초록

The aim of this study is to understand the characteristics of indoor air pollutants and provide information about the present Indoor Air Quality(IAQ) in 104 public facilities from January 2011 to December 2012. The measured air pollutants are PM10, HCHO(formaldehyde), CO, CO2, and total airborne bacteria(TAB). And the effects of environmental factors such as temperature, humidity and construction characteristics were analyzed in relation to the measured concentrations. The results of this study showed that the mean concentration of PM10, CO2, HCHO, CO, and TAB were 55.3 /, 558.6 ppm, 31.0 /, 1.2 ppm, and 561.3 CFU/, respectively. The correlation analysis showed that CO2 and HCHO (r=0.497, p<0.01), CO2 and TAB (r=0.468,p<0.01), and PM10 and CO (r=0.342, p<0.01) were significant. The result of regression analysis was found that the influence factors associated with the concentration of PM10, HCHO, and TAB were the year of building construction, the temperature and the humidity

Abstract

The aim of this study is to understand the characteristics of indoor air pollutants and provide information about the present Indoor Air Quality(IAQ) in 104 public facilities from January 2011 to December 2012. The measured air pollutants are PM10, HCHO(formaldehyde), CO, CO2, and total airborne bacteria(TAB). And the effects of environmental factors such as temperature, humidity and construction characteristics were analyzed in relation to the measured concentrations. The results of this study showed that the mean concentration of PM10, CO2, HCHO, CO, and TAB were 55.3 /, 558.6 ppm, 31.0 /, 1.2 ppm, and 561.3 CFU/, respectively. The correlation analysis showed that CO2 and HCHO (r=0.497, p<0.01), CO2 and TAB (r=0.468,p<0.01), and PM10 and CO (r=0.342, p<0.01) were significant. The result of regression analysis was found that the influence factors associated with the concentration of PM10, HCHO, and TAB were the year of building construction, the temperature and the humidity

참고문헌 (20)

  1. Y. Ataka, , wIndoor Air 2004, 14(8), pp.51~64 (2004)
  2. S. C. Lee, , Chemosphere, 109~113 (2000)
  3. The world health report, Reducing risks promoting healthy life, "WHO", ~ (2002)
  4. Human exposure assessment for airbone pollutants, "National Academy of Sciences", ~ (1993)
  5. 김성신, , 한국생활환경학회 춘계학술지, pp.54~55 (1997)
  6. 김미경, , 한국환경위생학회지, 15(2), pp.1~9 (1989)
  7. 원운재, , 강원도보건환경연구원보, 17, pp.67~73 (2006)
  8. 김윤신, , 대한의학학회지, 32(12), pp.1279~1285 (1989)
  9. 이주상, , 대한위생학회지, 17(3), pp.67~74 (2002)
  10. 류인철, "다중이용시설 실내공기질 특성 및 건강위해성평가에 대한 연구", 박사, 지구환경공학, pp.2010
  11. 서울시 다중이용시설의 실내공기질 실태조사 및 관리방안에 대한 연구, "서울시정개발연구원", ~ (2004)
  12. 백성옥, , 한국대기환경학회지, 14(4), pp.343~360 (1998)
  13. 김신도, "실내공간 실내공기오염 특성 및 관리방법 연구" (2002)
  14. 김윤신, "다중이용시설에서의 실내공기질 조사", 한국실내환경학회지, 1(2), pp.144~155 (2005), 한국실내환경학회
  15. 환경부, "다중이용시설 등의 실내공기질관리법", ~ (2010)
  16. Kim, S.-M., , Indoor Air 2005, 15, pp.317~325 (2005)
  17. Kelly, T. J., , Environmental Science Technology, 33, pp.81~88 (1999)
  18. Maroni M., "Indoor air quality - a comprehensieve reference book" (1992), Elsevier
  19. Nazaroff W.W., , Indoor Air 2001, 11, pp.143~144 (2001)
  20. 환경부, "실내공기질공정시험기준", ~ (2010)

관련 논문AI추천