본문 바로가기
KERD
논문KCI 등재

Effect of number of implants and cantilever design on stress distribution in three-unit fixed partial dentures: A three-dimensional finite element analysis

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. 4.1×10 mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three 4.1×10 mm implants and fixed prosthesis with no pontic, model 1-2 which has two 4.1×10 mm implants and fixed prosthesis with a central pontic and model 1-3 which has two 4.1×10 mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three 4.1×10 mm implants and fixed prosthesis with no pontic, model 2-2 which has two 4.1×10 mm implants and fixed prosthesis with a central pontic and model 2-3 which has two 4.1×10 mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N , it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

Abstract

STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. 4.1×10 mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three 4.1×10 mm implants and fixed prosthesis with no pontic, model 1-2 which has two 4.1×10 mm implants and fixed prosthesis with a central pontic and model 1-3 which has two 4.1×10 mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three 4.1×10 mm implants and fixed prosthesis with no pontic, model 2-2 which has two 4.1×10 mm implants and fixed prosthesis with a central pontic and model 2-3 which has two 4.1×10 mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N , it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

참고문헌 (37)

  1. Becker CM, "Implant-retained cantilever fixed prosthesis: Where and When", J Prosthet Dent, 84, pp.432~435 (2000)
  2. English CE, "Biomechanical concerns with fixed partial dentures involving implants", Implant Dent, 2, pp.221~242 (1993)
  3. Buser D, "The original one-stage dental implant system and its clinical application", Periodontology, 17, pp.106~118 (2000)
  4. Misch CE, "Dental Implant Prosthetics", pp.184~ (2005), Mosby
  5. Rangert B, "Bending overload and implant fracture: a retrospective clinical analysis", Int J Oral Maxillofac Implants, 10, pp.326~334 (1995)
  6. Sullivan D, "Prosthetic considerations for the utilization of osseointegrated fixtures in the partially edentulous arch", Int J Oral Maxillofac Implants, 1, pp.39~45 (1986)
  7. Lindquist LW, "A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clinical results and marginal bone loss", Clin Oral Impl Res, 7, pp.329~336 (1996)
  8. Lambrecht JT, "Longterm evaluation of submerged and nonsubmerged ITI solid-screw titanium implants: A 10-year life table analysis of 468 implants", Int J Oral Maxillofac Implants, 18, pp.826~834 (2003)
  9. Romeo E, "Implant-supported fixed cantilever prostheses in partially edentulous arches. a seven-year prospective study", Clin Oral Impl Res, 14, pp.303~311 (2003)
  10. Becker CM, "Cantilever fixed prostheses utilizing dental implants: a 10-year retrospective analysis", Quintessence Int, 35, pp.437~441 (2004)
  11. White SN, "Effect of cantilever length on stress transfer by implant-supported prostheses", J Prosthet Dent, 71, pp.493~499 (1994)
  12. Tashkandi EA, "Analysis of strain at selected bone sites of a cantilevered implant-supported prosthesis", J Prosthet Dent, 76, pp.158~164 (1996)
  13. Wang S, "Load distribution on implants with a cantilevered superstructure : an in vitro pilot study", Implant Dent, 5, pp.36~42 (1996)
  14. Stegaroiu R, "Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis", Int J Oral Maxillofac Implants, 13, pp.82~90 (1998)
  15. Yokoyama S, "The influence of implant location and length on stress distribution for three-unit implant-supported posterior cantilever fixed partial dentures", J Prosthet Dent, 91, pp.234~240 (2004)
  16. Tarnow DP, "The effect of the distance from the contact point to the crest of bone on the presence or absence of the interproximal dental papilla", J Periodontol, 63, pp.995~996 (1992)
  17. Tarnow SC, "The effect of interimplant distance on the height of inter-implant bone crest", J Periodontol, 71, pp.546~549 (2000)
  18. Kwon YS, "Comparison of maximum occlusal forces on osseointegrated implant supported fixed prostheses and natural teeth", J Korean Acad Prosthodont, 43, pp.498~510 (2005)
  19. Eskitascioglu G, "The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study", J Prosthet Dent, 91, pp.144~150 (2004)
  20. Ak a K, "Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism", J Oral Rehabil, 29, pp.350~356 (2002)
  21. Geng JP, "Application of finite element analysis in implant dentistry: A review of the literature", J Prosthet Dent, 85, pp.585~598 (2001)
  22. Eranslan O, "Effects of cantilever design and material on stress distribution in fixed partial dentures-a finite element analysis", J Oral Rehabil, 32, pp.273~278 (2005)
  23. Sevimay M, "Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown", J Prosthet Dent, 93, pp.227~234 (2005)
  24. Rangert B, "Forces and moments on Branemark implants", Int J Oral Maxillofac Implants, 4, pp.241~247 (1989)
  25. Kim Y, "Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale", Clin Oral Impl Res, 16, pp.26~35 (2005)
  26. Haraldson T, "Bite force and oral function in patients with osseointegrated oral implants", Scand J Dent Res, 85, pp.200~208 (1977)
  27. Haraldson T, "A 10-year follow-up study of the masticatory system after treatment with osseointegrated implant bridges", Scand J Dent Res, 96, pp.243~252 (1988)
  28. Jemt T, "Occlusal force and mandibular movements in patients with removable overdentures and fixed prostheses supported by implants in the maxilla", Int J Oral Maxillofac Implants, 8, pp.301~308 (1993)
  29. Mericske-stern R, "In vivo measurements of maximal occlusal force and minimal pressure threshold on overdentures supported by implants or natural roots: a comparative study, part 1", Int J Oral Maxillofac Implants, 8, pp.641~649 (1993)
  30. Mericske-stern R, "In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants", Clin Oral Impl Res, 7, pp.153~161 (1996)
  31. Fontijn-Tekamp FA, "Bite forces with mandibular implant-retained overdentures", J Dent Res, 77, pp.1832~1839 (1998)
  32. Mericske-stern R, "Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants", Int J Oral Maxillofac Implants, 10, pp.345~354 (1995)
  33. Koolstra JH, "A three-dimensional mathematical model of the human masticatory system predicting maximum possible bite forces", J Biomechanics, 21, pp.563~576 (1988)
  34. van Eijden TMGJ, "Three-dimensional analyses of human bite-force magnitude and moment", Archs oral Biol, 36, pp.535~539
  35. Misch CE, "Dental Implant Prosthetics", pp.100~101 (2005), Mosby
  36. Holmgren EP, "Evaluation parameters of osseointegrated dental implants using finite element analysis-A two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction", J Oral Implantol, 24, pp.80~88 (1998)
  37. Iplik ioglu H, "Comparative evaluation of the effect of diameter, length, and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone", J Dent, 30, pp.41~46 (2002)

관련 논문AI추천

Three dimensional finite element analysis of the stress distribution around the mandibular posterior implant during non-working movement according to the amount of cantilever김명래, 김선종, 김현주, 박은진, 박지만대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제5호두 개의 임플란트를 이용한 3본 고정성 국소의치에서 가공치 위치에 따른 하악골에서의 응력 분포 및 변형에 관한 삼차원 유한요소법적 연구김규남, 김동수, 김일규, 박태환, 손충렬, 장금수대한구강악안면외과학회 · 대한구강악안면외과학회지2008 · 제34권 제2호Three-dimensional finite element analysis of buccally cantilevered implantsupported prostheses in a severely resorbed mandible권호범, 김명주, 임영준, Ghaith Alom대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제1호임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구이우현, 임종화, 조인호대한턱관절교합학회 · 구강회복응용과학지2010 · 제26권 제3호Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis studyParamba Hitendrabhai Acharya, Sareen Subhash Duseja, Vilas Valjibhai Patel, Vishal Rajendrabhai Chauhan대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제2호Effects of implant alignment and load direction on mandibular bone and implant: finite element analysis박찬, 박상원, 양홍서, 윤귀덕, 임현필, 정현주대한턱관절교합학회 · 구강회복응용과학지2020 · 제36권 제3호

이 간행물의 다른 논문 (9건)