본문 바로가기
KERD
논문KCI 등재

민감시설의 건물 특성에 따른 실내공기질 분석

Analysis of Indoor Air Quality in vulnerable facilities according to building characteristics

1

조회

0

다운로드

7

인용

0

참고문헌

키워드

주제분류건축공학

초록

Purpose: With the increasing of public-use facilities, there has been a growing concern over Indoor Air Quality(IAQ) of public-use facilities. Because the facilities are easy to be exposed to indoor air pollutants, they needs to be periodically managed the IAQ. Methods: In this study, indoor air pollutant concentrations of 24 vulnerable facilities were measured and compared. The measurements were conducted for pollutants which are defined in ‘IAQ Control In Public-Use Facilities, etc. Act’. We took two measurements, the first was carried out in summer and the second was proceeded in winter. We analyzed the values according to the type of facilities and pollutants. Results: There was a difference in pollutant concentrations by the season and in occurrence characteristics by the measurement spot. Therefore, we need to manage pollutant concentrations by characteristics of occurrence. Implications: Based on the comparative analysis of pollutant concentrations, we suggested cause and improvement strategies for IAQ management of Vulnerable facilities.

Abstract

Purpose: With the increasing of public-use facilities, there has been a growing concern over Indoor Air Quality(IAQ) of public-use facilities. Because the facilities are easy to be exposed to indoor air pollutants, they needs to be periodically managed the IAQ. Methods: In this study, indoor air pollutant concentrations of 24 vulnerable facilities were measured and compared. The measurements were conducted for pollutants which are defined in ‘IAQ Control In Public-Use Facilities, etc. Act’. We took two measurements, the first was carried out in summer and the second was proceeded in winter. We analyzed the values according to the type of facilities and pollutants. Results: There was a difference in pollutant concentrations by the season and in occurrence characteristics by the measurement spot. Therefore, we need to manage pollutant concentrations by characteristics of occurrence. Implications: Based on the comparative analysis of pollutant concentrations, we suggested cause and improvement strategies for IAQ management of Vulnerable facilities.

참고문헌 (9)

  1. Jang Sung-Ki, "Effects of Indoor Air Pollutants on Human Health", Air Cleaning Technology, 19(1), pp.1~9 (2006)
  2. 김선숙, "국내외 실내공기질 관련 인증제도 비교 분석", 한국건축친환경설비학회 논문집, 6(3), pp.191~196 (2012), 한국건축친환경설비학회
  3. The Literature of Indoor VOCs Characterization and Control Methodology, "Korea Air Cleaning Association", Korea Air Cleaning Association, ~ (2001)
  4. Lee Eun-Taek, "An analysis of Formaldehyde occurrence and emission rates", Air Cleaning Technology, 18(4), pp.14~25 (2005)
  5. 이세행, "회귀분석을 이용한 다중이용시설 실내오염물질 특성 연구", 한국환경분석학회지, 16(2), pp.123~131 (2013), 한국환경분석학회
  6. A Study on Indoor Air Pollution Characterization and Management, "The Ministry of Environment", The Ministry of Environment, ~ (2002)
  7. "The Ministry of Environment, 2010-24 ES 02130", ~ (2010)
  8. The Ministry of Environment, "Indoor Air Quality Guideline", ~ (2010)
  9. 유복희, "실내 건축재료에서의 포름알데히드 방출에 대한 온도 및 습도의 영향", 대한건축학회논문집 계획계, 26(07), pp.249~256 (2010), 대한건축학회

관련 논문AI추천

이 간행물의 다른 논문 (6건)