Performance evaluation of Ocean Thermal Energy Conversion(OTEC) stabilization based on risk analysis

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기계공학

초록

Research and development of OTEC, a renewable energy power generation facility using seawater heat, is underway worldwide, and the development of a demonstration plant has been promoted in Korea. However, for the commercialization of OTEC, alternative operating scenarios must be derived for various environmental changes. Therefore, preemptively identifying the risk factors of the system, analyzing the effects of the system, establishing control items, and verifying the results through simulation are necessary. This study proposes a method to minimize risk factors along with a risk analysis of the risk factors of MW-scale OTEC, such as refrigerant leakage and riser loss. The selected OTEC was designed for 1070 kW-class facilities, and 36.6% of the total power is consumed by seawater pumps and refrigerant pumps. The refrigerant was assumed to be leaked owing to the opening of the valve to the top of the refrigerant tank, and the performance change was confirmed by assuming that the refrigerant leaked at an average rate of approximately 21 kg/s. In addition, the riser loss assumed a rapidly changing deep water temperature, and the system was operated to stop when the deep water temperature increased up to 18°C.

Abstract

Research and development of OTEC, a renewable energy power generation facility using seawater heat, is underway worldwide, and the development of a demonstration plant has been promoted in Korea. However, for the commercialization of OTEC, alternative operating scenarios must be derived for various environmental changes. Therefore, preemptively identifying the risk factors of the system, analyzing the effects of the system, establishing control items, and verifying the results through simulation are necessary. This study proposes a method to minimize risk factors along with a risk analysis of the risk factors of MW-scale OTEC, such as refrigerant leakage and riser loss. The selected OTEC was designed for 1070 kW-class facilities, and 36.6% of the total power is consumed by seawater pumps and refrigerant pumps. The refrigerant was assumed to be leaked owing to the opening of the valve to the top of the refrigerant tank, and the performance change was confirmed by assuming that the refrigerant leaked at an average rate of approximately 21 kg/s. In addition, the riser loss assumed a rapidly changing deep water temperature, and the system was operated to stop when the deep water temperature increased up to 18°C.

참고문헌 (17)

  1. L. A. Vega, "Encyclopedia of Sustainability Science and Technology" (2012), Springer
  2. H. S. LEE, "Design and experiment of the 20kW OTEC plant", Proceedings of KAOSTS Spring Conference, pp.2448~2452 (2014)
  3. 임승택, "해수유량변화에 따른 MW급 해수온도차발전시스템의 성능변화 동적 시뮬레이션", 동력시스템공학회지, 23(1), pp.48~56 (2019), 한국동력기계공학회[DOI]
  4. 권용주, "해상 부유식 1MW 해수온도차발전 시스템의 라이저 설계", 한국해양환경•에너지학회지, 18(1), pp.22~28 (2015), 한국해양환경·에너지학회
  5. J. B. Seo, "Performance evaluation and modification plan of the 1MW OTEC turbine", Korean Science for Marine Environment & Energy Fall Conference, pp.147~148 (2019)
  6. "Hazard Analysis Risk Assessment"[URL]
  7. International Organization for Standardization, "Space Systems Risk Management", ISO 17666, ~ (2016)
  8. 박상현, "Reliability evaluation of conceptual design for the dehydration package", Journal of Mechanical Science and Technology, 32(11), pp.5263~5271 (2018), 대한기계학회
  9. H. Noh, "Identification of potential hazardous events of unloading system and CO2 storage tanks of an intermediate storage terminal for the Korea clean carbon storage project 2025", International Journal of Safety and Security Engineering, 8(2), pp.258~265 (2018)
  10. X. -Y. Zhou, "Towards applicability evaluation of hazard analysis methods for autonomous ships", Ocean Engineering, 214, pp.1~19 (2020)
  11. Development of the utilization technology of deep seawater thermal energy (1 MW OTEC plant) Report, "Korea Research Institute of Ships & Ocean Engineering", ~ (2015)
  12. S. -H. Oh, "Subsystem hazard analysis on an offshore waste disposal facility", International Journal of Environmental Research and Public Health, 17(21), pp.7755~ (2020)
  13. N. Chemmangattuvalappil, "Basics of process simulation with Aspen HYSYS", Chemical Engineering Process Simulation, pp.233~ (2017)
  14. S. T. Lim, "Simulation data of regional economic analysis of otec for applicable area", Processes, 8(9), pp.1107~ (2020)
  15. W. L. Luyben, "Liquid level control: Simplicity and complexity", Journal of Process Control, 86, pp.57~64 (2020)
  16. R. Adiputra, "Stability based approach to design cold-water pipe (CWP) for ocean thermal energy conversion (OTEC)", Applied Ocean Research, 92 (2019)
  17. M. L. Syamsuddin, "OTEC potential in the Indonesian seas", Energy Procedia, 65, pp.215~222 (2015)

관련 논문AI추천

이 간행물의 다른 논문 (5건)