The purpose of this study were to constructed multi-level cervical spine finite element (FE) model and to investigate changes in load distribution and range of motion (ROM) at index level and adjacent levels at immediately after anterior cervical discectomy and fusion (ACDF) and after full bony union using constrained and semi-constrained cervical plate systems(dynamic plate, variable screw). A FE model of intact cervical spine (C3-6) was created from computer tomography (CT) images of the healthy adult (male, 26 years, no pathologies). The post-op FE models (C5-6 with ACDF, cage with bone graft) were constructed by modifying a intact cervical FE model. Four different configurations of the model were considered: Type 1-Rigid plate+Fixed screw, Type II-Rigid plate+Variable screw, Type III-Dynamic plate+ Fixed screw, Type IV-Dynamic plate+Variable screw. The bone-cage and bone screw interface behavior were accomplished via 'tie' contact condition and friction coefficient of 0.2 to assume fusion and non-fusion, respectively. The inferior endplate of C6 vertebral body was constrained in all directions. Loading condition used hybrid protocol with follower load of 73.6N at superior endplate of C3 vertebral body. In non-fusion cases, load at the bone graft increased from Type I to IV (2.3→6.8%, flexion; 2.9→7.6%, extension) while plate load was reduced (91.4→75.7%, 89.4→71.8%, respectively) and the rest went through the facets. Similar trend was observed in fusion cases at bone graft/fusion (6.4→12.4%, 7.4→10.4%) and plate (83.3→71.3%, 80.6→67.2%). As compared to the intact spine, ROM of Type IV was most similar to those of the intact spine; least reduction at the index (-36%) and least increase (+7%) at the adjacent level. This was followed by Type III, II, and I and this trend was more evident in non-fusion cases than after fusion. With more degree of freedom (Type I→Type IV), the load sharing became more favorable for bony union across the graft/cage area. Simultaneously, excessive changes in motion at the index and adjacent levels were reduced. These biomechanical changes could contribute to promoting fusion process. Our study predicted more biomechanically sound characteristics of semi-constrained cervical plate system as compared to the conventional constrained system in terms of load sharing and motion kinematics.

Abstract

The purpose of this study were to constructed multi-level cervical spine finite element (FE) model and to investigate changes in load distribution and range of motion (ROM) at index level and adjacent levels at immediately after anterior cervical discectomy and fusion (ACDF) and after full bony union using constrained and semi-constrained cervical plate systems(dynamic plate, variable screw). A FE model of intact cervical spine (C3-6) was created from computer tomography (CT) images of the healthy adult (male, 26 years, no pathologies). The post-op FE models (C5-6 with ACDF, cage with bone graft) were constructed by modifying a intact cervical FE model. Four different configurations of the model were considered: Type 1-Rigid plate+Fixed screw, Type II-Rigid plate+Variable screw, Type III-Dynamic plate+ Fixed screw, Type IV-Dynamic plate+Variable screw. The bone-cage and bone screw interface behavior were accomplished via 'tie' contact condition and friction coefficient of 0.2 to assume fusion and non-fusion, respectively. The inferior endplate of C6 vertebral body was constrained in all directions. Loading condition used hybrid protocol with follower load of 73.6N at superior endplate of C3 vertebral body. In non-fusion cases, load at the bone graft increased from Type I to IV (2.3→6.8%, flexion; 2.9→7.6%, extension) while plate load was reduced (91.4→75.7%, 89.4→71.8%, respectively) and the rest went through the facets. Similar trend was observed in fusion cases at bone graft/fusion (6.4→12.4%, 7.4→10.4%) and plate (83.3→71.3%, 80.6→67.2%). As compared to the intact spine, ROM of Type IV was most similar to those of the intact spine; least reduction at the index (-36%) and least increase (+7%) at the adjacent level. This was followed by Type III, II, and I and this trend was more evident in non-fusion cases than after fusion. With more degree of freedom (Type I→Type IV), the load sharing became more favorable for bony union across the graft/cage area. Simultaneously, excessive changes in motion at the index and adjacent levels were reduced. These biomechanical changes could contribute to promoting fusion process. Our study predicted more biomechanically sound characteristics of semi-constrained cervical plate system as compared to the conventional constrained system in terms of load sharing and motion kinematics.

참고문헌 (23)

  1. 박원만, "인공 추간판 치환술 후 경추의 생체역학적 특성", 대한기계학회논문집 A, 33(7), pp.637~644 (2009), 대한기계학회
  2. Samartzis D, "Comparison of allograft to autograft in multilevel anterior cervical discectomy and fusion with rigid plate fixation", Spine J, 3, pp.451~459 (2003)
  3. 송경진, "퇴행성 경추 질환에서 자가 장골을 이용한 정방 유합술과 전방 금속판 보강술과의 비교", 대한정형외과학회지, 43(3), pp.338~346 (2008), 대한정형외과학회
  4. Pitzen TR, "Implant complications, fusion, loss of lordosis, and outcome after anterior cervical plating with dynamic or rigid plates", Spine, 34, pp.641~646 (2009)
  5. Hong SW, "A comparison of fixed-hole and slotted-hole dynamic plates for anterior cervical discectomy and fusion", J of Spinal Disord Tech, 23, pp.22~26 (2010)
  6. Rapoff AJ, "Load sharing in Premier and Zephir anterior cervical plates", Spine, 15, pp.2648~2650 (2003)
  7. Dubois CM, "Static versus dynamic plating for multilevel anterior cervical discectomy and fusion", Spine J, 7, pp.188~193 (2007)
  8. Fogel GR, "In vitro evaluation of stiffness and load sharing in a two-level corpectomy: comparison of static and dynamic cervical plates", Spine J, 10, pp.417~421 (2010)
  9. Kim H, "Effects of nonlinearity in the materials used for the semi-rigid pedicle screw systems on biomechanical behaviors of the lumbar spine after surgery", Biomedical Mater, 6, pp.055005~ (2011)
  10. Faizan A, "Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation", Eur Spine J, 21(Suppl), pp.653~662 (2012)
  11. Zhang QH, "Finite element analysis of moment-rotation relationships for human cervical spine", J Biomech, 39, pp.189~193 (2006)
  12. Galbusera F, "Cervical spine biomechanics following implantation of a disc prosthesis", Med Eng Phys, 30, pp.1127~1133 (2008)
  13. Hussain M, "Screw angulation affects bone-screw stresses and bone graft load sharing in anterior cervical corpectomy fusion with a rigid screw-plate construct: a finite element model study", Spine J, 9, pp.1016~1023 (2009)
  14. Ha SK, "Finite element modeling of multi-level cervical spinal segments (C3–C6) and biomechanical analysis of an elastomer-type prosthetic disc", Med Eng Phys, 28, pp.534~541 (2006)
  15. Calamaz M, "A new material model for 2D numerical simulation of serrated chip formation when machining titanium alloy Ti-6Al-4V", International Journal of Machine Tool &Manufacture, 48, pp.275~288 (2008)
  16. Polikeit A, "Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis", Eur Spine J, 12, pp.413~420 (2003)
  17. Palepu V, "Cervical spine stability following anterior plate fixation is affected by screw implantation technique: a comparative finite element study", 57th Annual Meeting of the Orthopaedic Research Society (2011)
  18. Vadapalli S, "Biomechanical rationale for using polyetheretherketone (PEEK)spacers for lumbar interbody fusion–a finite element study", Spine, 31(26), pp.E992~998 (2006)
  19. Panjabi MM, "Hybrid multidirectional test method to evaluate spinal adjacent-level effects", Clin Biomech, 22, pp.257~265 (2007)
  20. Morrissy RT, "Measurement of the Cobb angle on radiographs of patients who have scoliosis. Evaluation of intrinsic error", J Bone Joint Surg Am, 72, pp.320~327 (1990)
  21. Panjabi MM, "Mechanical properties of the human cervical spine as shown by three-dimensional load–displacement curves", Spine, 26, pp.2692~2700 (2001)
  22. Pelker RR, "Cervical spine stabilization. A three-dimensional, biomechanical evaluation of rotational stability, strength, and failure mechanisms", Spine, 16, pp.117~122 (1991)
  23. Moroney SP, "Load-displacement properties of lower cervical spine motion segments", J Biomech, 21, pp.769~779 (1988)

관련 논문AI추천

이 간행물의 다른 논문 (6건)