초록

In this study, the effect of flush-out temperature on indoor pollutant reduction was studied in a thermal environment chamber, whose design resembles that of a residential building. The results of this study and those of previous studies were compared. The measurement was carried out at 11°C and 16°C following a 6-day flush-out at. Consequently, the pollutants decreased by compared to 56% ~ 78% in previous studies. The flush-out had a reduction effect on the pollutants even at low temperatures. When compared with field measurement results, the effect of the pollutants reduced by flush-out temperature was different; however, it was confirmed that the flush-out has some effect of reducing pollutants even at low temperatures. By comparing the current results with those of field and chamber experiments conducted in previous studies with a t-test, the p-value was 0.05 or higher, indicating that the number of temperature-induced ventilations in the entire dataset was not a significant factor in the pollutant reduction effect. Therefore, based on the t-test analysis results of pollutant reduction effect by temperature, it was confirmed that the higher the temperature, the greater the pollutant reduction effect, 13% to 80%. The difference in the reduction effect by temperature varied for each pollutant.

Abstract

In this study, the effect of flush-out temperature on indoor pollutant reduction was studied in a thermal environment chamber, whose design resembles that of a residential building. The results of this study and those of previous studies were compared. The measurement was carried out at 11°C and 16°C following a 6-day flush-out at. Consequently, the pollutants decreased by compared to 56% ~ 78% in previous studies. The flush-out had a reduction effect on the pollutants even at low temperatures. When compared with field measurement results, the effect of the pollutants reduced by flush-out temperature was different; however, it was confirmed that the flush-out has some effect of reducing pollutants even at low temperatures. By comparing the current results with those of field and chamber experiments conducted in previous studies with a t-test, the p-value was 0.05 or higher, indicating that the number of temperature-induced ventilations in the entire dataset was not a significant factor in the pollutant reduction effect. Therefore, based on the t-test analysis results of pollutant reduction effect by temperature, it was confirmed that the higher the temperature, the greater the pollutant reduction effect, 13% to 80%. The difference in the reduction effect by temperature varied for each pollutant.

참고문헌 (6)

  1. Fang, L., "Impact of Temperature and Humidity on Chemical and Sensory Emissions from Building Materials", Indoor Air, 9, pp.193~201 (1999)
  2. Ando, M., "Indoor Air and Human Health-sick House Syndrome and Multiple Chemical Sensitivity", Kokuritsu Iyakuhin Shokuhin Eisei Kenkyujo Hokoku=Bulletin of National Institute of Health Sciences, 120, pp.6~38 (2020)
  3. 정수연, "HB마크 건축자재 마감에 따른 공동주택에서의 폼알데하이드와 VOCs 장기 농도 변화에 관한 연구", 대한건축학회논문집, 23(7), pp.277~286 (2007), 대한건축학회
  4. 유복희, "신축 공동주택에서의 온도 및 습도 변화에 따른 VOC 및 포름알데히드 방산 관계성 규명", 대한건축학회논문집, 26(05), pp.383~391 (2010), 대한건축학회
  5. Lee, K. Y., "Optimizing Flush-out Process for Removing Indoor Pollutants in Residential Buildings", Master, pp.2016
  6. Park, S. I., "Removal of Indoor Air Pollutants in Newly Built Residential Buildings using by Flush-out Method", Master, pp.2019