신축공동주택의 실내공기질 실태분석
An Indoor Air Quality Analysis in Newly Constructed Apartments
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study analyzes the indoor air quality inspections of newly constructed apartments by the Busan Institute of Health and Environment for the last three years (2021-2023). Of the 41 inspections, 33 exceeded the recommended standard, and the average excess rate was 80.5%. When classified by measuring households, 148 out of 332 exceeded the standards, whereas, the average excess rate by household was 44.6%. Benzene was exceeded in two out of the 332 households; therefore, the excess rate was only 0.6%. However, the relative standard deviation was the largest, showing as the highest item in the scattergram. The average concentration of toluene was 1,006.0 μg/m3, which was 100.6% of the recommended standard and was exceeded by 138 households; hence,ᅠ the excess rate was 41.6%. All six items(Formaldehyde, Benzene, Toluene, Ethylbenzene, Xylene, Styrene) reached the highest concentration in spring or summer when the indoor temperature increased. The average concentration of toluene in July was 1,922 μg/m3, close to 1.9 times the recommended standard; toluene is considered ᅠ an item of particular concern in summer. In the correlation analysis with indoor temperature, the formaldehyde coefficient of determination was 0.4855, regarded as somewhat significant; it was difficult to confirm the correlation with temperature for the other five items, including benzene. In correlation with relative humidity, formaldehyde showed the same tendency as indoor temperature, with a coefficient of determination of 0.4404, which is believed to be due to its small molecular weight and high solubility. Due to the chimney effect, high concentrations of volatile organic compounds could be confirmed at low atmospheric pressure in the upper floors, and this trend was most evident for formaldehyde. For most items(Formaldehyde, Benzene, Toluene, Ethylbenzene, Styrene), a negative correlation was confirmed in which the emission amount decreased as the number of households increased. For large apartment houses, it is believed that it is due to sufficient bake-out and flush- out according to the adequate construction period and the use of eco-friendly and high-end building materials. Small apartments are classified together with many small houses. The emission concentration of small houses is relatively high because the proportion of the surface area where pollutants are released is high.
Abstract
This study analyzes the indoor air quality inspections of newly constructed apartments by the Busan Institute of Health and Environment for the last three years (2021-2023). Of the 41 inspections, 33 exceeded the recommended standard, and the average excess rate was 80.5%. When classified by measuring households, 148 out of 332 exceeded the standards, whereas, the average excess rate by household was 44.6%. Benzene was exceeded in two out of the 332 households; therefore, the excess rate was only 0.6%. However, the relative standard deviation was the largest, showing as the highest item in the scattergram. The average concentration of toluene was 1,006.0 μg/m3, which was 100.6% of the recommended standard and was exceeded by 138 households; hence,ᅠ the excess rate was 41.6%. All six items(Formaldehyde, Benzene, Toluene, Ethylbenzene, Xylene, Styrene) reached the highest concentration in spring or summer when the indoor temperature increased. The average concentration of toluene in July was 1,922 μg/m3, close to 1.9 times the recommended standard; toluene is considered ᅠ an item of particular concern in summer. In the correlation analysis with indoor temperature, the formaldehyde coefficient of determination was 0.4855, regarded as somewhat significant; it was difficult to confirm the correlation with temperature for the other five items, including benzene. In correlation with relative humidity, formaldehyde showed the same tendency as indoor temperature, with a coefficient of determination of 0.4404, which is believed to be due to its small molecular weight and high solubility. Due to the chimney effect, high concentrations of volatile organic compounds could be confirmed at low atmospheric pressure in the upper floors, and this trend was most evident for formaldehyde. For most items(Formaldehyde, Benzene, Toluene, Ethylbenzene, Styrene), a negative correlation was confirmed in which the emission amount decreased as the number of households increased. For large apartment houses, it is believed that it is due to sufficient bake-out and flush- out according to the adequate construction period and the use of eco-friendly and high-end building materials. Small apartments are classified together with many small houses. The emission concentration of small houses is relatively high because the proportion of the surface area where pollutants are released is high.
참고문헌 (7)
- 김형진, "자동 베이크 아웃 시스템을 이용한 휘발성유기화합물 및 포름알데히드 저감효과", 공업화학학회지, 22(3), pp.291~295
- 국립환경과학원, "주택 실내공기질 관리를 위한 매뉴얼", ~ (2019)
- 실내공기질 공정시험방법 도출 연구 최종보고서, "대기환경학회", ~ (2004)
- 국립환경과학원, "실내공기질공정시험기준", ~ (2023)
- 2022년 다중이용시설 · 신축공동주택 · 대중교통차 량 · 실내공기질 지도 · 점검 결과, "환경부", ~ (2023)
- 환경부, "실내공기질 지도 · 점검 지침", ~ (2022)
- 곽진, "신축공동주택의 기간경과에 따른 실내공기질 변화연구", 부산광역시 보건환경연구원보 (2006)