Effect of cyclic loading on axial displacement of abutment into implant with internal tapered connection: a pilot study

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: To evaluate the axial displacement of implant-abutment assembly after cyclic loading in internal tapered connection system. Materials and methods: External butt-joint connection implant and internal tapered connection implant were connected with three types of abutment for cement-retained prostheses, i.e. external type abutment (Ext group), internal tapered 1-piece abutment (Int-1 group), and internal tapered 2-piece abutment (Int-2 group). For each group, 7 implants and abutments were used. The implantabutments assemblies were clamped into the implant holder for vertical loads. A dynamic cyclic loading was applied for 150 ± 10 N at a frequency of 4 Hz. The amount of axial displacement of the abutment into the implant was calculated at each cycle of 0, 5, 10, 50, 100, 1,000, 5,000, and 10,000. A repeated measures analysis of variance (ANOVA) for the overall effect of cyclic loading and the pattern analysis by linear mixed model were used for statistical analysis. Differences at P<.05 were considered statistically significant. Results: The mean axial displacement after 10,000 cycles were 0.714 ± 0.488 ㎛ in Ext group, 5.286 ± 1.604 ㎛ in Int-1 group, and 11.429 ± 1.902 ㎛ in Int-2 group. In the pattern analysis, Int-1 and Int-2 group showed continuous axial displacement at 10,000 cycles. There was no declining pattern of axial displacement in the Ext group. Conclusion: The pattern of linear mixed model in Ext group showed no axial displacement. There were continuous axial displacements in abutment-implant assemblies in the Int-1 and Int-2 group at 10,000 cycles. More axial displacement was found in Int-2 group than in Int-1 group.

Abstract

Purpose: To evaluate the axial displacement of implant-abutment assembly after cyclic loading in internal tapered connection system. Materials and methods: External butt-joint connection implant and internal tapered connection implant were connected with three types of abutment for cement-retained prostheses, i.e. external type abutment (Ext group), internal tapered 1-piece abutment (Int-1 group), and internal tapered 2-piece abutment (Int-2 group). For each group, 7 implants and abutments were used. The implantabutments assemblies were clamped into the implant holder for vertical loads. A dynamic cyclic loading was applied for 150 ± 10 N at a frequency of 4 Hz. The amount of axial displacement of the abutment into the implant was calculated at each cycle of 0, 5, 10, 50, 100, 1,000, 5,000, and 10,000. A repeated measures analysis of variance (ANOVA) for the overall effect of cyclic loading and the pattern analysis by linear mixed model were used for statistical analysis. Differences at P<.05 were considered statistically significant. Results: The mean axial displacement after 10,000 cycles were 0.714 ± 0.488 ㎛ in Ext group, 5.286 ± 1.604 ㎛ in Int-1 group, and 11.429 ± 1.902 ㎛ in Int-2 group. In the pattern analysis, Int-1 and Int-2 group showed continuous axial displacement at 10,000 cycles. There was no declining pattern of axial displacement in the Ext group. Conclusion: The pattern of linear mixed model in Ext group showed no axial displacement. There were continuous axial displacements in abutment-implant assemblies in the Int-1 and Int-2 group at 10,000 cycles. More axial displacement was found in Int-2 group than in Int-1 group.

참고문헌 (23)

  1. Jemt T, "Fixed implant-supported prostheses in the edentulous maxilla. A five-year follow-up report", Clin Oral Implants Res, 5, pp.142~147 (1994)
  2. Buser D, "Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants", Clin Oral Implants Res, 8, pp.161~172 (1997)
  3. Nelson K, "A retrospective analysis of sandblasted, acid-etched implants with re-duced healing times with an observation period of up to 5 years", Int J Oral Max Impl, 23, pp.726~732 (2008)
  4. Goodacre CJ, "Clinical complications with implants and implant prostheses", J Prosthet Dent, 90, pp.121~132 (2003)
  5. Jemt T, "A 3-year follow-up study on single implant treatment", J Dent, 21, pp.203~208 (1993)
  6. Sutter F, "The New Restorative Concept of the ITI Dental Implant System: Design and Engineering", Int J Periodont Rest, 13, pp.408~431 (1993)
  7. Norton MR, "Assessment of cold welding properties of the internal conical interface of two commercially available implant systems", J Prosthet Dent, 81, pp.159~166 (1999)
  8. Khraisat A, "Fatigue resistance of two implant", abutment joint designs, 2002, pp.88, 604~610
  9. Merz BR, "Mechanics of the implantabutment connection: An 8-degree taper compared to a butt joint connection", Int J Oral Max Impl, 15, pp.519~526 (2000)
  10. Kitagawa T, "Influence of implant", abutment joint designs on abutment screw loosening in a dental implant system, 2005, pp.75, 457~463
  11. Norton MR, "An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design", Clin Oral Implants Res, 8, pp.290~298 (1997)
  12. Schwarz MS, "Mechanical complications of dental implants", Clin Oral Implants Res, 11, pp.156~158 (2000)
  13. Bozkaya D, "Mechanics of the tapered interference fit in dental implants", J Biomech, 36, pp.1649~1658 (2003)
  14. Dailey B, "Axial Displacement of Abutments into Implants and Implant Replicas, with the Tapered Cone-Screw Internal Connection, as a Function of Tightening Torque", Int J Oral Max Impl, 24, pp.251~256 (2009)
  15. Kim KS, "Variation in the total lengths of abutment", implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection, 2011, pp.22, 834~839
  16. Lee JH, "Axial displacements in external and internal implant-abutment connection", Clin Oral Implants Res, 2012, pp.1~7 (2012)
  17. Kim SK, "Screw Loosening with Interchangeable Abutments in Internally Connected Implants After Cyclic Loading", Int J Oral Max Impl, 27, pp.42~47 (2012)
  18. Richter E-J, "In Vivo Vertical Forces on Implants", Int J Oral Max Impl, 10, pp.120~140 (1995)
  19. Rosentritt M, "Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures", Dental materials: official publication of the Academy of Dental Materials, 22, pp.176~182 (2006)
  20. "lme4: Linear mixed-effects models using S4 classes. R package version 0.999999-2"[URL]
  21. Siamos G, "Relationship between implant preload and screw loosening on implant-supported prostheses", J Oral Implantol, 28, pp.67~73 (2002)
  22. Bakaeen LG, "The effect of implant diameter, restoration design, and occlusal table variations on screw loosening of posterior single-tooth implant restorations", J Oral Implantol, 27, pp.63~72 (2001)
  23. Wiskott HWA, "Stress Fatigue: Basic Principles and Prosthodontic Implications", Int J Prosthodont, 8, pp.105~116 (1995)

관련 논문AI추천

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force곽재영, 김성균, 허성주, Yuseung Yi대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제6호Influence of the implant-abutment connection design and diameter on the screw joint stability신현모, 윤미정, 전영찬, 정창모, 허중보, Brian Myung Chang대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제2호The assessment of abutment screw stability between the external and internal hexagonal joint under cyclic loading김성훈, 양재호, 이재봉, 이태식, 한중석대한치과보철학회 · 대한치과보철학회지2008 · 제46권 제6호Screw loosening and changes in removal torque relative to abutment screw length in a dental implant with external abutment connection after oblique cyclic loading이주희, 차현석대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제6호Digital evaluation of axial displacement by implant-abutment connection type: an in vitro study김성준, 이규복, 손큰바다대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제5호Influence of internal connection length on screw loosening in internal connection implants김선재, 김성태, 김지선, 김현철, 문홍석, 박영범, 이재훈, 최현민대한치과보철학회 · 대한치과보철학회지2017 · 제55권 제3호

이 간행물의 다른 논문 (14건)