실환경에서 공기청정기와 환기장치 운전에 따른 초미세먼지와 유해가스 제거 성능 평가
Evaluation of performance removal of PM2.5 and chemicals with respect to the operation of air cleaner and ventilation device
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this study, the reduction performance of PM2.5 and chemicals was evaluated when the ventilation device and air cleaner, which are representative air cleaning devices for apartment complexes, were operated individually or simultaneously. The clean air delivery rate (CADR) was highest when the ventilation device and air cleaner, were operated simultaneously. When each device was operated individually, the CADRs of the air cleaner, were higher than that of the ventilation device in all cases except CO2. The energy efficiency of the air cleaner was much higher than that of other devices. This is because the power consumption of the air cleaner, is relatively low compared to that of the mechanical ventilation device and its CADRs are high.
Abstract
In this study, the reduction performance of PM2.5 and chemicals was evaluated when the ventilation device and air cleaner, which are representative air cleaning devices for apartment complexes, were operated individually or simultaneously. The clean air delivery rate (CADR) was highest when the ventilation device and air cleaner, were operated simultaneously. When each device was operated individually, the CADRs of the air cleaner, were higher than that of the ventilation device in all cases except CO2. The energy efficiency of the air cleaner was much higher than that of other devices. This is because the power consumption of the air cleaner, is relatively low compared to that of the mechanical ventilation device and its CADRs are high.
참고문헌 (12)
- An, J. S., "Analysis of Fine Dust Removal Performance According to Types of Ventilation System in a Multifamily Residential Building", Journal of the Architectural Institute of Korea, 38(12), pp.273~282 (2022)[DOI]
- Han, B., "Field tests of indoor air cleaners for removal of PM2.5 and PM10 in elementary school’s classrooms in Seoul, Korea", Particle and Aerosol Research, 15(2), pp.79~90 (2019)[DOI]
- Kim, J. B., "Performance evaluation of air purifier by indoor air condition in the residential apartment", Journal of Odor and Indoor Environment, 18(2), pp.91~101 (2019)[DOI]
- Kim, M. J., "Development of “Pre-filter System” for Improving Particulate Matter Filtering Performance of Multi-unit Heat Recovery Ventilation System", Journal of The Korean Society of Living Environmental System, 26(5), pp.641~648 (2019)[DOI]
- Kim, Y., "Efficient energy saving scenarios for indoor PM2. 5 management in an apartment of South Korea", Toxics, 10, pp.609~ (2022)[DOI]
- Kwag, B. C., "Evaluation of Ventilation Performance of a Residential Unit for Different Sampling Points through Actual Field Tests", Land and Housing Review, 13(3), pp.93~106 (2022)[DOI]
- Noh, K. C., "Introduction on new concept of air cleaning per hour(ACH)for controlling contamination and infection, Air cleaning technology", Korea Air Cleaning Association, 138, pp.93~99 (2022)
- Noh, K. C., "Evaluation of proper particle cleaned air delivery per hour (PCH) for controlling indoor air quality in passenger car cabin", Par. Aerosol Res., 20(2), pp.47~56 (2024)[DOI]
- Park, H. -C., "A study on Development and Application of Sequential Control Algorithm of Ventilation and Air Cleaning System for Improving Indoor Air Quality in School Classroom", Journal of the architectural institute of Korea, Structure & Construction, 36(5), pp.187~194 (2020)[DOI]
- Shin, D., "The Effectiveness of a Mechanical Ventilation System for Indoor PM2. 5 in Residential Houses", Toxics, 11, pp.912~ (2023)[DOI]
- Song, Y. W., "Experimental study on the performance evaluation of photocatalytic ventilation systems for reducing indoor air pollutants", Doctor, pp.2022