bathroom exhaust ducts, whose cross section was in the range of 0.16㎡∼0.4㎡. The area ratio between the exhaust ducts and PS section (cross section of exhaust duct / area of PS section x 100) was on average 3.2%. 3) The simulation results were analyzed. As a result, the smaller cross section kitchen and bathroom exhaust ducts had, the more advantages there were for increasing exhaust wind velocity. If an out air inlet duct is installed to the old kitchen and bathroom exhaust ducts, it will increase exhaust wind velocity by 3.01∼3.98㎧ and contribute to the proper wind velocity level (3.0㎧). 4) When the simultaneous usage rate between the kitchen and bathroom exhaust fan increased from 20% to 60%, exhaust wind velocity increased. The “entire households” condition for exhaust fan operation provided more even exhaust wind velocity than the “some households” condition. 5) Exhaust wind velocity increased in the order of amplified (T-3), induced (T-2) and vertical (T-1) top of kitchen and bathroom exhaust ducts. Of them, the amplified type (T-3) was under the least influence of external wind velocity and thus the most proper for kitchen and bathroom exhaust duct tops.

Abstract

The purpose of this study was to promote the utilization of wind velocity of kitchen and bathroom exhaust ducts for wind power generation in high-rise apartments. The research content can be summarized as follows:1) Nine high-rise apartments were examined for the installation of kitchen and bathroom exhaust ducts located in the pipe shaft (PS) section. After selecting simulation candidates, a simulation was performed with the STAR-CCM+ Ver 5.06 program. 2) Of nine high-rise apartments, seven had kitchen and bathroom exhaust ducts, whose cross section was in the range of 0.16㎡∼0.4㎡. The area ratio between the exhaust ducts and PS section (cross section of exhaust duct / area of PS section x 100) was on average 3.2%. 3) The simulation results were analyzed. As a result, the smaller cross section kitchen and bathroom exhaust ducts had, the more advantages there were for increasing exhaust wind velocity. If an out air inlet duct is installed to the old kitchen and bathroom exhaust ducts, it will increase exhaust wind velocity by 3.01∼3.98㎧ and contribute to the proper wind velocity level (3.0㎧). 4) When the simultaneous usage rate between the kitchen and bathroom exhaust fan increased from 20% to 60%, exhaust wind velocity increased. The “entire households” condition for exhaust fan operation provided more even exhaust wind velocity than the “some households” condition. 5) Exhaust wind velocity increased in the order of amplified (T-3), induced (T-2) and vertical (T-1) top of kitchen and bathroom exhaust ducts. Of them, the amplified type (T-3) was under the least influence of external wind velocity and thus the most proper for kitchen and bathroom exhaust duct tops.

참고문헌 (9)

  1. 조강표, "도시 건축물군 내의 통풍에 관한 연구", 대한건축학회논문집 계획계, 27(03), pp.21~28 (2011), 대한건축학회
  2. Yoon J.O, "Simulations of Wind Environments in the Citis by Computational Fluid Dynamic", Journal of AIK, 27(1), pp.213~220 (2011)
  3. Kim Y.S, "An building load anaysis of ultra high-rise building under the effect of vertical microclimate change", Proceedings of The SAREK, pp.407~412 (2011)
  4. Jun, H. D., "A Study on the Application of Wind Power System in Super High-rise Building", pp.2010
  5. 김주수, "하절기 아파트 단지의 열환경 실측과 CFD를 이용한 해석방법 검증에 관한 연구", 대한건축학회논문집 계획계, 26(05), pp.335~342 (2010), 대한건축학회
  6. Jun, H. D, "A Study on the Application of Wind Power System in Super High-rise Building", pp.2010
  7. Jung-han Park, "A Study on Thermal Phenomena and Stack Effect of Nude Elevator Shaft of High Rise Building that used CFD", SAREK, Summer Annual Conference, pp.1059~1064 (2008)
  8. Jung-han Park, "A Study on Thermal Phenomena and Stack Effect of Nude Elevator Shaft of High Rise Building that used CFD", SAREK, Summer Annual Conference, pp.1059~1064 (2008)
  9. Jo J, H, "A Study on the stack effect in high-rise building", Proceedings of the AIK ‘00 Annual Conference, 30, pp.769~772 (2000)