플러쉬아웃 공기 온도에 따른 신축공동주택의 실내 오염물질 저감효과에 관한 연구
Effects of Flush-out Air Temperature on Reducing Indoor Air Pollutants in Newly Built Residential Buildings
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this study, the effect of flush-out temperature on indoor pollutant reduction was studied in a thermal environment chamber, whose design resembles that of a residential building. The results of this study and those of previous studies were compared. The measurement was carried out at 11°C and 16°C following a 6-day flush-out at. Consequently, the pollutants decreased by compared to 56% ~ 78% in previous studies. The flush-out had a reduction effect on the pollutants even at low temperatures. When compared with field measurement results, the effect of the pollutants reduced by flush-out temperature was different; however, it was confirmed that the flush-out has some effect of reducing pollutants even at low temperatures. By comparing the current results with those of field and chamber experiments conducted in previous studies with a t-test, the p-value was 0.05 or higher, indicating that the number of temperature-induced ventilations in the entire dataset was not a significant factor in the pollutant reduction effect. Therefore, based on the t-test analysis results of pollutant reduction effect by temperature, it was confirmed that the higher the temperature, the greater the pollutant reduction effect, 13% to 80%. The difference in the reduction effect by temperature varied for each pollutant.
Abstract
In this study, the effect of flush-out temperature on indoor pollutant reduction was studied in a thermal environment chamber, whose design resembles that of a residential building. The results of this study and those of previous studies were compared. The measurement was carried out at 11°C and 16°C following a 6-day flush-out at. Consequently, the pollutants decreased by compared to 56% ~ 78% in previous studies. The flush-out had a reduction effect on the pollutants even at low temperatures. When compared with field measurement results, the effect of the pollutants reduced by flush-out temperature was different; however, it was confirmed that the flush-out has some effect of reducing pollutants even at low temperatures. By comparing the current results with those of field and chamber experiments conducted in previous studies with a t-test, the p-value was 0.05 or higher, indicating that the number of temperature-induced ventilations in the entire dataset was not a significant factor in the pollutant reduction effect. Therefore, based on the t-test analysis results of pollutant reduction effect by temperature, it was confirmed that the higher the temperature, the greater the pollutant reduction effect, 13% to 80%. The difference in the reduction effect by temperature varied for each pollutant.
참고문헌 (6)
- Fang, L., "Impact of Temperature and Humidity on Chemical and Sensory Emissions from Building Materials", Indoor Air, 9, pp.193~201 (1999)
- Ando, M., "Indoor Air and Human Health-sick House Syndrome and Multiple Chemical Sensitivity", Kokuritsu Iyakuhin Shokuhin Eisei Kenkyujo Hokoku=Bulletin of National Institute of Health Sciences, 120, pp.6~38 (2020)
- 정수연, "HB마크 건축자재 마감에 따른 공동주택에서의 폼알데하이드와 VOCs 장기 농도 변화에 관한 연구", 대한건축학회논문집, 23(7), pp.277~286 (2007), 대한건축학회
- 유복희, "신축 공동주택에서의 온도 및 습도 변화에 따른 VOC 및 포름알데히드 방산 관계성 규명", 대한건축학회논문집, 26(05), pp.383~391 (2010), 대한건축학회
- Lee, K. Y., "Optimizing Flush-out Process for Removing Indoor Pollutants in Residential Buildings", Master, pp.2016
- Park, S. I., "Removal of Indoor Air Pollutants in Newly Built Residential Buildings using by Flush-out Method", Master, pp.2019