본문 바로가기
KERD
논문KCI 등재

Wettability and drug delivery of functionally graded nano-micro porous titanium surface

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

STATEMENT OF PROBLEM: It is known that an anodic oxidation technique, one of the methods for the implant surface treatment, remarkably increased surface area, enhanced wettability and accelerated the initial bone healing. Purpose: This study was performed to evaluate the wettability of anodized titanium surface which has a nanotubular structure, to assess osseointegration after the placement of implant with nano-size tubes on tibia of rats and to analyze quantitatively transferable rhBMP-2 on each surface. MATERIAL AND METHOD: Four different kinds of surface-treated titanium discs (polished (machined surface) group, micro (blasting surface) group, nano (anodizedmachined surface) group, and nano-micro (anodized-blasting surface) group) were fabricated (n=10). Three different media were chosen to measure the surface contact angles; distilled water, plasma and rhBMP-2 solution. After a single drop (0.025 ㎖) of solution, the picture was taken with the image camera, and contact angle was measured by using image analysis system. For the test of osseointegration, 2 kinds of anodized surface (anodized-machined surface, anodized-blasting surface) implants having 2.0 ㎜ in diameter and 5.0 ㎜ in length inserted into the tibia of Wistar rats. After 3 weeks, tibia were harvested and the specimens were stained with hematoxylin and eosin for histological analysis. To test the possibility of drug delivery, after soaking sample groups in the concentration of 250 ng/㎖ of rhBMP-2 for 48 hours, the excess solution of rhBMP-2 were removed. After that, they were lyophilized for 24 hours, and then the rhBMP-2 on the surface of titanium was resolved for 72 hours in PBS. All the extracted solution was analyzed by ELISA. One-way analysis of variance (ANOVA) was performed on the data. RESULTS: The wettability is improved by anodic oxidation. The best wettability was shown on the nano-micro group, and it was followed by nano group, micro group, and polished group. In the histological findings, all implants showed good healing and the new bone formation were observed along the implant surface. After 3 days, nano-micro group delivered the most amount of rhBMP-2, followed by nano group, micro group, and polished group. CONCLUSION: It indicated that anodic oxidation on blasting surface produce functionally graded nano-micro porous structure and enhance hydrophilicity of the surface and osseointegration. The findings suggest that the nano-micro porous structure could be a useful carrier of osteogenic molecules like rhBMP-2.

Abstract

STATEMENT OF PROBLEM: It is known that an anodic oxidation technique, one of the methods for the implant surface treatment, remarkably increased surface area, enhanced wettability and accelerated the initial bone healing. Purpose: This study was performed to evaluate the wettability of anodized titanium surface which has a nanotubular structure, to assess osseointegration after the placement of implant with nano-size tubes on tibia of rats and to analyze quantitatively transferable rhBMP-2 on each surface. MATERIAL AND METHOD: Four different kinds of surface-treated titanium discs (polished (machined surface) group, micro (blasting surface) group, nano (anodizedmachined surface) group, and nano-micro (anodized-blasting surface) group) were fabricated (n=10). Three different media were chosen to measure the surface contact angles; distilled water, plasma and rhBMP-2 solution. After a single drop (0.025 ㎖) of solution, the picture was taken with the image camera, and contact angle was measured by using image analysis system. For the test of osseointegration, 2 kinds of anodized surface (anodized-machined surface, anodized-blasting surface) implants having 2.0 ㎜ in diameter and 5.0 ㎜ in length inserted into the tibia of Wistar rats. After 3 weeks, tibia were harvested and the specimens were stained with hematoxylin and eosin for histological analysis. To test the possibility of drug delivery, after soaking sample groups in the concentration of 250 ng/㎖ of rhBMP-2 for 48 hours, the excess solution of rhBMP-2 were removed. After that, they were lyophilized for 24 hours, and then the rhBMP-2 on the surface of titanium was resolved for 72 hours in PBS. All the extracted solution was analyzed by ELISA. One-way analysis of variance (ANOVA) was performed on the data. RESULTS: The wettability is improved by anodic oxidation. The best wettability was shown on the nano-micro group, and it was followed by nano group, micro group, and polished group. In the histological findings, all implants showed good healing and the new bone formation were observed along the implant surface. After 3 days, nano-micro group delivered the most amount of rhBMP-2, followed by nano group, micro group, and polished group. CONCLUSION: It indicated that anodic oxidation on blasting surface produce functionally graded nano-micro porous structure and enhance hydrophilicity of the surface and osseointegration. The findings suggest that the nano-micro porous structure could be a useful carrier of osteogenic molecules like rhBMP-2.

참고문헌 (28)

  1. Lampin M, "Correlation between substratum roughness and wettability, cell adhesion, and cell migration", Biomed Mater Res, 36, pp.99~108 (1997)
  2. Cho CS, "Difference in adhesion and proliferation of fibroblast between Langmuir-Blodgett films and cast surfaces of poly (gamma-benzyl L-glutamate)", poly(ethylene oxide) diblock copolymer, 1996, pp.32, 425~432
  3. Smith DC, "Dental implant materials. II. Preparative procedures and surface spectroscopic studies", J Biomed Mater Res, 25, pp.1069~1084 (1991)
  4. Lim YJ, "Initial contact angle measurements on dental materials", Bio-Medical Materials and Engineering, 11, pp.325~341 (2001)
  5. Mekayarajjananonth T, "Contact angle measurement on dental implant biomaterials", J Oral Implantology, 25, pp.230~236 (1999)
  6. Berglundh T, "De novo alveolar bone formation adjacent to endosseous implants. A model study in the dog", Clin Oral Impl Res, 14, pp.251~262 (2003)
  7. Schenk RK, "Healing pattern of bone regeneration in membrane-protected defects. A histologic study in the canine mandible", Int. J. Oral & Maxillo. Impl, 9, pp.13~29 (1994)
  8. Ameen AP, "The surface analysis of implant materials. 1. The surface composition of a titanium dental implant material", Clin Oral Implants Res, 4, pp.144~150 (1993)
  9. Baier RE, "Adhesion: mechanisms that assist or impede it", Science, 162, pp.1360~1368 (1968)
  10. Yang B, "Preparation bioactive titanium metal via anodic oxidation treatment", Biomaterials, 25, pp.1003~1010 (2004)
  11. Balaur E, "Tailoring the wettability of TiO2 nanotube layers", Electrochemistry Communications, 7, pp.1066~1070 (2005)
  12. Grinnell F, "Cellular adhesiveness and extracellular substrata", Int Rev Cytol, 53, pp.65~144 (1978)
  13. Aronov D, "Tunable hydroxyapatite wettability: Effect on adhesion of biological molecules", Process Biochemistry, 41, pp.2367~2372 (2006)
  14. Hosseinkhani H, "Bone regeneration through controlled release of bone morphogenetic protein-2 from 3-D tissue engineered nano-scaffold", J Controlled Release, 117, pp.380~386 (2007)
  15. Woo BH, "Enhancement of bone growth by sustained delivery of recombinant human bone morphogenetic protein-2 in a polymeric matrix", Pharmaceutical Research, 18, pp.1747~1753 (2001)
  16. Esposito M, "Failure patterns of four ossointergrated oral implant systems", J Mater Sci Mat Med, 8, pp.843~847 (1997)
  17. Albrektsson T, "Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants", J Periodontal, 59, pp.287~296 (1988)
  18. Keller JC, "In vitro cell attachment to characterized cpTi surfaces", J Adhesion, 28, pp.115~133 (1989)
  19. Keller JC, "Characterization of sterilized CP titanium implant surfaces", Int J Oral Maxillofac Implants, 5, pp.360~369 (1990)
  20. Eckert SE, "Validation of dental implant systems through a review of the literature supplied by system manufacturers", J Prosthet Dent, 77, pp.271~279 (1997)
  21. Kim HS, Park SW, Lee KM, "Mechanism of Formation and Characteristics of TiO2 Nanotube on Titanium by Anodizing", 석사, pp.2007
  22. Montanaro L, "In vitro effects on MG63 osteoblast-like cells following contact with two roughness-differing fluorohydroxyapatitecoated titanium alloys", Biomaterials, 23, pp.3651~2659 (2002)
  23. Rodriguez R, "In vitro osteoblast response to anodized titanium and anodized titanium followed by hydrothermal treatment", J Biomed Mater Res, 65, pp.352~358 (2003)
  24. Zhu X, "Surface characteristics and structure of anodic oxide films containing Ca and P on a titanium implant material", J Biomed Mater Res, 60, pp.333~338 (2002)
  25. Clokie CM, "Morphologic and radioautographic studies of bone formation in relation to titanium implants using the rat tibia as a model", Int J Oral Maxillofac Implants, 10, pp.155~165 (1995)
  26. Yanagisawa I, "Effects o“f wettability” of biomaterials on culture cells", J Oral Implantol, 15, pp.168~177 (1989)
  27. Sachse A, "Osteointegration of hydroxyapatite-titanium implants coated with nonglycosylated recombinant human bone morphogenetic protein-2 (BMP-2) in aged sheep", Bone, 37, pp.699~710 (2005)
  28. Liu Y, "BMP-2 liberated from biomimetic implant coatings induces and sustains direct ossification in an ectopic rat model", Bone, 36, pp.745~757 (2005)

관련 논문AI추천