Thisstudyconductedexperimentstomeasureaircurrentsinanexperimentalbuildingaccordingtoexternal conditions,typesofinductionducts,andtypesofinternalsocketsbyapplyinganexternalinductionductcomprised ofinducingopeningsandlinesandinductionunitstothekitchenandbathroom ventsattherooftopofasuper high-riseapartmentbuildinginordertohelptoimprovetheventingperformance.Thestudyalsoproposedthe optimizationoftheexternalinduction-stylekitchenandbathroom ventscapableofwindpowergeneration. (1)Asforaircurrentdistributionaccordingtoventvelocitychanges,itincreasedtheventingperformanceof thekitchenandbathroom by1.0㎧ atventvelocityof2.0㎧ orhigherandallowedforwindpowergeneration. (2)Asforaircurrentdistributionaccordingtoexternalvelocitychanges,itincreasedtheventingperformance ofthekitchenandbathroom by1.2㎧ atexternalvelocityof2.0㎧ orhigherandallowedforwindpower generation.(3)Asforaircurrentdistributionaccordingtowinddirectionchanges(0∼180°),itwasfavorable forhigherventvelocitywhentheanglebetweentheexternalinductionductdirectionandprevailingwind directionwaswithin±30°.(4)Asforaircurrentdistributionaccordingtoinductionducttype,the[M1]type combiningtheinducingopeningsandlineswiththeinductionunitsrecordedthehighestimprovementeffects inthekitchenandbathroom ventingperformancebyincreasingventvelocityby46%.(5)Asforaircurrent distributionaccordingtothechangingtypesofinternalsocketswherethemainductsofthekitchenand bathroom areconnectedtotheexternalinductionducts,theventuritubetype[Sv]increasedventvelocity by66% basedonthesmoothestexternalinflow.

Abstract

Thisstudyconductedexperimentstomeasureaircurrentsinanexperimentalbuildingaccordingtoexternal conditions,typesofinductionducts,andtypesofinternalsocketsbyapplyinganexternalinductionductcomprised ofinducingopeningsandlinesandinductionunitstothekitchenandbathroom ventsattherooftopofasuper high-riseapartmentbuildinginordertohelptoimprovetheventingperformance.Thestudyalsoproposedthe optimizationoftheexternalinduction-stylekitchenandbathroom ventscapableofwindpowergeneration. (1)Asforaircurrentdistributionaccordingtoventvelocitychanges,itincreasedtheventingperformanceof thekitchenandbathroom by1.0㎧ atventvelocityof2.0㎧ orhigherandallowedforwindpowergeneration. (2)Asforaircurrentdistributionaccordingtoexternalvelocitychanges,itincreasedtheventingperformance ofthekitchenandbathroom by1.2㎧ atexternalvelocityof2.0㎧ orhigherandallowedforwindpower generation.(3)Asforaircurrentdistributionaccordingtowinddirectionchanges(0∼180°),itwasfavorable forhigherventvelocitywhentheanglebetweentheexternalinductionductdirectionandprevailingwind directionwaswithin±30°.(4)Asforaircurrentdistributionaccordingtoinductionducttype,the[M1]type combiningtheinducingopeningsandlineswiththeinductionunitsrecordedthehighestimprovementeffects inthekitchenandbathroom ventingperformancebyincreasingventvelocityby46%.(5)Asforaircurrent distributionaccordingtothechangingtypesofinternalsocketswherethemainductsofthekitchenand bathroom areconnectedtotheexternalinductionducts,theventuritubetype[Sv]increasedventvelocity by66% basedonthesmoothestexternalinflow.

참고문헌 (8)

  1. 이용호, "초고층 공동주택의 주방·욕실 배기 풍속을 풍력발전에 활용하는 방안", 한국태양에너지학회 논문집, 32(3), pp.2~10 (2012), 한국태양에너지학회[DOI]
  2. Kim, S. Y, "Hwang, Airflow measuring analysis the rooftop kitchen and bathroom exhaust duct of residential building", SAREK, Sumer Annual Conference, pp.798~801 (2012)
  3. Park, J. H, "A Experimental Study on the Application of Small Wind Power System Combined Ventilator in Super High-rise Apartment", SAREK, Sumer Annual Conference, pp.725~728 (2012)
  4. 신재렬, "건물 풍력발전을 위한 집풍장치 성능 연구", 한국유체기계학회 논문집, 15(4), pp.42~49 (2012), 한국유체기계학회[DOI]
  5. Nam, B. H., "Wind-induced Variation of Velocity for Tall-building with Openings with the CFD Simulations", Journal of WEIK, 15, pp.209~214 (2012)
  6. Kim, H. G., "The Korea Wind Resource Map and Its Application System", Journal of WEIK, 15, pp.11~15 (2012)
  7. 노지웅, "풍력환기에 의한 아트리움의 열환경 개선에 관한 연구", 한국태양에너지학회 논문집, 32(1), pp.40~47 (2012), 한국태양에너지학회
  8. Jo, H. J., "A Study of Wind energy Assessment according to number and geometry of inlet to top floor of Tall Building", Journal of AIK, 31(2), pp.107~108 (2011)

관련 논문AI추천

이 간행물의 다른 논문 (18건)